Sunday, May 4, 2014

Errorcode E023 To E069 and solution for Canon ImageRunner Advance 6255 6265 6275

Thousands of Parts and Free Shipping


 
E023-0001 -05 Title Developing Motor errorDetection description Lock error of the Developing Motor (M2).
Remedy 1. Check the connection of the Connector.Motor side: J2319, Main Driver PCB (PCB2) side: J109
2. Check the voltage of the Developing Motor (M2) J2152.
If voltage is 0V, check the connection of the Relay PCB J520.
3. Check the load of the Developing Motor (M2).Manually turn the Developing Motor (M2) located at the rear
of the host machine to check it.
4. Replace the Developing Motor (M2).
5. Replace the Developing Clutch (CL1). (When an error occurs while the Developing Clutch is ON.)
6. Replace the Main Driver PCB (PCB2).
7. Replace the DC Controller PCB (PCB1).
E023-0002 -05 Title Error in Magnet Roller Clutch connection detection
Detection description Connection of the Magnet Roller Clutch (CL5) cannot be
detected 5 times with 20 msec time interval.
Remedy 1. Check the connection of the Magnet Roller Clutch (CL5).
Sensor side: J2006, Main Driver PCB (PCB2) side: J109
2. Replace the Magnet Roller Clutch (CL5).
3. Replace the Main Driver PCB (PCB2).
4. Replace the DC Controller PCB (PCB1).
E025-0001 -05 Title Toner Feed Motor error
Detection description Overcurrent of the Toner Feed Motor (M28) was detected.
Remedy 1. Check the connection of the Connector. Motor side: J2036, Buffer Unit relay: J3124, Front side relay:
J3090, Rear side relay: J3091, Main Driver PCB (PCB2) side: J115
2. Replace the Toner Feed Motor (M28).
3. Check if toner is clogged inside of the Buffer.Turn the Drive Shaft of the Motor with your hand to check it.
If the load is too much, inside of the Buffer may be clogged, so clean inside of it.
4. Replace the Main Driver PCB (PCB2).
5. Replace the DC Controller PCB (PCB1).
E027-0001 -05 Title Toner Supply Motor error
Detection description Lock error of the Toner Supply Motor (M10).
Remedy 1. Check the connection of the Connector. Motor side: J2037, Front side relay: J3080, Rear side relay:
J3063, Main Driver PCB (PCB2) side: J117
2. Remove the Toner Container, and check if an error occurs.If an error does not occur, reinstall the Toner Container and check again. If an error occurs, check the driving area of connection point of the container.
If an error occurs, go on to 3.
3. Replace the Toner Supply Motor (M10).
4. Replace the Main Driver PCB (PCB2).
5. Replace the DC Controller PCB (PCB1).
E032-0001 00 Title Failure of NE Controller Counter
Detection description Detection of open circuit of count pulse signal.
Remedy Disconnection of cable.
E041-0001 -05 Title Right Deck Lifter Motor error
Detection description Overcurrent of the Right Deck Lifter Motor was detected.
Remedy 1. Check for displacement of the Lifter Wire of the Right Deck.
2. Check for hindrance to smooth movement of the Deck Base Plate of the Right Deck.
E041-0002 -05 Title Left Deck Lifter Motor error
Detection description Overcurrent of the Left Deck Lifter Motor was detected.
Remedy 1. Check for displacement of the Lifter Wire of the Left Deck.
2. Check for hindrance to smooth movement of the Deck Base Plate of the Left Deck.
E041-0003 -05 Title Cassette 3 Lifter Motor error
Detection description
Overcurrent of the Cassette 3 Lifter Motor was detected.
Remedy 1. Check for error around the Lifter of the Cassette 3.
2. Check for hindrance to smooth movement of the Cassette Base Plate of the Cassette 3.
E041-0004 -05 Title Cassette 4 Lifter Motor error
Detection description Overcurrent of the Cassette 4 Lifter Motor was detected.
Remedy 1. Check for error around the Lifter of the Cassette 4.
2. Check for hindrance to smooth movement of the Cassette Base Plate of the Cassette 4.
E053-0001 -05 Title Error in Reverse Upper Flapper Solenoid connection detection
Detection description Connection of the Reverse Upper Flapper Solenoid (SL5)
cannot be detected 5 times with 20 msec time interval.
Remedy 1. Check the connection of the Reverse Upper Flapper Solenoid (SL5).
Solenoid side: J2115, Duplex Driver PCB side: J340
2. Replace the Reverse Upper Flapper Solenoid (SL5).
3. Replace the Duplex Driver PCB (PCB4).
4. Replace the DC Controller PCB (PCB1).
E060-0001 -05 Title Primary Charging Shutter HP open error
Detection description
The Primary Charging Shutter Sensor (PS94) detects that the
shutter is opened although it is moved to the close position.
Remedy 1. Check the position of the Primary Charging Shutter and the Cleaning Pad.
1-A  In the case that the Primary Charging Shutter and theCleaning Pad fail to operate (stopped at HP at front side)
1-A-1 Check the connection of the Primary Charging Wire Cleaning Motor (M6). Motor side: J3017, J3060 (iR-ADV 8xxx)/J3160 (iRADV 6xxx) (relay), PCB side: J3177 (relay), J107 (Main Driver PCB (PCB2))
