Tuesday, May 13, 2014

Canon ImageRunner Advance 8205 8295 8285,Errorcode E540 To E551 and Solution

http://www.partstron.com
E540 -8001 -05 Title a. Error in tray A (upper tray) (Finisher-Q1)
b. Tray 1 time out error (Finisher-N1)
Detection description
a. Tray A up/down motor rotation sensor does not come ON within 300 msec after the tray A up/down motor starts operation.
b. The tray 1 does not return to home position when the Tray 1 Shift Motor has been driven for 20 seconds. The tray 1 does not come off the Tray 1 Area Sensor at the same area when the Tray 1 Shift Motor has been driven for 4 seconds.
Remedy a-1. Connector check of tray A up/down motor rotation sensor
a-2. Connector check of tray A up/down motor
a-3. Replacement of tray A up/down motor rotation sensor
a-4. Replacement of tray A up/down motor
a-5. Replacement of finisher controller PCB
b-1. The connectors of the Tray 1 Area Sensors (S122/S123/ S124) or the Tray 1 Shift Motor (M105) are disconnected.
b-2. The wiring of the Tray 1 Area Sensors (S122/S123/S124) or the Tray 1 Shift Motor (M105) are faulty.
b-3. The Tray 1 Area Sensors (S122/S123/S124) is faulty.
b-4. The Tray 1 Shift Motor (M105) is faulty.
b-5. The Finisher Controller PCB is faulty.
E540 -8002 -05 Title a. Error in tray A (upper tray) (Finisher-Q1) b. Tray 1 area error (Finisher-N1)
Detection description
a. Detected position of tray A is below the tray B.
b. The tray 1 detects the discontinuous area with the Tray 1 Area Sensors.
Remedy a-1. Connector check of tray A area sensor
a-2. Replacement of tray A area sensor
a-3. Replacement of finisher controller PCB
b-1. The connectors of the Tray 1 Area Sensors (S122/S123/ S124) or the Tray 1 Shift Motor (M105) are disconnected.
b-2. The wiring of the Tray 1 Area Sensors (S122/S123/S124) or the Tray 1 Shift Motor (M105) are faulty.
b-3. The Tray 1 Area Sensors (S122/S123/S124) is faulty.
b-4. The Tray 1 Shift Motor (M105) is faulty.
b-5. The Finisher Controller PCB is faulty.
E540 -8003 -05 Title a. Error in tray A (upper tray) (Finisher-Q1)
b. Error in the Tray 1 Lower Safety Switch (Finisher-N1)
Detection description
a. Tray adjacent switch is activated.
b. The Tray 1 Lower Safety Switch is turned ON while the tray 1 operates.
Remedy a-1. Connector check of tray adjacent switch
a-2. Replacement of tray adjacent switch
a-3. Replacement of finisher controller PCB
b-1. The connector of the Tray 1 Lower Safety Switch (SW110) or the Tray 1 Shift Motor (M105) are disconnected.
b-2. The wiring of the Tray 1 Lower Safety Switch (SW110) or the Tray 1 Shift Motor (M105) are faulty.
b-3. The Tray 1 Lower Safety Switch (SW110) is faulty.
b-4. The Tray 1 Shift Motor (M105) is faulty.
b-5. The Finisher Controller PCB is faulty.
E540 -8013 -05 Title Error in the Swing Guide Safety Switch (Finisher-N1)
Detection description The Swing Guide Safety Switch (front/rear) is turned ON while
the tray 1 operates.
Remedy 1. The connector of the Swing Guide Safety Switch (front/rear)
(SW102/SW104) or the Staple Position Switch (SW103) are disconnected.
2. The connector of the Swing Guide Solenoid (SL101) or the Tray 1 Shift Motor (M105) are disconnected.
3. The wiring of the Swing Guide Safety Switch (front/rear) (SW102/SW104) or the Staple Position Switch (SW103) are faulty.
