Tuesday, April 29, 2014

Errorcodes E000 To E010 and solution for Canon ImageRunner 7105/7095/7086


E000 The fixing unit has overheated.

After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
0000 The reading of the main thermistor is less than 70 deg C 3.5 min after poweron.
Check the mounting/soiling of the main thermistor.
Replace the fixing heater.Replace the main thermistor.
Replace the AC driver PCB.Replace the DC controller PCB
.0010 The power has been turned off and then on without resetting the error. Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
E001 The fixing unit has overheated. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)0001 The reading of the main thermistor or the sub thermistor is 230 deg C or more for 2 sec. (hardware detection)
Replace the AC driver PCB.Replace the DC controller PCB.
0002 The reading of the main thermistor or the sub thermistor is 230 deg C or more for 2 sec or more. (software detection)
Check the mounting/soiling of the main thermistor.
Replace the main thermistor.Replace the sub thermistor.
Replace the AC driver PCB.Replace the DC controller PCB.
0003 The difference in the readings of the main thermistor and the sub thermistor is 50 deg C for 1 sec. (main thermistor reading>sub thermistor reading)
Check the mounting/soiling of the main thermistor.Replace the main thermistor.
Replace the AC driver PCB.
Replace the DC controller PCB.0004 The difference in the readings of the main thermistor and the sub thermistor is 50 deg C for 1 sec or more. (main thermistor reading>/=sub thermistor reading)
Check the mounting/soiling of the main thermistor.
Replace the main thermistor.
Replace the AC driver PCB.
Replace the DC controller PCB.0010 The power has been turned off and then on without resetting the error.
Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
E002 The fixing unit has overheated. After correcting the error, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)0000 The reading of the main thermistor has exceeded 70 deg C, but does not reach 100 deg C within 2.5 sec thereafter.
Disconnect and then connect J508 of the DC controller PCB.Disconnect and then connect the connectors of the fixing unit.
Check the wiring between the main/sub thermistor and the DC controller. Check the mounting/soiling of the main thermistor.
Replace the fixing heater.Replace the AC driver PCB.Replace the DC controller PCB.
0001 The reading of the main thermistor has exceeded 100 deg C, but does not reach 150 deg C within 2.5 min thereafter.
Disconnect and then connect J508 of the DC controller PCB.Disconnect and then connect the connectors of the fixing unit.
Check the wiring between the main/sub thermistor and the DC controller. Check the mounting/soiling of the main thermistor.
Replace the fixing heater.Replace the AC driver PCB.Replace the DC controller PCB.
0010 The power has been turned on without resetting the error.
Reset the error. (COPIER>FUNCTION>CLEAR>ERR).
E003 The fixing unit temperature is abnormally low. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)0000 The reading of the main thermistor has exceeded 100 deg C, but is 70 deg C or less for 2 sec thereafter.
Disconnect and then connect J508 of the DC controller PCB.
Disconnect and then connect the connectors of the fixing unit. Check the wiring between the main/sub thermistor andthe DC controller PCB. Check the mounting/soiling of the main thermistor.
Replace the fixing heater.
Replace the AC driver PCB.
Replace the DC controller PCB.
E004 The fixing unit has a fault. (protective circuit ON) After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)0000 While the sub heater is on, the SSR for the heater drive has a short-circuit for 5 sec or more.
Replace the AC driver PCB.
Replace the DC controller PCB.0001 While the main heater is on, the SSR for the heater drive has a short-circuit for 5 sec or more.
E005 The fixing web has run out. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR).
0000 The absence of the fixing web has been detected for 5 sec or more.
Check the position of the fixing web detecting lever.
Replace the fixing web.Replace the fixing web length sensor.
Replace the DC controller PCB.
If you have replaced the fixing web, be sure to reset the counter:- COPIER>COUNTER>MISC>FIX-WEB
- COPIER>COUNTER>DRBL-1>FX-WEB
E010 The main motor rotation is faulty. 0000 After the main motor has gone on, the FG signal of the motor is not detected for 2 sec or more.Disconnect and then connect J611 and J612 of the main motor.
Disconnect and then connect J514 of the DC controller PCB.
Disconnect and then connect J1720 of the relay PCB.
Replace the main motor.Replace the relay PCB.Replace the DC controller PCB.



Thousands of Parts and Free Shipping



 

No comments:

Post a Comment