1-A-2.Replace the Primary Charging Wire Cleaning Motor (M6).1-B In the case that the Primary Charging Shutter and theCleaning Pad are stopped at rear side (close operation position)
1-B-1 Check the connection of the Primary Charging Shutter Sensor (PS94).Sensor side: J2029, J3089 (relay), PCB side: J3088 (relay), J114 (Main Driver PCB (PCB2))
1-B-2 Replace the Primary Charging Shutter Sensor (PS94).1-C In the case that the Primary Charging Shutter and the Cleaning Pad are stopped along the way1-C-1 Check the loosening of screw on the Slider Pinand abrasion of the pin. Tighten the screw or replace the Slider Pin.
1-C-2 Replace the Primary Charging Assembly.1-D In the case that the Primary Charging Shutter stops at front side and the Cleaning Pad moves to rear side
1-D-1 Check if the Shutter Mounting Plate is deformed.If so, replace the Shutter Unit.
1-D-2 Check the loosening of screw on the Slider Pin and abrasion of the pin. Tighten the screw or replace
the Slider Pin.
1-D-3 Replace the Primary Charging Assembly.2. Replace the Main Driver PCB (PCB2).
3. Replace the DC Controller PCB (PCB1).
E060-0002 -05 Title Primary Charging Shutter HP close error
Detection description The Primary Charging Shutter Sensor (PS94) detects that the
shutter is closed although it is moved to the open position.
Remedy 
Check the position of the Primary Charging Shutter and the Cleaning Pad.1-A In the case that the Primary Charging Shutter and the Cleaning Pad fail to operate (stopped at HP at front side)
1-A-1 Check the connection of the Primary Charging Wire Cleaning Motor (M6). Motor side: J3017, J3060 (iR-ADV 8xxx)/J3160 (iRADV6xxx) (relay), PCB side: J3177 (relay), J107 (Main Driver PCB (PCB2))
1-A-2 Replace the Primary Charging Wire Cleaning Motor (M6).1-B In the case that the Primary Charging Shutter and theCleaning Pad are stopped at rear side (close operation position)
1-B-1 Check the connection of the Primary Charging Shutter Sensor (PS94).Sensor side: J2029, J3089 (relay), PCB side: J3088 (relay), J114 (Main Driver PCB (PCB2))
1-B-2 Replace the Primary Charging Shutter Sensor (PS94).1-C In the case that the Primary Charging Shutter and the Cleaning Pad are stopped along the way
1-C-1 Check the loosening of screw on the Slider Pin and abrasion of the pin. Tighten the screw or replace the Slider Pin.
1-C-2 Replace the Primary Charging Assembly.2. Replace the Main Driver PCB (PCB2).
3. Replace the DC Controller PCB (PCB1).
E061-0101 -05 Title Potential control error (VD)
Detection description Potential in the dark area did not fall within the range (target
value +/-10 V) although retry was executed 8 times at VD potential control.
Remedy 1. Check the connection of the Pre-exposure LED (connector connection, open circuit, the caught cable).
2. If the current value of the Primary Charging Roller (COPIER>DISPLAY> DPOT> PRIM-C) is 1550 micro A or higher, execute 2-1 to 3.
2-1. Increase the grid voltage of the Primary Charging Assembly by 100V (COPIER> ADJUST> HV-PRI> PRI-GRID).
2-2. Execute the potential control (COPIER> FUNCTION> DPC> DPC).
2-3. Turn OFF and then ON the power.
3. Check the installation of the Primary Charging Assembly (connector connection, open circuit, the caught cable).
4. Check the installation of the Primary Charging High Voltage PCB (PCB11), and its connection (connector connection, open circuit, the caught cable).
5. Check the installation of the Drum Motor (M1), and its connection (connector connection, open circuit, the caught cable).
6. Replace the parts.
• Primary Charging Assembly
• Primary Charging High Voltage PCB
• Drum Motor (M1)
• Main Driver PCB (PCB2)
• DC Controller PCB (PCB1)
E064-00FF -05 Title High voltage setting error
Detection description With the state in which the developing AC is output, 600 V or higher developing DC output was detected.(Basically, this error is not detected. However, to detect that
the image formation-related backup data is corrupted or to
protect the hardware in case of 600 V or higher developing DC output, this is to be an error.)
Remedy 1. Turn OFF and then ON the main power.
2. Replace the DCON PCB.
E065-0001 -05 Title Primary charging/grid high voltage output leak error
Detection description
The leak detection signal was detected 5 times in a row for every 20 msec.
Remedy 1. Check the connection between the Main Driver PCB (PCB2)
and the High Voltage Unit.Main Driver side: J111, High Voltage Unit side: J3097
2. Check the connection between the Relay PCB (PCB5) and the High Voltage Unit.
Relay side: J519, High Voltage Unit side: J3099
3. Replace the Primary Charging Assembly.
4. Check the connection inside of the High Voltage Unit. High Voltage Unit Relay (J3097) and Primary Charging High Voltage PCB (PCB11) (J3501) High Voltage Unit relay (J3099) and Pre-transfer ChargingPCB (PCB26) (J3545, J3500)