4. The wiring of the Swing Guide Solenoid (SL101) or the Tray 1 Shift Motor (M105) are faulty.
5. The Swing Guide Safety Switch (front/rear) (SW102/SW104) is faulty.
6. The Staple Position Switch (SW103) is faulty.
7. The Swing Guide Solenoid (SL101) is faulty.
8. The Tray 1 Shift Motor (M105) is faulty.
9. The Finisher Controller PCB is faulty.
E540 -80FF -05 Title Error in tray A (upper tray)
Detection description Up/down operation is not completed within 25 sec after the
tray A up/down motor starts operation.
Remedy 1. Connector check of tray A up/down motor rotation sensor
2. Connector check of tray A up/down motor
3. Replacement of tray A up/down motor rotation sensor
4. Replacement of tray A up/down motor
5. Replacement of finisher controller PCB
E542 -8001 -05 Title a. Error in tray B (lower tray) (Finisher-Q1) b. Tray 2 time out error (Finisher-N1)
Detection description
a. Tray B up/down motor rotation sensor does not come ON within 300 msec after the tray B up/down motor starts operation.
b. The tray 2 does not return to home position when the Tray 2 Shift Motor has been driven for 20 seconds. The tray 2 does not come off the Tray 2 Area Sensor at the same area when the Tray 2 Shift Motor has been driven for 4 seconds.
Remedy a-1. Connector check of tray B up/down motor rotation sensor
a-2. Connector check of tray B up/down motor
a-3. Replacement of tray B up/down motor rotation sensor
a-4. Replacement of tray B up/down motor
a-5. Replacement of finisher controller PCB
b-1. The connectors of the Tray 2 Area Sensors (S125/S126/S127) or the Tray 2 Shift Motor (M217) are disconnected.
b-2. The wiring of the Tray 2 Area Sensors (S125/S126/S127)or the Tray 2 Shift Motor (M217) are faulty.
b-3. The Tray 2 Area Sensors (S125/S126/S127) is faulty.
b-4. The Tray 2 Shift Motor (M217) is faulty.
b-5. The Finisher Controller PCB is faulty.
E542 -8002 -05 Title a. Error in tray B (lower tray) (Finisher-Q1)
b. Tray 2 area error (Finisher-N1)
Detection description
a. Detected position of tray B is above tray A.
b. The tray 2 detects the discontinuous area with the Tray 2 Area Sensors.
Remedy a-1. Connector check of tray B area sensor
a-2. Replacement of tray B area sensor
a-3. Replacement of finisher controller PCB
b-1. The connectors of the Tray 2 Area Sensors (S125/S126/ S127) or the Tray 2 Paper Sensor (S105) are disconnected.
b-2. The connector of the Tray 2 Shift Motor (M217) is disconnected.
b-3. The wiring of the Tray 2 Area Sensors (S125/S126/S127) or the Tray 2 Paper Sensor (S105) are faulty.
b-4. The wiring of the Tray 2 Shift Motor (M217) is faulty.
b-5. The Tray 2 Area Sensors (S125/S126/S127) is faulty.
b-6. The Tray 2 Paper Sensor (S105) is faulty.
b-7. The Tray 2 Shift Motor (M217) is faulty.
b-8. The Finisher Controller PCB is faulty.
E542 -8003 -05 Title a. Error in tray B (lower tray) (Finisher-Q1)
b. Error in the Tray 1 Lower Safety Switch (Finisher-N1)
Detection description a. Tray adjacent switch is activated.
b. The Tray 1 Lower Safety Switch is turned ON while the tray 2 operates.
Remedy a-1. Connector check of tray adjacent switch
a-2. Replacement of tray adjacent switch
a-3. Replacement of finisher controller PCB
b-1. The connector of the Tray 1 Lower Safety Switch (SW110)
or the Tray 2 Shift Motor (M217) are disconnected.
b-2. The wiring of the Tray 1 Lower Safety Switch (SW110) or
the Tray 2 Shift Motor (M217) are faulty.
b-3. The Tray 1 Lower Safety Switch (SW110) is faulty.
b-4. The Tray 2 Shift Motor (M217) is faulty.
b-5. The Finisher Controller PCB is faulty.
E542 -8013 -05 Title Error in the Swing Guide Safety Switch (Finisher-N1)
Detection description The Swing Guide Safety Switch (front/rear) is turned ON while
the tray 2 operates.
Remedy 1. The connector of the Swing Guide Safety Switch (front/rear) (SW102/SW104) or the Staple Position Switch (SW103) are disconnected.
2. The connector of the Swing Guide Solenoid (SL101) or the Tray 2 Shift Motor (M217) are disconnected.
3. The wiring of the Swing Guide Safety Switch (front/rear) (SW102/SW104) or the Staple Position Switch (SW103) are faulty.
4. The wiring of the Swing Guide Solenoid (SL101) or the Tray 2 Shift Motor (M217) are faulty.
5. The Swing Guide Safety Switch (front/rear) (SW102/ SW104) is faulty.
6. The Staple Position Switch (SW103) is faulty.
7. The Swing Guide Solenoid (SL101) is faulty.
8. The Tray 2 Shift Motor (M217) is faulty.
9. The Finisher Controller PCB is faulty.
E542 -80FF -05 Title Error in tray B (lower tray)
Detection description Up/down operation is not completed within 25 sec after the
tray B up/down motor starts operation.
Remedy 1. Connector check of tray B up/down motor rotation sensor
2. Connector check of tray B up/down motor
3. Replacement of tray B up/down motor rotation sensor
4. Replacement of tray B up/down motor
5. Replacement of finisher controller PCB
E544 -0001 -05 Title Error in Upper Neat Stack Unit Return Roller (Finisher-Q1)
Detection description The HP has not been detected within 1 second after the start
of the operation of the Lifting Motor of the Upper Neat Stack Unit Return Roller.
Remedy 1. Check for any disconnection/improper connection of the following connectors. => Disconnect and then connect them if necessary.
• Upper Neat Stack Unit Return Roller HP Sensor (PS209)
• Upper Neat Stack Unit Return Roller Lifting Motor (M209)
2. Replace the Upper Neat Stack Unit Return Roller HP Sensor.
3. Replace the Upper Neat Stack Unit Return Roller Lifting Motor.
4. Replace the Finisher Controller PCB (UN3).
E544 -0002 -05 Title Error in Upper Neat Stack Unit Return Roller (Finisher-Q1)
Detection description The roller does not move away from the HP within 1 second
after the start of the operation of the Lifting Motor of the Upper Neat Stack Unit Return Roller.
Remedy 1. Check for any disconnection/improper connection of the following connectors. => Disconnect and then connect them if necessary.
• Upper Neat Stack Unit Return Roller HP Sensor (PS209)
• Upper Neat Stack Unit Return Roller Lifting Motor (M209)
2. Replace the Upper Neat Stack Unit Return Roller HP Sensor.
3. Replace the Upper Neat Stack Unit Return Roller LiftingMotor.
4. Replace the Finisher Controller PCB (UN3).
E548 -0001 -05 Title Error in Lower Neat Stack Unit Return Roller (Finisher-Q1)
Detection description The HP has not been detected within 1 second after the start
of the operation of the Lifting Motor of the Lower Neat Stack Unit Return Roller.
Remedy 1. Check for any disconnection/improper connection of the
following connectors. => Disconnect and then connect them if necessary.
• Lower Neat Stack Unit Return Roller HP Sensor(PS208)
• Lower Neat Stack Unit Return Roller Lifting Motor(M208)
2. Replace the Lower Neat Stack Unit Return Roller HP Sensor.
3. Replace the Lower Neat Stack Unit Return Roller Lifting Motor.
4. Replace the Finisher Controller PCB (UN3).
E548 -0002 -05 Title Error in Lower Neat Stack Unit Return Roller (Finisher-Q1)
Detection description The roller does not move away from the HP within 1 second
after the start of the operation of the Lifting Motor of the Lower Neat Stack Unit Return Roller.
Remedy 1. Check for any disconnection/improper connection of the following connectors. => Disconnect and then connect them if necessary.
