Monday, May 12, 2014

Canon ImageRunner Advance 8205 8295 8285,Errorcode E000 To E005 and Solution

 


http://www.partstron.com 
E000 -0001 -05 Title Fixing Assembly low temperature error
Detection description Temperature of the Fixing Main Thermistor (THM1) does
not reach 70 degC although 35 seconds have passed after starting the Fixing Roller temperature control.
Remedy 1. Check the connection of the Fixing Assembly. (Connection
error of the Drawer, connector disconnection, open circuit) -> Replace the Heater Assembly.
2. Check the connection between the Main Driver PCB (PCB2) and the Fixing Power Supply PCB (PCB10) (connector disconnection, open circuit, the caught cable).
3. Replace the Fixing Power Supply PCB (PCB10).
4. Replace the Main Driver PCB (PCB2).
5. Replace the DC Controller PCB (PCB1).
E000 -0002 -05 Title Fixing Assembly low temperature error
Detection description Temperature of the Fixing Main Thermistor (THM1) does
not reach 10 degC although 35 seconds have passed after starting the Fixing Roller temperature control.
Remedy 1. Check the connection of the Fixing Assembly. (Connection error of the Drawer, connector disconnection, open circuit)-> Replace the Heater Assembly.
2. Check the connection between the Main Driver PCB (PCB2) and the Fixing Power Supply PCB (PCB10) (connector disconnection, open circuit, the caught cable).
3. Replace the Fixing Power Supply PCB (PCB10).
4. Replace the Main Driver PCB (PCB2).
5. Replace the DC Controller PCB (PCB1).
E000 -0010 -05 Title Fixing Assembly low temperature error
Detection description
Turning OFF and then ON the power without clearing the error.
Remedy Clear the error.
E001 -0002 -05 Title Fixing Assembly high temperature error (software detection)
Detection description • The Fixing Main Thermistor (THM1) detects 230 degC or
higher. • The Fixing Sub Thermistor 1 (THM2)/Fixing Sub Thermistor
2 (THM4) detects 230 degC or higher for 2 consecutive seconds.
Remedy 1. Check if the cable of the Thermistor is caught. -> Replace the Thermistors. -> Replace the Fixing Upper Unit.
2. IH control error. -> Replace the Fixing Power Supply PCB (PCB10), the DC Controller PCB (PCB1), or the Main Driver PCB (PCB2).
E001 -0003 -05 Title Fixing Assembly high temperature error (hardware detection)
Detection description • The Fixing Main Thermistor (THM1) detects hardware overheating.
• The Fixing Sub Thermistor 1 (THM2)/Fixing Sub Thermistor
2 (THM4) detects hardware overheating. Remedy 1. Check if the cable of the Thermistor is caught. -> Replacethe Thermistors. -> Replace the Fixing Upper Unit.
2. Replace the Main Driver PCB (PCB2).
3. Replace the DC Controller PCB (PCB1).
E001 -0004 -05 Title Fixing Assembly high temperature error (hardware detection)
Detection description Abnormal temperature difference among the Thermistors was
detected.
Remedy 1. Check if the cable of the Thermistor is caught or is open
circuit. -> Replace the Thermistors. -> Replace the Fixing Upper Unit.
2. Replace the Main Driver PCB (PCB2).
3. Replace the DC Controller PCB (PCB1).
E001 -0010 -05 Title Fixing Assembly high temperature error
Detection description
Turning OFF and then ON the power without clearing the error.
Remedy Clear the error
E002 -0001 -05 Title Fixing Assembly temperature rise error
Detection description • Temperature of the Fixing Main Thermistor (THM1) does not
reach 100 degC although 25 seconds have passed since it reached above 70 degC after starting the Fixing Roller temperature control.
• Temperature of the Fixing Main Thermistor does not reach 130 degC although 25 seconds have passed since it reached above 100 degC after starting the Fixing Roller
temperature control.
• Temperature of the Fixing Main Thermistor does not reach 150 degC although 20 seconds have passed since it reached above 130 degC after starting the Fixing Roller
temperature control.
Remedy 1. Check the connection of the Fixing Main Thermistor (THM1).
-> Replace the Fixing Main Thermistor Unit.
2. Check the installation of the Fixing Main Thermistor. ->
Replace the Fixing Upper Unit.
3. Replace the Fixing Power Supply PCB (PCB10).
4. Replace the Main Driver PCB (PCB2).
5. Replace the DC Controller PCB (PCB1).
6. Replace the Relay PCB (PCB5).
E002 -0010 -05 Title Fixing Assembly temperature rise error
Detection description Turning OFF and then ON the power without clearing the error.
Remedy Clear the error.
E003 -0000 -05 Title Fixing Assembly temperature decrease error
Detection description The Fixing Main Thermistor (THM1) detects 70 degC or lower
for 2 seconds or longer although the temperature reached above 100 degC after starting the Fixing Roller temperature control.
Remedy 1. Check the connection of the Fixing Main Thermistor (THM1).
-> Replace the Fixing Main Thermistor Unit.
2. Check the installation of the Fixing Main Thermistor. ->
Replace the Fixing Upper Unit.
3. Replace the Fixing Power Supply PCB (PCB10).
4. Replace the Main Driver PCB (PCB2).
5. Replace the DC Controller PCB (PCB1).
6. Replace the Relay PCB (PCB5).
E003 -0010 -05 Title Fixing Assembly temperature decrease error
Detection description Turning OFF and then ON the power without clearing the error.
Remedy Clear the error.
E004 -0010 -05 Title Fixing Power Supply error
Detection description
Turning OFF and then ON the power without clearing the error.
Remedy Clear the error.
E004 -0102 -05 Title Fixing Power Supply error
Detection description Fixing current error.
Remedy Replace the Fixing Power Supply PCB (PCB10). Replace the Main Driver PCB (PCB2).
E004 -0205 -05 Title Fixing Power Supply error
Detection description Detect that the Fixing Main Thermistor (THM1) is not connected.
Remedy 1. Check the harness of the Fixing Main Thermistor (THM1) in the Fixing Assembly.
2. Check the connection of the harness of the Fixing Assembly on the host machine side.
3. Replace the Main Driver PCB (PCB2).
E005 -0000 -05 Title Fixing Cleaning Web absent error
Detection description After noticing the Fixing Cleaning Web absent, the web was
pulled out 2000 times.
Remedy 1. Replace the Fixing Cleaning Web.
2. Replace the Fixing Cleaning Web Level Sensor (PS45).
3. Replace the DC Controller PCB (PCB1).
After executing the measures, clear the Fixing Cleaning Web
counter (COPIER> COUNTER> MISC> FIXWEB).
E005 -0001 -05 Title Error in Fixing Cleaning Web Drive Solenoid connection
Detection description Connection of the Fixing Cleaning Web Drive Solenoid (SL9)
is not detected when the power is turned ON.
Remedy 1. Check the Connector of the Fixing Cleaning Web Drive Solenoid.
2. Check the output of the DC Power Supply PCB (24V) (PCB31). Using a tester, check whether 24V is output from 3PIN through 6PIN of J513 on the Relay PCB. In case of error,
replace the DC Power Supply PCB (24V) (PCB31) (on the right).
3. Replace the Fixing Cleaning Web Drive Solenoid (SL9).
E005 -0010 -05 Title Fixing Cleaning Web error
Detection description Turning OFF and then ON the power without clearing the error.
Remedy Clear the error.


 




http://www.partstron.com

No comments:

Post a Comment