5. Replace the Main Driver PCB (PCB2).


6. Replace the Primary Grid High Voltage Connector (FM4-1006).



E066-0001 -05 Title Pre-transfer Charging Shutter HP open error


Detection description


The Pre-transfer Charging Shutter Sensor (PS95) detects


that the shutter is opened although it is moved to the close position.


Remedy
1
. Check the position of the Pre-transfer Charging Shutter.



1-A
. In the case that the Pre-transfer Charging Shutter fails to operate (stopped at HP at front side)


Check the connection of the Pre-transfer Charging Wire Cleaning Motor (M7).


Sensor side: J3108, J3089 (relay), PCB side: J3088 (relay), J114 (Main Driver PCB (PCB2))



1-B
. In the case that the Pre-transfer Charging Shutter is stopped at rear side (close operation position)



1-B-1
. Check that the Primary Fan Duct is closed. Close the Primary Fan Duct.



1-B-2
. Check movement of the pin to push the Pretransfer


Charging Shutter Sensor (PS95). Replace the Pin.



1-B-3
. Check movement of the flag on the Pre-transfer


Charging Shutter Sensor (PS95). Replace the flag/spring.



1-B-4
. Check the connection of the Pre-transfer Charging Shutter Sensor (PS95).


Sensor side: J2114, J3215 (relay), J3067 (relay) PCB side: J3066 (relay), J130 (Main Driver PCB (PCB2))



1-C
. In the case that the Pre-transfer Charging Shutter is stopped along the way



1-C-1
. Check abrasion of the Slider Pin. Replace the Slider Pin.



1-C-2
. Replace the Pre-transfer Charging Assembly.


2. Replace the DC Controller PCB (PCB1).



E066-0002 -05 Title Pre-transfer Charging Shutter HP close error


Detection description


The Pre-transfer Charging Shutter Sensor (PS95) detects that


the shutter is closed although it is moved to the open position.


