(COPIER>FUNCTION>CLEAR>ERR)
0000 After power-on, the reading of the main thermistor does not increase to 70
deg C or
higher within 20 sec.
- Replace the main/shutter thermistor. - Replace the DC controller PCB.
0010 The power has been turned off and then on without resetting the error.
- Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
E001 There is an abnormal
rise in temperature. After correcting the
fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
0001 There is an error or an open circuit in the main thermistor, shutter
thermistor, or sub
thermistor. - Check the connector of
each thermistor for any fault in connection and wiring.
- Replace the thermistor in
question. - Replace the DC controller PCB.
0002 The reading of the main thermistor, shutter thermistor, or sub thermistor
is 230 deg Cor higher for 2 sec.
- Replace the thermistor in
question. - Replace the DC controller PCB.
0003 The reading is not 150 deg C or higher or 210 deg C or lower within 30
sec.
- Turn off and then back on the
power.
0010 The power has been turned off and then back on without resetting the
error.
- Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
E002 There is an abnormal
rise in temperature. After correcting the
fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
0000 The reading of the main thermistor is not 100 deg C 12 sec after it has
exceeded 70 deg C.
0001 The reading of the main thermistor is not150 deg C 15 after it has
exceeded 100 deg C.
- Check the connector of the
main/shutter thermistor for any fault in connection and wiring.
- Check the main/shutter thermistor
for mounting condition.
- Replace the main/shutter
thermistor. - Replace the fixing
heater unit.
- Replace the DC controller PCB.
0010 The power has been turned off and then back on without resetting the
error.
- Reset the error.
(COPIER>FUNCTION>CLEAR>ERR)
E003 There is an abnormal
rise in temperature. After correcting the
fault, be sure to reset the error.
(COPIER>FUNCTION>CLEAR>ERR)
0000 The reading of the main thermistor is lower than 70 deg C for 2 sec or
more after it has exceeded 100 deg C.
- Check the connector of the
main/shutter thermistor for any fault in connection and wiring.
- Check the main/shutter thermistor
for mounting condition.
- Replace the main/shutter
thermistor. - Replace the fixing heater unit.
- Replace the DC controller PCB.
0010 The power has been turned off and then
back on without resetting the error.
- Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
E004 The IH power supply is
faulty/the IH control mechanism is faulty.
After correcting the fault, be sure
to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
0101 There is a mismatch between the input voltage and the IH power supply ID.
Replace the fixing heater power
supply with one designed for the country of installation (voltage).
0102 The IH current is faulty. (current leakage) -
0103 The IH current is faulty. (no current)
0104 There is an IH over-current.
0105 The IH input voltage is too high.
0106 The IH input voltage is too low.
0201 At power-on (or, when IH is at reset), the IH control mechanism is not in
an initial state.
0202 At IH start-up, the IH control enable flag is not set within 1 sec after
the start flag is set.
0203 With IH at rest, the IH control flag is not released.
0204 The 12-V power supply (IH relay) is identified as being off.
-Check the connector for any fault
in connection.
- Replace the fixing heater power
supply. - Replace the DC controller
PCB.
0205 At IH start-up, the PWM_ON data is faulty ('0' or 'FFFF').
- Replace the DC controller PCB.
E005 There is no fixing
web/there is an error in the detection of web solenoid connection.
0000 The absence of the fixing web has
been detected for 5 sec or more.
- Replace the fixing web. - Replace
the fixing web length sensor.
- Replace the DC controller PCB.
After correcting the fault, be user
to reset the fixing web counter reading.
(COPIER>COUNTER>MISC>FIXWEB)
0001 At power-on, the connection of the web solenoid is not detected.
- Check the connector for any fault
in connection.
- Replace the solenoid.
0010 The power has been turned off and then back on without resetting the
error.
- Reset the fixing web counter. (COPIER>COUNTER>MISC>FIXWEB)
E010 There is a feed motor
error.
0000 The FG signal of the feed motor does not arrive for 2 sec or more even
when the feed
motor has been turned on.
- Check the connector for any fault
in connection.
- Replace the motor