E100-11xx -05 Title BD unlock error
Detection description
Locked state was not detected within the specified period of time at start-up.
Remedy 1. Check if the door is opened. Close the door.
2. Check the connection between the DC Controller PCB (PCB1) and the Laser Driver PCB (PCB35).DC Controller side: J471, J472, Laser Driver side: J5100,J5101, Relay Harness connection to Polygon Motor and BD PCB: J3011
3. Replace the Laser Scanner Unit.
4. Replace the Laser Driver PCB (PCB35).
5. Replace the DC Controller PCB (PCB1).
NOTE:
When condensation occurs inside of the machine or the Laser Scanner Unit, this error also occurs.When condensation occurs, leave the machine or the unit as it is until condensation disappears. (Use the machine or the unit in an environment where condensation does not occur.)
E100-12xx -05 Title BD unlock error
Detection description
After the BD range was specified, lock was unlocked for 1 second or longer.
Remedy 1. Check if the door is opened. Close the door.
2. Check the connection between the DC Controller PCB (PCB1) and the Laser Driver PCB (PCB35).DC Controller side: J471, J472, Laser Driver side: J5100,J5101, Relay Harness connection to Polygon Motor and BD PCB: J3011
3. Replace the Laser Scanner Unit.
4. Replace the Laser Driver PCB (PCB35).
5. Replace the DC Controller PCB (PCB1).
NOTE:When condensation occurs inside of the machine or the Laser Scanner Unit, this error also occurs.When condensation occurs, leave the machine or the unit as it is until condensation disappears. (Use the machine or the unit in an environment where condensation does not occur.)
E100-13xx -05 Title Polygon Motor BD unlock error (Laser diode is not lit up/failure
of the BD PCB/power supply error, or condensation)
Detection description During the Polygon speed change, lock was unlocked for 1
second or longer. (Laser diode is not lit up/failure of the BD PCB/power supply error, or condensation)
Remedy 1. Check if the door is opened. Close the door.
2. Check the connection between the DC Controller PCB (PCB1) and the Laser Driver PCB (PCB35).DC Controller side: J471, J472, Laser Driver side: J5100,J5101, Relay Harness connection to Polygon Motor and BD PCB: J3011
3. Replace the Laser Scanner Unit.
4. Replace the Laser Driver PCB (PCB35).
5. Replace the DC Controller PCB (PCB1).
NOTE:When condensation occurs inside of the machine or the Laser Scanner Unit, this error also occurs.When condensation occurs, leave the machine or the unit as it is until condensation disappears. (Use the machine or the unit in an environment where condensation does not occur.)
E100-FFFF -05 Title Polygon Motor BD unlock error
Detection description Failed to get the Detailed Code (communication error, power
supply error, PCB failure, etc.).
Remedy 1. Check if the door is opened. Close the door.
2. Check the connector connection, open circuit, and the caught cable of the DC Controller PCB (PCB1) and the Laser Driver PCB (PCB35).DC Controller side: J471, J472, Laser Driver side: J5100,J5101, Relay Harness connection to Polygon Motor (M44) and BD Sensor: J3011
3. Replace the Laser Scanner Unit.
4. Replace the Laser Driver PCB (PCB35).
5. Replace the DC Controller PCB (PCB1).
E102-0001 -05 Title EEPROM writing error
Detection description
Failed to write to EEPROM (Power is not supplied/EEPROM failure).
Remedy 1. Check if the door is opened. Close the door.
2. Check the connector connection, open circuit, and the caught cable of the DC Controller PCB (PCB1) and the Laser Driver PCB (PCB35).DC Controller side: J471, J472, Laser Driver side: J5100,J5101, Relay Harness connection to Polygon Motor (M44) and BD Sensor: J3011
3. Replace the Laser Scanner Unit.
4. Replace the Laser Driver PCB (PCB35).
5. Replace the DC Controller PCB (PCB1).
E103-0001 -05 Title Different Laser Scanner Unit model error
Detection description The scanner for 6275/6265/6255 models was installed to the
imageRUNNER ADVANCE 8205/8295/8285 models, and vice versa.
Remedy Replace the Laser Scanner Unit with the one for the correct model.
E110-11xx -05 Title Polygon Motor FG unlock error
Detection description Locked state was not detected within the specified period of
time at start-up. (Power is not supplied/Polygon Motor signal error)
Remedy 1. Check if the door is opened. Close the door.