Remedy
1.
Check the position of the Pre-transfer Charging Shutter.



1-A.
In the case that the Pre-transfer Charging Shutter fails to operate (stopped at HP at front side)


Check the connection of the Pre-transfer Charging Wire Cleaning Motor (M7).


Sensor side: J3108, J3089 (relay), PCB side: J3088 (relay), J114 (Main Driver PCB (PCB2))



1-B.
In the case that the Pre-transfer Charging Shutter is stopped at rear side (close operation position)



1-B-1.
Check that the Primary Fan Duct is closed. Close the Primary Fan Duct.



1-B-2.
Check movement of the pin to push the Pretransfer


Charging Shutter Sensor (PS95). Replace the Pin.



1-B-3.
Check movement of the flag on the Pre-transfer


Charging Shutter Sensor (PS95). Replace the flag/spring.



1-B-4.
Check the connection of the Pre-transfer Charging Shutter Sensor (PS95).


Sensor side: J2114, J3215 (relay), J3067 (relay) PCB side: J3066 (relay), J130 (Main Driver PCB (PCB2))



1-C.
In the case that the Pre-transfer Charging Shutter is stopped along the way



1-C-1.
Check abrasion of the Slider Pin. Replace the Slider Pin.



1-C-2.
Replace the Pre-transfer Charging Assembly.


2. Replace the DC Controller PCB (PCB1).



E067-0001 -05 Title Developing high voltage output leak error


Detection description


The leak detection signal was detected 5 times in a row for every 20 msec.


Remedy 1. Check the connection between the Main Driver PCB (PCB2) and the High Voltage Unit.


Main Driver side: J112, High Voltage Unit side: J3098


2. Check the connection between the Relay PCB (PCB5) and the High Voltage Unit.


Relay side: J519, High Voltage Unit side: J3099


3. Replace the Developing Assembly.


4. Check the connection point of the Developing Assembly. If it is soiled, clean it.


5. Check the connection inside of the High Voltage Unit.


Check the connection of the High Voltage Unit Relay (J3097)


and the Developing High Voltage PCB (J3511).


High Voltage Unit Relay (J3099) and Pre-transfer Charging


PCB (J3545, J3500, J3510)


6. Replace the Main Driver PCB (PCB2).



E068-0001 -05 Title Pre-transfer charging high voltage output leak error


Detection description


The leak detection signal was detected 5 times in a row for every 20 msec.


Remedy 1. Check the connection between the Main Driver PCB (PCB2)


and the High Voltage Unit. Main Driver side: J112, High Voltage Unit side: J3098


2. Check the connection between the Relay PCB (PCB5) and the High Voltage Unit.


Relay side: J519, High Voltage Unit side: J3099


3. Replace the Pre-transfer Charging Assembly.


4. Check the connection inside of the High Voltage Unit.


Check the connection of the High Voltage Unit Relay (J3098)


and the Transfer High Voltage PCB (J3544).


Check the connection of the High Voltage Unit Relay (J3099)


and the Pre-transfer Charging PCB (J3545, J3500)


5. Replace the Main Driver PCB (PCB2).


6. Replace the Pre-transfer High Voltage Connector (FM4-1007).


7. Replace the Pre-transfer Transformer (Post ChargingTrance) of the High Voltage Unit.



E069-0001 -05 Title Transfer high voltage output leak error


Detection description


The leak detection signal was detected 5 times in a row for every 20 msec.


Remedy 1. Check the connection between the Duplex Driver PCB (PCB4) and the High Voltage Unit.


Check the connection at Duplex Driver side (J343) and theTransfer High Voltage side (J3066).


Check the connection at Duplex Driver side (J311) and the


Transfer High Voltage side (J3061). (In addition, check that 24 V is output.)


2. Check the connection of the Transfer High Voltage PCB (J3306).


3. Replace the ETB Unit.


4. Replace the Duplex Driver PCB (PCB4).



Thousands of Parts and Free Shipping



 

No comments: