E202 -0001 -04 Title Scanner HP error
Detection description An error occurs during the Scanner Unit (Paper Front) HP
detection operation (outward).
Remedy 1. Connector disconnection/open circuit of the Scanner HP Sensor (SR2).
2. Failure of the Scanner HP Sensor (SR2).
3. Failure of the Scanner Motor (M1).
4. Failure of the Reader Controller PCB (PCB1).
E202 -0002 -04 Title Scanner HP error
Detection description An error occurs during the Scanner Unit (Paper Front) HP
detection operation (homeward).
Remedy 1. Connector disconnection/open circuit of the Scanner HP Sensor (SR2).
2. Failure of the Scanner HP Sensor (SR2).
3. Failure of the Scanner Motor (M1).
4. Failure of the Reader Controller PCB (PCB1).
E202 -0101 -04 Title Glass HP error
Detection description An error occurs during the Glass HP detection operation (outward).
Remedy 1. Connector disconnection/open circuit of the Glass Shift HP Sensor (SR11).
2. Failure of the Glass Shift HP Sensor (SR11).
3. Failure of the Glass Shift Motor (M9).
4. Failure of the DADF Driver PCB (PCB1).
E202 -0102 -04 Title Glass HP error
Detection description An error occurs during the Glass HP detection operation (homeward).
Remedy 1. Connector disconnection/open circuit of the Glass Shift HP Sensor (SR11).
2. Failure of the Glass Shift HP Sensor (SR11).
3. Failure of the Glass Shift Motor (M9).
4. Failure of the DADF Driver PCB (PCB1).
E227 -0001 -04 Title Power supply (24 V) error
Detection description 24 V port is OFF when the power is turned ON.
Remedy 1. Connector disconnection/open circuit of the Reader Power Supply.
2. Failure of power supply.
E227 -0002 -04 Title Power supply (24 V) error
Detection description 24 V port is OFF when a job is started.
Remedy 1. Connector disconnection/open circuit of the Reader Power Supply.
2. Failure of power supply.
E227 -0003 -04 Title Power supply (24 V) error
Detection description 24 V port is OFF when a job is ended.
Remedy 1. Connector disconnection/open circuit of the Reader Power Supply.
2. Failure of power supply.
E227 -0004 -04 Title Power supply (24 V) error
Detection description 24 V port is OFF when loading.
Remedy 1. Connector disconnection/open circuit of the Reader Power Supply.
2. Failure of power supply.
E227 -0101 -04 Title Power supply (24 V) error
Detection description 24 V port is OFF when the power of DADF is turned ON.
Remedy 1. Connection error between the DADF Driver PCB (PCB1) and the Reader Controller PCB (PCB1).
2. Connector disconnection/open circuit of the Reader Power Supply.
3. Failure of power supply.
E227 -0102 -04 Title Power supply (24 V) error
Detection description 24 V port is OFF when a job is started in the DADF.
Remedy 1. Connection error between the DADF Driver PCB (PCB1) and the Reader Controller PCB (PCB1).
2. Connector disconnection/open circuit of the Reader Power Supply.
3. Failure of power supply.
E227 -0103 -04 Title Power supply (24 V) error
Detection description 24 V port is OFF when a job is ended in the DADF.
Remedy 1. Connection error between the DADF Driver PCB (PCB1) and the Reader Controller PCB (PCB1).
2. Connector disconnection/open circuit of the Reader Power Supply.
3. Failure of power supply.
E240 -0000 -05 Title Communication error between Main Controller and DC Controller
Detection description Communication error occurs between the CPU of the Main
Controller PCB and the DC Controller PCB (PCB1).
Remedy 1. Check the connection of the Main Controller PCB and the DC Controller PCB (PCB1).
Main Controller side: J712, DC Controller side: J442
2. Replace the DC Controller PCB (PCB1).
3. Replace the Main Controller PCB.
E240 -0001 -05 Title 3 minutes passed with pickup request waiting status
Detection description It was detected that 3 minutes passed with pickup request
waiting status.
Remedy 1. Check the connection of the Connector.
2. Check the connection of the Sub PCB in the Main Controller PCB 1 Box.
3. Check the connections of the DC Controller PCB and the
Main Controller PCB 1. Replace the PCB(s) if necessary.
E240 -0002 -05 Title 3 minutes passed with image output request waiting status
Detection description It was detected that 3 minutes passed with image output
request waiting status.
Remedy 1. Check the connection of the Connector.
2. Check the connection of the Sub PCB in the Main Controller PCB 1 Box.
3. Check the connections of the DC Controller PCB and the
Main Controller PCB 1. Replace the PCB(s) if necessary.
E240 -0003 -05 Title Software sequence error after the jam
Detection description A software sequence error (engine bug) was detected after the
jam.
Remedy 1. Check the connection of the Connector.
2. Check the connection of the Sub PCB in the Main Controller PCB 1 Box.
3. Check the connections of the DC Controller PCB and the
Main Controller PCB 1. Replace the PCB(s) if necessary.
E246 -0001 -00 Title System error
Detection description---
Remedy Contact to the sales companies.
E246 -0002 -00 Title System error
Detection description ---
Remedy Contact to the sales companies.
E246 -0003 -00 Title System error
Detection description---
Remedy Contact to the sales companies.
E246 -0005 -00 Title System error
Detection Description ---
Remedy Contact to the sales companies.
E247 -0001 -00 Title System error
Detection description ---
Remedy Contact to the sales companies.
E247 -0002 -00 Title System error
Detection description ---
Remedy Contact to the sales companies.
E247 -0003 -00 Title System error
Detection description ---
Remedy Contact to the sales companies.
E247 -0004 -00 Title System error
Detection description ---
Remedy Contact to the sales companies.
E248 -0000 -00 Title SRAM error
Detection description SRAM check error when the power is turned ON.
Remedy Main Controller PCB 2.
E248 -0001 -04 Title EEPROM error
Detection description  An error when EEPROM power for the Reader Controller PCB
(PCB1) is turned ON.
Remedy Failure of the Reader Controller PCB (PCB1).
E248 -0002 -04 Title EEPROM error
Detection description EEPROM writing error for the Reader Controller PCB (PCB1).
Remedy Failure of the Reader Controller PCB (PCB1).
E248 -0003 -04 Title EEPROM error
Detection description Reading error after writing to EEPROM for the Reader
Controller PCB (PCB1).
Remedy Failure of the Reader Controller PCB (PCB1).
E263 -0000 -05 Title Error in Current Sensor reference voltage generation
Detection description When CP54 on the Main Driver PCB was measured with a
tester, the reference voltage (normally 2.5 V) was not within the range of reference value (2.2 to 2.7 V).
Remedy 1. Check the connection between the AC Driver PCB and the Main Driver PCB (connector disconnection, open circuit, short circuit of harness). AC Driver side: J615, Main Driver side: J103
2. Replace the AC Driver PCB.
3. Replace the Main Driver PCB (PCB2).
E263 -0001 -05 Title Current Sensor error
Detection description An error is detected in the value of the Current Sensor (SE601)
(the value remains at the upper limit).
Remedy 1. Check the connection between the AC Driver PCB and the Main Driver PCB (connector disconnection, open circuit, short circuit of harness). AC Driver side: J615, Main Driver side: J103
2. Replace the AC Driver PCB.
3. Replace the Main Driver PCB (PCB2).
E263 -0002 -05 Title Current Sensor error
Detection description An error is detected in the value of the Current Sensor (SE601)
(the value remains at the lower limit).
Remedy 1. Check the connection between the AC Driver PCB and the Main Driver PCB (connector disconnection, open circuit, short circuit of harness).
AC Driver side: J615, Main Driver side: J103
2. Replace the AC Driver PCB.
3. Replace the Main Driver PCB (PCB2).
E270 -0001 -04 Title Error in paper front vertical scanning synchronous signal
Detection description Vertical scanning synchronous signal (VSYNC) is not sent
appropriately from the CMOS PCB (Scanner Unit (Paper
Front)), so the image error occurs or the operation stops abnormally.
Remedy 1. Connector disconnection/open circuit of the Scanner Unit (Reader).
2. Connector disconnection/open circuit of the Reader Controller PCB (PCB1).
3. Failure of the Scanner Unit (Reader).
4. Failure of the Reader Controller PCB (PCB1).
E270 -0002 -04 Title Error in horizontal scanning/vertical scanning synchronous signal
Detection description Due to the horizontal scanning synchronous signal (HSYNC)
error, the vertical scanning synchronous signal (VSYNC) is
not sent, so the image error occurs or the operation stops abnormally.
Remedy 1. Connector disconnection/open circuit of the Scanner Unit (Reader/DADF).
2. Connector disconnection/open circuit of the Reader Controller PCB (PCB1).
3. Failure of the Scanner Unit (Reader/DADF).
4. Failure of the Reader Controller PCB (PCB1).
E270 -0101 -04 Title Error in paper back vertical scanning synchronous signal
Detection description Vertical scanning synchronous signal (VSYNC) is not sent
appropriately from the CMOS PCB (Scanner Unit (Paper Back)), so the image error occurs or the operation stops abnormally.
Remedy 1. Connector disconnection/open circuit of the Scanner Unit (DADF).
2. Connector disconnection/open circuit of the Reader Controller PCB (PCB1).
3. Failure of the Scanner Unit (DADF).
4. Failure of the Reader Controller PCB (PCB1).
E280 -0001 -04 Title Communication error between Reader Controller PCB (PCB1) and Scanner Unit (Reader)
Detection description Within the specified period of time, communication between
the Reader Controller PCB and Scanner Unit (Paper Front) is not started.
Remedy 1. Connector disconnection/open circuit of the Scanner Unit (Reader).
2. Connector disconnection/open circuit of the Reader Controller PCB (PCB1).
3. Failure of the Scanner Unit (Reader).
4. Failure of the Reader Controller PCB (PCB1).
E280 -0101 -04 Title Communication error between Reader Controller PCB (PCB1)
and Scanner Unit (DADF)
Detection description Within the specified period of time, communication between
the Reader Controller PCB and Scanner Unit (Paper Back) is not started.
Remedy 1. Connector disconnection/open circuit of the Scanner Unit (DADF).
2. Connector disconnection/open circuit of the Reader Controller PCB (PCB1).
3. Failure of the Scanner Unit (DADF).
4. Failure of the Reader Controller PCB (PCB1).  