2. Check the connector connection, open circuit, and the caught cable of the DC Controller PCB (PCB1) and the Laser Driver PCB (PCB35).DC Controller side: J471, J472, Laser Driver side: J5100,J5101, Relay Harness connection to Polygon Motor (M44) and BD Sensor: J3011
3. Replace the Laser Scanner Unit.
4. Replace the Laser Driver PCB (PCB35).
5. Replace the DC Controller PCB (PCB1).
E110-12xx -05 Title Polygon Motor FG unlock error
Detection description After the BD range was specified, lock was unlocked for 1
second or longer. (Power is not supplied/Polygon Motor signal error)
Remedy 1. Check if the door is opened. Close the door.
2. Check the connector connection, open circuit, and thecaught cable of the DC Controller PCB (PCB1) and the Laser Driver PCB (PCB35).DC Controller side: J471, J472, Laser Driver side: J5100,J5101, Relay Harness connection to Polygon Motor (M44) and BD Sensor: J3011
3. Replace the Laser Scanner Unit.
4. Replace the Laser Driver PCB (PCB35).
5. Replace the DC Controller PCB (PCB1).
E110-13xx -05 Title Polygon Motor FG unlock error
Detection description During the Polygon speed change, lock was unlocked for 1
second or longer. (Power is not supplied/Polygon Motor signalerror)
Remedy 1. Check if the door is opened. Close the door.
2. Check the connector connection, open circuit, and the caught cable of the DC Controller PCB (PCB1) and the Laser Driver PCB (PCB35).DC Controller side: J471, J472, Laser Driver side: J5100,J5101, Relay Harness connection to Polygon Motor (M44)and BD Sensor: J3011
3. Replace the Laser Scanner Unit.
4. Replace the Laser Driver PCB (PCB35).
5. Replace the DC Controller PCB (PCB1).
E110-FFFF -05 Title Polygon Motor FG unlock error
Detection description Failed to get the Detailed Code (communication error, power
supply error, PCB failure).
Remedy 1. Check if the door is opened. Close the door.
2. Check the connector connection, open circuit, and the caught cable of the DC Controller PCB (PCB1) and the Laser Driver PCB (PCB35).DC Controller side: J471, J472, Laser Driver side: J5100,J5101, Relay Harness connection to Polygon Motor (M44) and BD Sensor: J3011
3. Replace the Laser Scanner Unit.
4. Replace the Laser Driver PCB (PCB35).
5. Replace the DC Controller PCB (PCB1).
E121-0001-05 Title Laser Scanner Cooling Fan error
Detection description The Fan stop signal is detected for 5 seconds or longer and
retry is failed 4 times in a row although the Laser Scanner Cooling Fan (FM16) is turned ON.
Remedy 1. Check the connection of the Connector.
2. Replace the Laser Scanner Cooling Fan (FM16).
E197-0001 -05 Title Error in Main Driver PCB connection detection
Detection description Failed to establish a communication between the DC
Controller PCB (PCB1) and the Main Driver PCB (PCB2).
Remedy 1. Check the connection of the DC Controller PCB (PCB1) and the Main Driver PCB (PCB2).DC Controller side: J411, J412, Main Driver side: J125,J126
2. Check the Main Driver PCB (PCB2) power supplyconnection. Check the connection at the Main Driver side (J128) and the DC Controller side (J414), and check the voltage.
3. Replace the Main Driver PCB (PCB2).
4. Replace the DC Controller PCB (PCB1).
E197-0002 -05 Title Error in Feed Driver PCB connection detection
Detection description Failed to establish a communication between the DC
Controller PCB (PCB1) and the Feed Driver Pub (PCB3).
Remedy 1. Check the connection of the DC Controller PCB (PCB1)
and the Feed Driver PCB (PCB3).DC Controller side: J421, Feed Driver side: J204
2. Check the connection of the Feed Driver PCB (PCB3) and the DC-DC Converter PCB.
Check the connection at the Feed Driver side (J218) and the DC-DC Converter side (J9033).
3. Check the power supply of the Feed Driver PCB (PCB3).
Check if appropriate voltages are applied to the Feed Driver
side (12 V to 1pin, 5 V to 3pin, 3.3 V to 4pin). -> If not,replace the DC-DC Converter PCB.
4. Replace the Feed Driver PCB (PCB3).
5. Replace the DC Controller PCB (PCB1).
E197-0003 -05 Title Error in Duplex Driver PCB connection detection
Detection description Failed to establish a communication between the DC
Controller PCB (PCB1) and the Duplex Driver PCB (PCB4).
Remedy 1. Check the connection between the DC Controller PCB (PCB1) and the Fixing Feed Drawer.DC Controller side: J431, J432, Fixing Feed Drawer (host machine side): J3002D
Fixing Feed Drawer (Fixing Feed side): J3002L, Duplex Driver side: J300, J301
2. Check the connection of the Duplex Driver PCB (PCB4) and the DC-DC Converter PCB.
Check the connection at the Duplex Driver side (J311) and the DC-DC Converter side (J9034).
