Sunday, May 4, 2014

Errorcode E301 To E355 for Canon ImageRunner Advance 6255 6265 6275

Thousands of Parts and Free Shipping


 
E301-0001 -04 Title Paper front light intensity NG
Detection description
Light intensity is below the reference level at paper front shading.
Remedy Failure of the Scanner Unit (Reader).
E301-0101 -04 Title Paper back light intensity NG
Detection description
Light intensity is below the reference level at paper back shading.
Remedy Failure of the Scanner Unit (DADF).
E302-0001 -04 Title Error in paper front shading
Detection description Error in shading RAM access, or the shading value is either
below or higher than the reference level.
Remedy 1. Connector disconnection/open circuit of the Scanner Unit (Reader).
2. Connector disconnection/open circuit of the Reader Controller PCB (PCB1).
3. Failure of the Scanner Unit (Reader).
4. Failure of the Reader Controller PCB (PCB1).
E302-0101 -04 Title Error in paper back shading
Detection description Error in shading RAM access, or the shading value is either
below or higher than the reference level.
Remedy 1. Connector disconnection/open circuit of the Scanner Unit (DADF).
2. Connector disconnection/open circuit of the Reader Controller PCB (PCB1).
3. Operation error of the Glass Shift Motor (M9).
4. Failure of the Scanner Unit (DADF).
5. Failure of the Reader Controller PCB (PCB1).
E315-0007 -00 Title Codec error
Detection description JBIG encode error.
Remedy Replacement of the Main Controller PCB.
E315-000d -00 Title Codec error
Detection description JBIG decode error.
Remedy 1. Replacement of SDRAM. 2. Replacement of HDD.
3. Replacement of the Main Controller PCB.
E315-000e -00 Title Codec error
Detection description Software decode error.
Remedy 1. Replacement of SDRAM.
2. Replacement of HDD.
3. Replacement of the Main Controller PCB.

E315-0025 -00 Title Codec error
Detection description ROTU hardware error.
Remedy Replacement of the Main Controller PCB.
E315-0027 -00 Title Codec error
Detection description ROTU timeout error.
Remedy Replacement of the Main Controller PCB.
E315-0033 -00 Title MemFill hardware error
Detection description MemFill hardware error.
Remedy Replacement of the Main Controller PCB.
E315-0035 -00 Title Codec error
Detection description MemFill timeout error.
Remedy Replacement of the Main Controller PCB.
E315-0100 -00 Title Codec error
Detection description PrcOverRun error.
Remedy Replacement of the Main Controller PCB.
E315-0500 -00 Title Codec error
Detection description
Interruption does not occur although 2 minutes have passed
after starting the operation.
Remedy jcdImage device.
E315-0501 -00 Title Codec error
Detection description
Abnormal interruption is detected after starting the operation.
Remedy jcdImage device.
E315-0510 -00 Title Codec error
Detection description
Interruption does not occur although 2 minutes have passed after starting the operation.
Remedy jcdImage device.
E315-0511 -00 Title Codec error
Detection description Abnormal interruption is detected after starting the operation.
Remedy jcdImage device.
E315-0520 -00 Title Codec error
Detection description Interruption does not occur although 2 minutes have passed
after starting the operation.
Remedy jcdImage device.
E315-0521 -00 Title Codec error
Detection description Abnormal interruption is detected after starting the operation.
Remedy jcdImage device.

E315-0530 -00 Title Codec error
Detection description Interruption does not occur although 2 minutes have passed
after starting the operation.
Remedy jcdImage device.
E315 0531 -00 Title Codec error
Detection description Abnormal interruption is detected after starting the operation.
Remedy jcdImage device.
E315-0540 -00 Title JPEG decode error
Detection descriptionThis error occurs when images buffered in the HDD or
memory were corrupted when performing image processing. JPEG decode is used when handling color (or gray) images.Therefore, the error does not occur for normal copy or PDL
print. But it may occur with SEND.
Remedy 1. Turn OFF and then ON the powerIf it is not recovered or it occurs frequently, perform the following measures.
2. Format the HDD. If it is not recovered, replace the HDD.
3. Replace the memory on the Main Controller 2 (DDR2-SDRAM).
4. Replace the Main Controller PCB 2.
E315-0541 -00 Title Codec error
Detection description Abnormal interruption is detected after starting the operation.
Remedy jcdImage device.
E315 0550 -00 Title Codec error
Detection description Interruption does not occur although 2 minutes have passed
after starting the operation.
Remedy jcdImage device.
E315-0551 -00 Title Codec error
Detection description Abnormal interruption is detected after starting the operation.
Remedy jcdImage device.
E315-0560 -00 Title Codec error
Detection description Interruption does not occur although 2 minutes have passed
after starting the operation.
Remedy jcdImage device.
E315-0561 -00 Title Codec error
Detection descriptionAbnormal interruption is detected after starting the operation.
Remedy jcdImage device.
E350-0000 -00 Title System error
Detection description---
Remedy Contact to the sales companies.

E350-0001 -00 Title System error
Detection description---
Remedy Contact to the sales companies.
E350-0002 -00 Title System error
Detection description ---
Remedy Contact to the sales companies.
E350-0003 -00 Title System error
Detection description---
Remedy Contact to the sales companies.
E350-3000 -00 Title System error
Detection description---
Remedy Contact to the sales companies.
E351-0000 -00 Title Main Controller PCB 2 communication error
Detection description Main Controller PCB 2 communication error.
Remedy 1. Disconnect and then connect the connector of the Main Controller PCB 2.
2. Replace the Main Controller PCB 2.
E354-0001 -00 Title System error
Detection description---
Remedy Contact to the sales companies.
E354-0002 -00 Title System error
Detection description---
Remedy Contact to the sales companies.
E355-0001 -00 Title System error
Detection description ---
Remedy Contact to the sales companies.
E355-0003 -00 Title System error
Detection description---
Remedy Contact to the sales companies.
E355-0004 -00 Title System error
Detection description---
Remedy Contact to the sales companies.


Thousands of Parts and Free Shipping



 

No comments:

Post a Comment