Thursday, May 1, 2014

Errorcode E060-E069 For Canon ImageRunner Advance 6055 6065 6075

Thousands of Parts and Free Shipping


 

E060-0001 -05 Title Primary Charging Shutter HP open error
Remedy
1. Check the position of the Primary Charging Shutter and the Cleaning Pad.1-A. In the case that the Primary Charging Shutter and the
Cleaning Pad fail to operate (stopped at HP at front side)
1-A-1. Check the connection of the Primary Charging Wire Cleaning Motor (M6).
Motor side: J3017, J3060 (iR-ADV 8xxx)/J3160 (iRADV
6xxx) (relay), PCB side: J3177 (relay), J107 (Main Driver PCB (PCB2))
1-A-2. Replace the Primary Charging Wire Cleaning Motor (M6).


1-B. In the case that the Primary Charging Shutter and the

Cleaning Pad are stopped at rear side (close operation position)
1-B-1. Check the connection of the Primary Charging Shutter Sensor (PS94).
Sensor side: J2029, J3089 (relay), PCB side: J3088 (relay), J114 (Main Driver PCB (PCB2))
1-B-2. Replace the Primary Charging Shutter Sensor (PS94).
1-C. In the case that the Primary Charging Shutter and the Cleaning Pad are stopped along the way
1-C-1. Check the loosening of screw on the Slider Pin and
abrasion of the pin. Tighten the screw or replace the Slider Pin.
1-C-2. Replace the Primary Charging Assembly.
1-D. In the case that the Primary Charging Shutter stops at front side and the Cleaning Pad moves to rear side
1-D-1. Check if the Shutter Mounting Plate is deformed. If so, replace the Shutter Unit.
1-D-2. Check the loosening of screw on the Slider Pin and abrasion of the pin. Tighten the screw or replace the Slider Pin.
1-D-3. Replace the Primary Charging Assembly. 2. Replace the Main Driver PCB (PCB2).
3. Replace the DC Controller PCB (PCB1).
Description The Primary Charging Shutter Sensor (PS94) detects that the
shutter is opened although it is moved to the close position.
E060-0002 -05 Title Primary Charging Shutter HP close errorRemedy
1. Check the position of the Primary Charging Shutter and the Cleaning Pad.1-A. In the case that the Primary Charging Shutter and the
Cleaning Pad fail to operate (stopped at HP at front side)
1-A-1. Check the connection of the Primary Charging Wire
Cleaning Motor (M6). Motor side: J3017, J3060 (iR-ADV 8xxx)/J3160 (iRADV6xxx) (relay), PCB side: J3177 (relay), J107 (Main Driver PCB (PCB2))
1-A-2. Replace the Primary Charging Wire Cleaning Motor (M6).
1-B. In the case that the Primary Charging Shutter and the
Cleaning Pad are stopped at rear side (close operation position)
1-B-1. Check the connection of the Primary Charging Shutter Sensor (PS94).
Sensor side: J2029, J3089 (relay), PCB side: J3088 (relay), J114 (Main Driver PCB (PCB2))
1-B-2. Replace the Primary Charging Shutter Sensor (PS94).
1-C. In the case that the Primary Charging Shutter and the Cleaning Pad are stopped along the way
1-C-1. Check the loosening of screw on the Slider Pin and abrasion of the pin. Tighten the screw or replace the Slider Pin.
1-C-2. Replace the Primary Charging Assembly.
2. Replace the Main Driver PCB (PCB2).
3. Replace the DC Controller PCB (PCB1).
Description The Primary Charging Shutter Sensor (PS94) detects that the
shutter is closed although it is moved to the open position.
E061-0001 -05 Title Potential control error (VL)Remedy
1. Check the connection of the Pre-exposure LED (connector connection, open circuit, the caught cable).
2. Check the installation of the Primary Charging Assembly 
(connector connection, open circuit, the caught cable).
3. Check the fixation state of the Drum and the Drum Shaft.
(Check if the drum fixation cylinder is properly installed.)
4. Check if the Dustproof Glass is soiled. If necessary, clean it.
5. Check the installation of the Laser Scanner Unit (connector connection, open circuit, the caught cable).
6. Check the installation of the Primary Charging High Voltage
PCB (PCB11), and its connection (connector connection, open circuit, the caught cable).
7. Check the installation of the Potential Sensor (connector connection, open circuit, the caught cable).
8. Check the installation of the Drum Motor (M1), and its
