Durables and Consumables Spare Parts for Canon IR 2016 2020 2318 2420


 Ref. Parts name                Parts No. Q'ty Life Remarks
[1] Manual feed pickup roller  FL2-3202-000 1  150K
[2] Manual feed separation pad FL2-3201-000 1  150K
[3] Devrloping unit            FM2-3286-000 1  150K
[4] Transfer roller            FC6-4313-000 1  150K
[5] Fixing unit (120V)         FM2-3345-000 1  150K
Fixing unit (230V)             FM2-3352-000 1  150K

http://www.partstron.com

Sunday, January 8, 2017

Consumable Spare Parts For Canon IRV 8105 8095 8085 8205 8295 8285

http://www.partstron.com

Parts NameParts Number Piece Expected life* COUNTER

Right Deck   Pickup Roller FC5-2524 1 50 C1-PU-RL
Right Deck   Feed Roller FC5-2526 1 50 C2-PU-RL
Right Deck   Separation Roller FC5-2528 1 50 C1-FD-RL
Left Deck    Pickup Roller FC5-2524 1 50 C2-FD-RL
Left Deck    Feed Roller FC5-2526 1 50 C1-SP-RL
Left Deck    Separation Roller FC5-2528 1 50 C2-SP-RL
Cassette 3   Pickup Roller FC5-2524 1 50 C3-PU-RL
Cassette 3   Feed Roller FC5-2526 1 50 C3-FD-RL
Cassette 3   Separatio n Roller FC5-2528 1 50 C3-SP-RL
Cassette 4   Pickup Roller FC5-2524 1 50 C4-PU-RL
Cassette 4   Feed Roller FC5-2526 1 50 C4-FD-RL
Cassette 4   Separation Roller FC5-2528 1 50 C4-SP-RL
Multi-purpose  Tray Separation Roller FB1-8581 1 12 M-FD-RL
Multi-purpose  Tray Feed Roller FC6-6661 1 12 M-SP-RL

Wednesday, January 4, 2017

Error Code Table E001 E002 E003 E007...... For Canon IR 4570 3570 2870 2270




http://www.partstron.com

Code Error name/description
E000 fixing overheating
E001 fixing assembly overheating
E002 fixing assembly low temperature
E003 post-standby fixing low temperature
E007 fixing film rotation error
E010 main motor rotation error
E014 fixing motor rotation error
E019 waste toner case full, waste toner case full sensor error
E020 toner clogging between sub hopper and developing assembly
E024 developing assembly connector disconnection
E025 hopper motor, bottle motor error
E032 NE controller counter error
E064 power supply voltage error (high-voltage)
E100 BD interval error
E110 scanner motor error
E191 communication error for high voltage power supply
E202 CIS home position detection error
E225 CIS light intensity error
E227 reader unit power supply error
E248 backup memory error
E261 zero-cross signal error
E315 image data error
E400 feeder communication error

Monday, January 2, 2017

Error Code

E000 E001 E002 E007

for Canon iR2016J   iR2016   iR2020 iR2016i  iR2020i

http://www.partstron.com


Error Code Detail  Code Error Name/Explanation of Error
E000 0000 Fixing temperature abnormal rise
E001
0000 Fixing unit temperature rise detection (by main thermistor)
0001 Fixing unit temperature rise detection (by sub thermistor)
E002 0000 Fixing unit temperature insufficient rise
E003
0000 Low fixing temperature detection after standby (by main thermistor)
0001 Low fixing temperature detection after standby (by sub thermistor)
E007 0000 Fixing film rotation error
E010 0000 Main motor rotation error
E019
0001 Waste toner full detection
0002 Waster toner full detection sensor failure
E052 0000 Duplex unit connection error
E100 0000 BD cycle out of range
E197 0000 Erroneous communication with printer engine
E500 0001 Finisher communication error
E520 0000 Offset error
E531 0000 Stapling error
E540
0001 Paper surface not detected (standard tray)
0002 Not moved within the specified time (standard tray)
0003 Sensor not reached within 3 seconds (standard tray)
0005 Encoder clock failure (standard tray)
E542
0001 Paper surface not detected (optional tray)
0002 Not moved within the specified time (optional tray)
0003 Sensor not reached within 3 seconds (optional tray)
0005 Encoder clock failure (optional tray)
E575 0000 Stack delivery error
E584 0000 Shutter failure
E716 0000 Erroneous communication with optional cassette
E719
0000 Erroneous communication with card reader (serial communication)
0002 Erroneous communication with coin vender (serial communication)
E733 0000 Erroneous communication between controller and printer
E736 0000 CCU communication error
E739 0000 Erroneous communication between controller and network board
E805 0000 Fan failure
E808 0000 Fixing drive circuit failure