Wednesday, April 30, 2014

Errorcodes E302 To E610 For ImageRunner 7105/7095/7086

 

 

E302 Shading operation is faulty.

0000 In the course of shading operation, the processing doses not end within thereader controller.
Disconnect and then connect J1107 and J1108 of the reader controller PCB.
Replace the reader controller PCB.
E315 The image data codec has a fault.
0007 A JBIG encoder error has occurred.
Replace the main controller PCB.
000d A JBIG decoding error has occurred .
000e An error has occurred in the course of software decoding .
Replace the DDR-SDRAM. Replace the HDD.Replace the main controller PCB
0100 An overrun error has occurred
Replace the main controller PCB.
0200 the open I/F relay PCB has detected an error (no recovery after a retry).
Replace the open I/F relay PCB (relay PCB between the main controller and PS controller).
0300 Cubic time-out Turn off and then back on he power. .
0400 Shift Device A time-out.
0401 Shift Device B time-out
Replace the main controller PCB
E351 An error has occurred in the main controller communication.
0000 At start-up, a main controller communication error has occurred.
Replace the main controller PCB.
E400 ** An ADF communication error has occurred.0001 A check sum error has occurred. Disconnect and then connect the connector. 0002 A reception status error has occurred.
0003 A reception interrupt error has occurred.
Replace the reader controller PCB. Replace the ADF controller PCB.
E402 * The ADF belt motor rotation is faulty .
0000 While the belt motor drive signal is on, no lock signal occurs for 100 msec.
Disconnect and then connect the cable between the belt motor driver PCB and the ADF controller PCB.
Replace the belt motor clock sensor. Replace the belt motor clock sensor.
Replace the belt motor. Replace the belt motor driver PCB.Replace the ADF controller PCB.
E404 * The ADF delivery motor rotation is faulty .
0000 When the delivery motor drive signal is on, no clock signal occurs for 200 msec.
Replace the delivery motor. Replace the delivery motor clock sensor. Replace the ADF controller PCB.
E405 * The ADF separation motor rotation is faulty .
0000 When the separation motor drive signal is on, no clock signal occurs for 200 msec.
Replace the separation motor. Replace the separation motor clock sensor. Replace the ADF controller PCB.
E410 * The ADF pickup motor rotation is faulty .
0000 No signal occurs from the following sensors within 2 sec after the pickup motor is driven:
- pickup roller height sensor 1 (PI8), pickup roller height sensor 2 (PI9)
- pickup roller HP sensor (PI7)
Replace the pickup motor. Replace the pickup roller height sensor (PI8). Replace the pickup
roller height sensor 2 (PI9). Replace the pickup roller HP sensor (PI7). Replace the ADF controller PCB.
E413 ** The ADF shift motor rotation is faulty .
0001 The shift motor HP sensor is open. 0002 Shift motor HP sensor is closed.
Disconnect and then connect the connector. Replace the shift motor HP sensor. Replace the shift motor.
E420 * An ADF EEPROM read error has occurred .
0000 At power-on, an attempt to read the EEPROM backup data fails. Or, data that has been read has a fault.
Replace the ADF controller PCB.
E490 The ADF is of the wrong type.
0001 The ADF is of the wrong type.
Replace the ADF.
E602 The HDD has an error.
E604 The time memory (DDR-SDRAM) is faulty or inadequate.
0000 A DDR-SDRAM (1 GB) of adequate capacity is not detected.
Replace the DDR-SDRAM.
E609 The HDD temperature is abnormally low.
0008 At start-up, the HDD does not reach a specific temperature within a specific time.Replace the HDD.
0009 When returning from sleep mode, the HDD does not reach a specific temperature within a specific time.
Replace the HDD.
E610 The HDD encryption key is faulty.
0001 The memory is missing.Install the security board.
0002 The memory is inadequate.
Replace the DDR-SDRAM with one for the model in question (1 GB).
0101 An attempt to initialize the key storage area of the memory has failed. Turn off and then on the power.
Replace the main controller PCB.
0102 An error has occurred while the encryption processing area is being initialized.
Turn off and then on the power. Replace the security board.
0201 An error has occurred in the encryption processing area.
0202 An error has occurred in the encryption processing area.
0301 An attempt to create an encryption key has failed.
Turn off and then on the power. Replace the security board.
0302 A fault exists in the encryption key. .
0303 A fault exists in the encryption key. PCB.
Turn off and then on the power. Replace the main controller PCB.
0401 An error has been detected during coding. Turn off and then on the power .
0402 A fault has been detected in decoding.
0501 An error exists in the file management information in the image storage area.

Turn off and then on the power. Replace the security board.