connection (connector connection, open circuit, the caught cable).
9. Replace the parts.
Primary Charging Assembly
• Laser Scanner Unit
• Potential Sensor
• Primary Charging High Voltage PCB (PCB11)
• Drum Motor (M1)
• Main Driver PCB (PCB2)
• DC Controller PCB (PCB1)
Description The measured value in the dark area (VL) differs +/-30V or
higher than the target potential at potential control.
NOTE:
If the difference is somewhere between +/-10V and less than 30V, alarm is indicated.
E061-0101 -05 Title Potential control error (VD)
Remedy
1. Check the connection of the Pre-exposure LED (connectorconnection, open circuit, the caught cable).
2. If the current value of the Primary Charging Roller (COPIER
> DISPLAY > DPOT > PRIM-C) is 1550 micro A or higher,execute 2-1 to 3.
2-1. Increase the grid voltage of the Primary Charging 
    Assembly by 100V (COPIER > ADJUST > HV-PRI > PRI-GRID).
2-2. Execute the potential control (COPIER > FUNCTION > DPC > DPC).
2-3. Turn OFF and then ON the power.
3. Check the installation of the Primary Charging Assembly
(connector connection, open circuit, the caught cable).
4. Check the installation of the Primary Charging High Voltage
PCB (PCB11), and its connection (connector connection, open circuit, the caught cable).
5. Check the installation of the Drum Motor (M1), and its
connection (connector connection, open circuit, the caught cable).
6. Replace the parts.
Primary Charging Assembly
• Primary Charging High Voltage PCB
• Drum Motor (M1)
• Main Driver PCB (PCB2)
• DC Controller PCB (PCB1)
Description Potential in the dark area did not fall within the range (target
value +/-10V) although retry was executed 8 times at VD potential control.
E064 -00FF -05 Title High voltage setting error
Remedy
1. Turn OFF and then ON the main power.2. Replace the DCON PCB.
Description With the state in which the developing AC is output, 600V or
higher developing DC output was detected. (Basically, this error is not detected. However, to detect that
the image formation-related backup data is corrupted or to
protect the hardware in case of 600V or higher developing DC output, this is to be an error.)
E065 -0001 -05 Title Primary charging/grid high voltage output leak errorRemedy 1. Check the connection between the Main Driver PCB (PCB2) and the High Voltage Unit. Main Driver side: J111, High Voltage Unit side: J3097
2. Check the connection between the Relay PCB (PCB5) and
the High Voltage Unit. Relay side: J519, High Voltage Unit side: J3099
3. Replace the Primary Charging Assembly.
4. Check the connection inside of the High Voltage Unit. High Voltage Unit Relay (J3097) and Primary Charging High Voltage PCB (PCB11) (J3501) High Voltage Unit relay (J3099) and Pre-transfer Charging PCB (PCB26) (J3545, J3500)
5. Replace the Main Driver PCB (PCB2).
6. Replace the Primary Grid High Voltage Connector (FM4-1006).
Description The leak detection signal was detected 5 times in a row for every 20 msec.
E066-0001 -05 Title Pre-transfer Charging Shutter HP open errorRemedy 1. Check the position of the Pre-transfer Charging Shutter.
1-A. In the case that the Pre-transfer Charging Shutter fails to operate (stopped at HP at front side)
Check the connection of the Pre-transfer Charging WireCleaning Motor (M7).
Sensor side: J3108, J3089 (relay), PCB side: J3088 (relay), J114 (Main Driver PCB (PCB2))
1-B. In the case that the Pre-transfer Charging Shutter is stopped at rear side (close operation position)
1-B-1. Check that the Primary Fan Duct is closed. Close the Primary Fan Duct.
1-B-2. Check movement of the pin to push the Pre-transfer Charging Shutter Sensor (PS95). Replace the Pin.
1-B-3. Check movement of the flag on the Pre-transfer Charging Shutter Sensor (PS95). Replace the flag/spring.
1-B-4. Check the connection of the Pre-transfer Charging Shutter Sensor (PS95). Sensor side: J2114, J3215 (relay), J3067 (relay) PCB side: J3066 (relay), J130 (Main Driver PCB (PCB2))
1-C. In the case that the Pre-transfer Charging Shutter is stopped along the way
1-C-1. Check abrasion of the Slider Pin. Replace the Slider Pin.
1-C-2. Replace the Pre-transfer Charging Assembly.
2. Replace the DC Controller PCB (PCB1).
Description The Pre-transfer Charging Shutter Sensor (PS95) detects
that the shutter is opened although it is moved to the close position.
E066 -0002 -05 Title Pre-transfer Charging Shutter HP close error
Remedy 1. Check the position of the Pre-transfer Charging Shutter.
1-A. In the case that the Pre-transfer Charging Shutter fails to operate (stopped at HP at front side)
Check the connection of the Pre-transfer Charging Wire Cleaning Motor (M7).
Sensor side: J3108, J3089 (relay), PCB side: J3088 (relay), J114 (Main Driver PCB (PCB2))
1-B. In the case that the Pre-transfer Charging Shutter is stopped at rear side (close operation position)
1-B-1. Check that the Primary Fan Duct is closed. Close the Primary Fan Duct.
1-B-2. Check movement of the pin to push the Pre-transfer Charging Shutter Sensor (PS95). Replace the Pin.
1-B-3. Check movement of the flag on the Pre-transfer Charging Shutter Sensor (PS95). Replace the flag/ spring.
1-B-4. Check the connection of the Pre-transfer Charging Shutter Sensor (PS95).
Sensor side: J2114, J3215 (relay), J3067 (relay) PCB side: J3066 (relay), J130 (Main Driver PCB (PCB2))
1-C. In the case that the Pre-transfer Charging Shutter is stopped along the way
1-C-1. Check abrasion of the Slider Pin. Replace the Slider Pin.
1-C-2. Replace the Pre-transfer Charging Assembly.
2. Replace the DC Controller PCB (PCB1).
Description The Pre-transfer Charging Shutter Sensor (PS95) detects
that the shutter is closed although it is moved to the open position.
E067 -0001 -05 Title Developing high voltage output leak error
Remedy 1. Check the connection between the Main Driver PCB (PCB2)
and the High Voltage Unit. Main Driver side: J112, High Voltage Unit side: J3098
2. Check the connection between the Relay PCB (PCB5) and
the High Voltage Unit. Relay side: J519, High Voltage Unit side: J3099
3. Replace the Developing Assembly.
4. Check the connection point of the Developing Assembly. If it is soiled, clean it.
5. Check the connection inside of the High Voltage Unit.
 Check the connection of the High Voltage Unit Relay
(J3097) and the Developing High Voltage PCB (J3511).
High Voltage Unit Relay (J3099) and Pre-transfer Charging PCB (J3545, J3500, J3510)
6. Replace the Main Driver PCB (PCB2).
Description The leak detection signal was detected 5 times in a row for every 20 msec.
E068 -0001 -05 Title Pre-transfer charging high voltage output leak error
Remedy
1. Check the connection between the Main Driver PCB (PCB2)and the High Voltage Unit. Main Driver side: J112, High Voltage Unit side: J3098
2. Check the connection between the Relay PCB (PCB5) and
the High Voltage Unit. Relay side: J519, High Voltage Unit side: J3099
3. Replace the Pre-transfer Charging Assembly.
4. Check the connection inside of the High Voltage Unit.
   Check the connection of the High Voltage Unit Relay
   (J3098) and the Transfer High Voltage PCB (J3544).
    Check the connection of the High Voltage Unit Relay
    (J3099) and the Pre-transfer Charging PCB (J3545, J3500)
5. Replace the Main Driver PCB (PCB2).
6. Replace the Pre-transfer High Voltage Connector (FM4- 1007).
7. Replace the Pre-transfer Transformer (Post Charging Trance) of the High Voltage Unit.
Description The leak detection signal was detected 5 times in a row for every 20 msec.
E069 -0001 -05 Title Transfer high voltage output leak errorRemedy 1. Check the connection between the Duplex Driver PCB (PCB4) and the High Voltage Unit.
Check the connection at Duplex Driver side (J343) and the Transfer High Voltage side (J3066).
Check the connection at Duplex Driver side (J311) and the Transfer High Voltage side (J3061). (In addition, check that 24V is output.)
2. Check the connection of the Transfer High Voltage PCB (J3306).
3. Replace the ETB Unit.
4. Replace the Duplex Driver PCB (PCB4).
Description The leak detection signal was detected 5 times in a row for every 20 msec.

Thousands of Parts and Free Shipping


 