Thursday, May 1, 2014

Errorcodes E000-E005 For Canon ImageRunner Advance 6055 6065 6075



E000-0001 -05 Title Fixing Assembly low temperature error
Remedy
1. Check the connection of the Fixing Assembly. (Connection
   error of the Drawer, connector disconnection, open circuit)  -> Replace the Heater Assembly.
2. Check the connection between the Main Driver PCB (PCB2) and the Fixing Power Supply PCB (PCB10)          (connector disconnection, open circuit, the caught cable).
3. Replace the Fixing Power Supply PCB (PCB10).
4. Replace the Main Driver PCB (PCB2).
5. Replace the DC Controller PCB (PCB1).
Description
Temperature of the Fixing Main Thermistor (THM1) does
not reach 70 degC although 20 seconds have passed after
starting the Fixing Roller temperature control.
E000-0002 -05 Title Fixing Assembly low temperature error
Remedy
1. Check the connection of the Fixing Assembly. (Connection 
  error of the Drawer, connector disconnection, open circuit)
   -> Replace the Heater Assembly.
2. Check the connection between the Main Driver PCB (PCB2)
    and the Fixing Power Supply PCB (PCB10) (connector
    disconnection, open circuit, the caught cable).
3. Replace the Fixing Power Supply PCB (PCB10).
4. Replace the Main Driver PCB (PCB2). 5. Replace the DC Controller PCB (PCB1).
Description Temperature of the Fixing Main Thermistor (THM1) does
not reach 10 degC although 20 seconds have passed after starting the Fixing Roller temperature control.
E000-0010 -05 Title Fixing Assembly low temperature error
Remedy Clear the error.
Description Turning OFF and then ON the power without clearing the error.
E001-0002 -05 Title Fixing Assembly high temperature error (software detection)
Remedy
1. Check if the cable of the Thermistor is caught. -> Replacethe Thermistors. -> Replace the Fixing Upper Unit.
2. IH control error. -> Replace the Fixing Power Supply PCB
(PCB10), the DC Controller PCB (PCB1), or the Main Driver PCB (PCB2).
Descriptionthe Fixing Main Thermistor (THM1) detects 230 degC or higher.
The Fixing Sub Thermistor 1 (THM2)/Fixing Sub Thermistor
2 the Fixing Main Thermistor (THM3) detects 230 degC or higher for 2 consecutive seconds.
E001-0003 -05 Title Fixing Assembly high temperature error (hardware detection)
Remedy
1. Check if the cable of the Thermistor is caught. -> Replace
   the Thermistors. -> Replace the Fixing Upper Unit.
2. Replace the Main Driver PCB (PCB2).
3. Replace the DC Controller PCB (PCB1).
Descriptionthe Fixing Main Thermistor (THM1) detects hardware overheating.
The Fixing Sub Thermistor 1 (THM2)/Fixing Sub Thermistor
2 the Fixing Main Thermistor (THM3) detects hardware overheating.
E001-0004 -05 Title Fixing Assembly high temperature error (hardware detection)
Remedy
1. Check if the cable of the Thermistor is caught or is open
circuit. -> Replace the Thermistors. -> Replace the Fixing Upper Unit.
2. Replace the Main Driver PCB (PCB2).3. Replace the DC Controller PCB (PCB1).
4. Check if the Fixing Shutter operates. -> Replace the Fixing Assembly.
Description Abnormal temperature difference among the Thermistors was detected.
E001-0010 -05 Title Fixing Assembly high temperature error
Remedy Clear the error.
Description Turning OFF and then ON the power without clearing the error.
E002-0001 -05 Title Fixing Assembly temperature rise error
.Remedy
1. Check the connection of the Fixing Main Thermistor (THM1). -> Replace the Fixing Main Thermistor Unit.
2. Check the installation of the Fixing Main Thermistor. ->Replace the Fixing Upper Unit.
3. Replace the Fixing Power Supply PCB (PCB10).
4. Replace the Main Driver PCB (PCB2).
5. Replace the DC Controller PCB (PCB1).
6. Replace the Relay PCB (PCB5).
Description • Temperature of the Fixing Main Thermistor (THM1) does not reach 100 degC although 12 seconds have passed since it reached above 70 degC after starting the Fixing Roller temperature control.

• Temperature of the Fixing Main Thermistor does not reach 130 degC although 12 seconds have passed since it
reached above 100 degC after starting the Fixing Roller temperature control.
• Temperature of the Fixing Main Thermistor does not reach 150 degC although 20 seconds have passed since it
reached above 130 degC after starting the Fixing Roller temperature conrtol.
E002-0010 -05 Title Fixing Assembly temperature rise error
Remedy Clear the error.
Description Turning OFF and then ON the power without clearing the error.
E003-0000 -05 Title Fixing Assembly temperature decrease error
Remedy
1. Check the connection of the Fixing Main Thermistor(THM1). -> Replace the Fixing Main Thermistor Unit.
2. Check the installation of the Fixing Main Thermistor . ->Replace the Fixing Upper Unit.
3. Replace the Fixing Power Supply PCB (PCB10). 4. Replace the Main Driver PCB (PCB2).
5. Replace the DC Controller PCB (PCB1). 6. Replace the Relay PCB (PCB5).
Description the Fixing Main Thermistor (THM1) detects 70 degC or lower for 2 seconds or longer although the temperature reached above 100 degC after starting the Fixing Roller temperature control.
E003-0010 -05 Title Fixing Assembly temperature decrease error
Remedy Clear the error.
Description Turning OFF and then ON the power without clearing the
E004-0010 -05 Title Fixing Power Supply error
Remedy Clear the error.
Description Turning OFF and then ON the power without clearing the error.
E004-0205 -05 Title Fixing Power Supply error
Remedy
1. Check the harness of the Fixing Main Thermistor (THM1) in the Fixing Assembly.
2. Check the connection of the harness of the FixingAssembly on the host machine side.
3. Replace the Main Driver PCB (PCB2).
Description Detect that the Fixing Main Thermistor Unit is not connected.
E005-0000 -05 Title Fixing Cleaning Web absent error
Remedy
1. Replace the Fixing Cleaning Web.
2. Replace the Fixing Cleaning Web Level Sensor (PS45).
3. Replace the DC Controller PCB (PCB1).
After executing the measures, clear the Fixing Cleaning
Web counter (COPIER > COUNTER > MISC > FIXWEB).
Description After noticing the Fixing Cleaning Web absent, the web was pulled out 2000 times.
E005-0001 -05 Title Error in Fixing Cleaning Web Drive Solenoid connection
Remedy
1. Check the connection of the Connector.
2. Replace the Fixing Cleaning Web Drive Solenoid (SL9).
Description Connection of the Fixing Cleaning Web Drive Solenoid (SL9) is not detected when the power is turned ON.
E005-0010 -05 Title Fixing Cleaning Web error
Remedy Clear the error.
Description Turning OFF and then ON the power without clearing the error.

Thousands of Parts and Free Shipping




 