3. Check the power supply of the Duplex Driver PCB (PCB4).
Check if appropriate voltages are applied to the Duplex Driver side (12 V to 1pin, 5 V to 3pin, 3.3 V to 4pin). -> If not, replace the DC-DC Converter PCB.
4. Replace the Duplex Driver PCB (PCB4).
5. Replace the DC Controller PCB (PCB1).
E197-0004 -05 Title Error in Relay PCB connection detection
Detection description
Connection between the DC Controller PCB (PCB1) and the Relay PCB (PCB5) is disconnected.
Remedy 1. Check the connection of the DC Controller PCB (PCB1) and the Relay PCB (PCB5).
DC Controller side: J451, Relay side: J514
2. Replace the Relay PCB (PCB5).
3. Replace the DC Controller PCB (PCB1).
E197-0005 -05 Title Error in Main Driver PCB Analog Connector connection
Detection description Connection between the DC Controller PCB (PCB1) and the
Main Driver PCB (PCB2) is disconnected.
Remedy 1. Check the connection of the DC Controller PCB (PCB1) and the Main Driver PCB (PCB2).DC Controller side: J413, Main Driver side: J124
2. Replace the Main Driver PCB (PCB2).
3. Replace the DC Controller PCB (PCB1).
E197-0006 -05 Title Error in Feed Driver PCB Drawer Connector connection
Detection description Connection between the DC Controller PCB (PCB1) and the
Feed Driver PCB (PCB3) is disconnected.
Remedy 1. Check the connection between the DC Controller PCB (PCB1) and the Fixing Feed Drawer.DC Controller side: J431, J432, Fixing Feed Drawer (host machine side): J3002D
Fixing Feed Drawer (Fixing Feed side): J3002L, Feed Driver side: J300, J301
2. Replace the Feed Driver PCB (PCB3).
3. Replace the DC Controller PCB (PCB1).
E197-0008 -05 Title Error in Fixing Drawer Connector connection detection
Detection description Connection between the DC Controller PCB (PCB1) and the
Main Driver PCB (PCB2) is disconnected.
Remedy 1. Check the connection between the Main Driver PCB (PCB2) and the Fixing Drawer.
Main Driver side: J105, Fixing Drawer (host machine side): J3001D
Check the Harness of the Fixing Drawer (Fixing side) (J3001L).
2. Replace the Main Driver PCB (PCB2).
E197-0009 -05 Title Error in the Process Unit connection detection
Detection description
Connection between the Main Driver PCB (PCB2) and the Process Unit is disconnected.
Remedy 1. Check the connection between the Main Driver PCB (PCB2) and the Process Unit.
PCB side: J107, Process Unit side: J3060
2. Replace the Process Unit.
E197-0010 -05 Title Error in Primary Charging High Voltage PCB connection
Detection description Connection between the Main Driver PCB (PCB2) and the
Primary Charging High Voltage PCB (PCB11) is disconnected.
Remedy 1. Check the connection between the Main Driver PCB (PCB2) and the Primary Charging High Voltage PCB (PCB11).Main Driver side: J111, Primary Charging High Voltage side: J3501
2. Replace the Primary Charging High Voltage PCB (PCB11).
E197-0011 -05 Title Error in Developing High Voltage PCB connection detection
Detection description Connection between the Main Driver PCB (PCB2) and the
Developing High Voltage PCB (PCB12) is disconnected.
Remedy 1. Check the connection between the Main Driver PCB (PCB2) and the Developing High Voltage PCB (PCB12).Main Driver side: J112, Developing High Voltage side: J3511
2. Replace the Developing High Voltage PCB (PCB12).
E197-0012 -05 Title Error in Transfer High Voltage PCB connection detection
Detection description Connection between the Duplex Driver PCB (PCB4) and the
Transfer High Voltage PCB (PCB13) is disconnected.
Remedy 1. Check the connection between the Duplex Driver PCB (PCB4) and the Transfer High Voltage PCB (PCB13).Duplex Driver side: J343, Transfer High Voltage side: J3062
2. Replace the Transfer High Voltage PCB (PCB13).
E197-0181 -05 Title Serial communication error
Detection description Failure of reception from the video signal control ASIC.
Data reception was failed 5 times in a row when reading data
from the video signal control ASIC (at FG lock detection, BD lock detection).
Remedy Replace the DC Controller PCB (PCB1).
E199 -0000 -05 Title -
Detection description -
Remedy Collect the sublog and contact the sales company.



Thousands of Parts and Free Shipping



 

No comments: