Tuesday, May 6, 2014

ErrorCode E804 To E880 for Canon ImageRunner Advance 6255 6265 6275

Thousands of Parts and Free Shipping




 

E804-0000 -05 Title Power Supply Cooling Fan 1/2 error
Detection description
The Fan stop signal is detected for 5 seconds or longer and retry is failed 4 times in a row although the Power Supply Cooling Fan 1 (FM14)/Power Supply Cooling Fan 2 (FM15) is
turned ON. The error detection signal cable is shared with the Fans, and it is not detected with which Fan the error occurs.
Remedy 1. Check the connection of the Connector. 2. Replace the Power Supply Cooling Fan 1 (FM14)/Power Supply Cooling Fan 2 (FM15).
E804-0001 -05 Title Fixing Power Supply Cooling Fan error
Detection description The Fan stop signal is detected for 1.5 seconds or longer and retry is failed 4 times in a row although the Fixing Power Supply Cooling Fan (FM7) is turned ON.
Remedy 1. Check the connection of the Connector.
2. Replace the Fixing Power Supply Cooling Fan (FM7).
E806-0000 -05 Title Making Image Exhaust Fan error
Detection description The Fan stop signal is detected for 5 seconds or longer and
retry is failed 4 times in a row although the Making Image Exhaust Fan (FM3) is turned ON.
Remedy 1. Check the connection of the Connector.
2. Replace the Making Image Exhaust Fan (FM3).
E808-0001 -05 Title Fixing Power Supply error
Detection description Detected 145 V (100 V/120 V model)/290 V (230 V model) or
higher inlet voltage at power-on.
Remedy 1. Check the outlet voltage. -> Connect to the correct outlet.
2. Check the connection between the Main Driver PCB (PCB2) and the Fixing Power Supply PCB (PCB10).
3. Replace the Fixing Power Supply PCB (PCB10).
4. Replace the Main Driver PCB (PCB2).
E808-0002 -05 Title Fixing Power Supply error
Detection description Detected 75 V (100 V/120 V model)/150 V (230 V model) or
higher inlet voltage at power-on.
Remedy 1. Check the outlet voltage. -> Connect to the correct outlet.
2. Check the connection between the Main Driver PCB (PCB2) and the Fixing Power Supply PCB (PCB10).
3. Replace the Fixing Power Supply PCB (PCB10).
4. Replace the Main Driver PCB (PCB2).
E808-0003 -05 Title Fixing Power Supply error
Detection description Inlet current is 1 A or lower for 1 second or longer although the
maximum voltage is output.
Remedy 1. Check the clogging of the Fixing Power Supply Cooling Fan (FM7).
2. Check the clogging of the Louver on right side of the host machine (Multi-purpose Tray side).
3. Check the connection of the Fixing Power Supply PCB (PCB10) Output Connector.
4. Replace the Fixing Power Supply PCB (PCB10).
E808-0004 -05 Title Fixing Power Supply error
Detection description Detected OFF with 12 V of the Main Driver PCB (PCB2) output.
Remedy Replace the Main Driver PCB (PCB2).
E808-0005 -05 Title 12 V OFF detection when relay is turned ON
Detection description Detected OFF with 12 V of the Fixing Power Supply output
after IH relay is turned ON.
Remedy 1. Check the conduction of the Fixing Thermal Switch 1/2 (TP1/2).
2. Check the drawer between the Fixing Assembly and the host machine.
3. Check the connection between the Main Driver PCB (PCB2) and the Fixing Power Supply PCB (PCB10).
4. Replace the Fixing Power Supply Unit.
5. Replace the Main Driver PCB (PCB2).
E808-0006 -05 Title ASIC error
Detection description ASIC error.
Remedy Replace the DC Controller PCB (PCB1).
E808-0007 -05 Title Fixing Power Supply error
Detection description The detected power voltage differs from the voltage of the port
in the IH Power Supply.
Remedy 1. Check the connection between the Main Driver PCB (PCB2)
and the Fixing Power Supply PCB (PCB10).
2. Replace the Fixing Power Supply PCB with the one for the correct location (voltage).
3. Replace the DC Controller PCB (PCB1).
E808-0008 -05 Title Fixing Power Supply error
Detection description Current fluctuation error.
Remedy 1. Check the connection between the Main Driver PCB (PCB2)
and the Fixing Power Supply PCB (PCB10).
2. Check the connection between the Fixing Power Supply PCB (PCB10) and the Heater Unit.
3. Replace the Fixing Roller and Heater Unit.
4. Replace the Fixing Power Supply PCB (PCB10).
5. Replace the Main Driver PCB (PCB2).
E808-0009 -05 Title Fixing Power Supply error
Detection description Unable to clear the error flag at power-on.
Remedy Replace the DC Controller PCB (PCB1).
E820-0000 -05 Title Developer Lower Cooling Fan error
Detection description The Fan stop signal is detected for 5 seconds or longer and
retry is failed 4 times in a row although the Developer Lower Cooling Fan (FM30) is turned ON.
Remedy 1. Check the connection of the Connector.
2. Replace the Developer Lower Cooling Fan (FM30).
E820-0001 -05 Title Developer Upper Cooling Fan error
Detection description The Fan stop signal is detected for 5 seconds or longer and
retry is failed 4 times in a row although the Developer Upper Cooling Fan (FM31) is turned ON.
Remedy 1. Check the connection of the Connector.
2. Replace the Developer Upper Cooling Fan (FM31).
E820-0002 -05 Title Duplex Driver Cooling Fan error
Detection description The Fan stop signal is detected for 5 seconds or longer and
retry is failed 4 times in a row although the Duplex Driver Cooling Fan (FM41) is turned ON.
Remedy 1. Check the connection of the Connector.
2. Replace the Duplex Driver Cooling Fan (FM41).
E824-0000 -05 Title Primary Charging Air Supply Fan error
Detection description The Fan stop signal is detected for 5 seconds or longer and
retry is failed 4 times in a row although the Primary Charging Air Supply Fan (FM2) is turned ON.
Remedy 1. Check the connection of the Connector.
2. Replace the Primary Charging Air Supply Fan (FM2).
E840-0001 -05 Title Fixing Shutter Motor error
Detection description The Fixing Shutter HP Sensor (PS53) failed the detection at
the Fixing Shutter operation.
Remedy 1. Check the operation of the Fixing Shutter Gear (overload, etc.).
2. Check the operation of the Fixing Shutter Motor (M15) at the initialization operation of the Fixing Shutter.
3. Check the detection of the Fixing Shutter HP Sensor (PS53)
(if the Sensor operates normally).
4. Check the drawer of the Fixing Assembly and the host machine.
5. Replace the Fixing Upper Unit and the Fixing Drawer
Harness Unit.
6. Replace the Main Driver PCB (PCB2) (check the fuse (FU11)).
E880-0001 -00 Title Controller Fan error
Detection description Error in the Main Controller Cooling Fan (FM4) is detected.
Remedy Connector disconnection, failure of Fan.
E880-0005 -00 Title Controller Fan error
Detection description Error in the HDD Cooling Fan (FM) is detected.
Remedy Connector disconnection, failure of Fan.


Thousands of Parts and Free Shipping



 

No comments:

Post a Comment