E730-1001 -00 Title PDL software error
Detection description Initialization error.
Remedy 1. PDL reset processing. 2. Turn OFF and then ON the power.
E730-100A -00 Title PDL software error
Detection description Systematic fatal error, such as initialization failure, occurs.
Remedy 1. PDL re set processing. 2. Turn OFF and then ON the power.
E730-9004 -00 Title Third party PDL communication error
Detection description Communication error with the print server.
Remedy 1. Turn OFF and then ON the power. 2. Check the cable connection.
3. Replace the Open I/F PCB, F Link PCB (Main/Sub).
4. Replace the Main Controller PCB.
E730-9005 -00 Title Third party PDL communication error
Detection description Error in video cable connection with the print server.
Remedy 1. Turn OFF and then ON the power. 2. Check the cable connection.
3. Replace the Open I/F PCB, F Link PCB (Main/Sub).
4. Replace the Main Controller PCB.
E730-A006 -00 Title PDL communication error
Detection description No reply from PDL. Due to failure of Subbootable, or no
existence, there is no reply from PDL.
Remedy 1. PDL reset processing. 2. Turn OFF and then ON the power.
3. Check the connection of the Main Controller PCB. 4. Reinstall the firmware.
5. Replace the Main Controller PCB.
E730-A007 -00 Title Mismatched PDL version
Detection description Version of the host machine control software and version of
PDL control software are different.
Remedy 1. PDL reset processing. 2. Turn OFF and then ON the power.
3. System All Format and installation.
E730-B013 -00 Title PDL embedded font error
Detection description Font data is corrupted.
Remedy 1. Turn OFF and then ON the power. 2. Reinstall the system.
3. System All Format and installation.
E732-0000 -00 Title Reader communication error
Detection description Negotiation failure.
Remedy 1. Check the connection of the Connector with the Reader.
2. Check the power of the Reader (check if the initialization operation is executed at startup).
3. Replace the Reader Controller PCB and the Main Controller PCB.
E732-0001 -00 Title Reader communication error
Detection description Communication error.
Remedy 1. Check the connection of the Connector with the Reader.
2. Check the power of the Reader (check if the initialization operation is executed at startup).
3. Replace the Reader Controller PCB and the Main Controller PCB.
E732-0010 -00 Title Reader communication error
Detection description Unable to detect Vsync from the Reader Controller although 2
minutes have passed after the completion of register setting of the Main Controller.
Remedy 1. Check the connection of the Connector with the Reader.
2. Check the power of the Reader (check if the initialization operation is executed at startup).
3. Replace the Reader Controller PCB and the Main Controller PCB
E732-0023 -00 Title Scanner communication error
Detection descriptionSPRDY-S signal cannot be detected (Hardware failure of DDI-S)
 1. Check of connector of scanner connection
2. Check of scanner power (check whether initialization
operation is executed or not at start-up)
3. Replacement of RCON, scanner board or main controller PCB
E732-8888 -00 Title Error in the reader type
Detection description When a scanner for the different model is detected during the
communication with the reader.
Remedy Replace to the proper reader.
E732-9999 -00 Title Detection of Reader
Detection description
The Reader is detected for the first time with the printer model.
(On the user screen, only the message “Turn OFF and then
ON the power again”, instead of an error code, is displayed.
It is recorded as an error log in Service Mode> COPIER>DISPLAY> ERR.)
Remedy ---
E733-0000 -00 Title Communication error between the Main Controller PCB 1 and
the DC Controller PCB
Detection description
Unable to make communication between the Main Controller PCB 1 and the DC Controller PCB. (Communication error was detected at startup.)
Remedy 1. Check the cable connection (connector connection error/
open circuit).
• DC Controller PCB: J441, J442, Main Controller PCB 2:J21, J22
• Main Controller PCB 2: J2, Main Controller PCB 1:J1019
2. Replace the DC Controller PCB/Main Controller PCB 2/MainController PCB1.
E733-0001 -00 Title Communication error between the Main Controller PCB 1 and
the DC Controller PCB
Detection description Unable to make communication between the Main Controller
PCB 1 and the DC Controller PCB. (Communication error was detected during power distribution (while the power is ON).)
Remedy 1. Turn OFF and then ON the power.
2. Check the cable connection (connector connection error/open circuit).
• DC Controller PCB: J441, J442, Main Controller PCB 2:J21, J22
• Main Controller PCB 2: J2, Main Controller PCB 1:J1019
3. Replace the DC Controller PCB/Main Controlle E733 -0002 -00 Title Communication error between the Main Controller PCB 1 and the DC Controller PCB
Detection description
Error was detected in the signal from the DC Controller PCB to
the Main Controller PCB 1. (Communication between the
DC Controller PCB and the Main Controller PCB 1 is normal.)
Remedy 1. Check the cable connection (connector connection error/
open circuit).
• DC Controller PCB: J441, J442, Main Controller PCB 2: J21, J22
• Main Controller PCB 2: J2, Main Controller PCB 1:J1019
2. Replace the DC Controller PCB/Main Controller PCB 2/Main Controller PCB1.
E733-0010 -00 Title Communication error between the Main Controller PCB 2 and
the DC Controller PCB
Detection description An image request signal is not sent from the Main Controller
PCB 2 to the DC Controller PCB. Or, a vertical synchronization signal (a signal to synchronize the write start timing in horizontal scanning direction at the time of laser exposure) is not sent from the DC Controller PCB to the Main Controller PCB 2.
Since the Main Controller PCB 1 monitors whether the foregoing communication is made normally, this error may occur when communication between the Main Controller PCB
2 and the Main Controller PCB 1 is not available.
Remedy 1. Check the cable connection (connector connection error/open circuit).
• DC Controller PCB: J441, J442, Main Controller PCB 2:J21, J22
• Main Controller PCB 2: J2, Main Controller PCB 1:J1019
2. Replace the DC Controller PCB/Main Controller PCB 2/Main
Controller PCB1.r PCB 2/Main Controller PCB1.



No comments: