Wednesday, April 30, 2014

Errorcodes E711 To E749 for Canon ImageRunner 7105/7095/7086



E711 An error has occurred in the communication between the pickup/delivery accessory and the printer unit.
0001 The communication controller has detected a fault.

Turn off and then back on the power. (Turn off the machine and its delivery accessories; then, turn back on all accessories and then the machine.)
Connect the communication cables and terminals between the machine and the delivery accessories once again.
Replace the accessories controller PCB. Replace the transceiver PCB.
E712 An error exists in the communication between the ADF and the reader unit .
0001 As much as 5 sec or more has passed without recovery after communicationstopped
between the reader controller and the ADF controller.

Disconnect and then connect the connectors between the reader unit and the ADF. Replace
the reader controller PCB. Replace the ADF controller PCB.
E717 An error exists in the communication with the NE controller.
After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
0001 The NE controller that has been connected before power-off is not recognized at power-on.
0002 In the communication with the coin vendor, an error that cannot be reset has occurred (e.g.,cable break).

Disconnect and then connect the main controller PCB. Install the NE controller. Replace the NE controller.
E719 An error has occurred in the communication with the coin vendor/card reader.
After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
0001 The coin vendor that was connected before power-off is not recognized at power-on.
0002 In the communication with the coin vendor, an error that cannot be reset has occurred (e.g., cable break).
0003 In the communication with the coin vendor, a communication error has occurred during acquisition of unit price information.

Disconnect and then connect the connector of the main controller PCB. Install the coin vendor.
Replace the coin vendor.

0011 The card reader that was connected before power-off is not recognized at power-on.
0012 In the communication with the card reader, an error that cannot be reset has occurred (e.g., cable break).
Disconnect and then connect the connector of the main
controller PCB. Install the card reader.Replace the card reader.
E730 A PDL-related error has occurred.
1001 An initialization error has occurred at the start of a job.
100A An error has occurred in the communication with an external controller.
Reset the PDL mechanism. Turn off and then on the power.

9004 A fault has been detected in the cable connection with an external controller.
9005 A fault has been detected in the cable connection with an external controller.
Turn off and then on the power. Replace the external
controller relay PCB. Replace the external controller.

A006 The PDL mechanism does not respond. Reset the PDL mechanism.
Turn off and then on the power. Reinstall the system software. Replace the main controller.

A007 At start-up, the version of the machine control software and that of the PDL control software do not match.
Reset the PDL mechanism. Turn off and then on the power. Execute full formatting of the
HDD, and reinstall the system software.

B013 The font data is corrupted at start-up.
Turn off and then on the power. Reinstall the system software. Execute full formatting of
the HDD, and reinstall the system software.

E732 An error has occurred in the communication between the reader unit and the main controller.
0001 An error has occurred in the communication between the reader unit and the main controller.
0010 A fault has been detected in the reader sync signal detection mechanism.
Disconnect and connect the connectors of the read communication cable. Check the
power supply of the reader unit (to see if initialization occurs at power-on). Replace the
reader controller PCB. Reap the reader I/F PCB. Replace the main controller PCB.

E733 An error has occurred in the communication between the reader unit and the main controller.
0000 An error has occurred in the communication between the reader unit and the main controller.
0001 An attempt to communicate with the DC controller fails.
0010 A fault has occurred in the printer engine sync signal detection mechanism.
Disconnect and then connect the connector. Check the power supply of the DC controller (to
see if initialization occurs at time of start-up). Replace the DC controller PCB. Replace the
main controller PCB.

E740 An error exists in the LAN controller .
0002 An illegal MAC address has been detected at start-up.
Replace the main controller PCB.

E743 A fault exists in the communication between the main controller and the reader controller.
0000 The reader controller has detected an error in the communication between the main controller and the reader controller.
Disconnect and then connect the connectors of the reader
communications cable. Replace the reader controller PCB. Replace the main controller PCB.

E744 An error exists in the language file/boot ROM.
0001 The version of the language file on the HDD and that of bootable do not match.
0002 The language file on the HDD is too large.
0003 There is no language to which a switchover is made as described in the Config file on the HDD.
0004 An attempt to switch over to the language described in the Config file on the HDD fails.
Update the version of the language file (Language), or install the appropriate file.

1000 The connected boot ROM is not one designed for the model in question.
Replace the boot ROM.

2000 An illegal engine ID has been detected.
Reinstall the system software.

E746 An unsupported optional board has been detected.
0003 The option board that has been detected is one deigned for a different model.
Replace it with one for the model in question.

E749 Restart in accordance with a change of the product configuration .
0001 A boot ROM designed for a different model has been fitted in place (as when installing an PDL option).
There is no need for remedial action. Nevertheless, the fact
will remain as part of the
error history.

Thousands of Parts and Free Shipping


 

No comments:

Post a Comment