• Lower Neat Stack Unit Return Roller HP Sensor (PS208)
• Lower Neat Stack Unit Return Roller Lifting Motor (M208)
2. Replace the Lower Neat Stack Unit Return Roller HP Sensor.
3. Replace the Lower Neat Stack Unit Return Roller Lifting Motor.
4. Replace the Finisher Controller PCB (UN3).
E551 -0001 -05 Title a. Error in power fan of the integration unit b. Error in Power Supply Cooling Fan (Document Insertion Unit-K1) c. Error in the Power Supply Fan of the Finisher (Finisher-N1)
Detection description b. The lock detection signal is detected ON while the Power
Supply Cooling Fan is driven, or the fan lock detection signal is detected OFF while the Power Supply Cooling Fan is stopped.
c. The loch signal is detected 1.2 sec. or more while the fan operates.
Remedy a-1. Contact failure on connector of power fan (FM1)
a-2. Failure of power fan (FM1)
b-1. Connector of the Power Supply Cooling Fan (F1) is disconnected
b-2. Power Supply Cooling Fan (F1) is faulty
c-1. The connector of the Power Supply Fan (FAN101) is disconnected.
c-2. The wiring of the Power Supply Fan (FAN101) is faulty.
c-3. The Power Supply Fan (FAN101) is faulty.
c-4. The Finisher Controller PCB is faulty.
E551 -0001 -05 Title Error in power fan
Detection description Fan lock detection signal is detected ON.
Remedy 1. Contact failure on connector of power fan (FM1) on the integration unit
2. Failure of power fan (FM1) on the integration unit
E551 -0001 -05 Title Error in power supply fan (F1) of the insertion unit
Detection description Fan lock detection signal is detected ON while the power
supply fan is driven
Remedy 1. Power supply fan is faulty 2. Connector of the power supply fan is disconnected
E551 -0002 -05 Title a. Error in Power Supply Cooling Fan of Paper Folding Unit
(Paper Folding Unit-H1) b. Error in the Power Supply Fan of the Finisher (Finisher-N1)
Detection description a. The lock detection signal is detected ON while the Power Supply Cooling Fan is driven, or the fan lock detection signal is detected OFF while the Power Supply Cooling Fan is stopped.
b. The lock status is released when the fan stops.
Remedy a-1. Connector of the Power Supply Cooling Fan (F1) is disconnected
a-2. Power Supply Cooling Fan (F1) is faulty
b-1. The connector of the Power Supply Fan (FAN101) is disconnected.
b-2. The wiring of the Power Supply Fan (FAN101) is faulty.
b-3. The Power Supply Fan (FAN101) is faulty.
b-4. The Finisher Controller PCB is faulty.
E551 -0002 -05 Title Error in power fan on the integration unit
Detection description The lock status is released when the fan stops.
Remedy 1. Contact failure on connector of power fan (FM1)
2. Failure of power fan (FM1)
E551 -0004 -05 Title Cooling fan (F1) error in paper folding unit
Detection description Power fan lock signal is detected.
Remedy 1. Disconnection of connector on cooling fan 2. Breakage of cooling fan
E551 -0011 -05 Title Error in the Power Supply Fan of the Insertion Unit
Detection description The loch signal is detected for the specified times while the fan
operates.
Remedy 1. The connector of the Fan (F1) is disconnected.
2. The wiring of the Fan (F1) is faulty.
3. The Fan (F1) is faulty.   4. The Insertion Unit Controller PCB is faulty.
E551 -0011 -05 Title Error in the Power Supply Fan of the Insertion Unit
Detection description The loch signal is detected for the specified times while the fan operates.
Remedy 1. The connector of the Fan (F1) is disconnected.
2. The wiring of the Fan (F1) is faulty. 3. The Fan (F1) is faulty.
4. The Insertion Unit Controller PCB is faulty.
E551 -0021 -05 Title Error in the Power Supply Fan of the Paper Folding Unit
Detection description The loch signal is detected for the specified times while the fan
operates.
Remedy 1. The connector of the Fan (F1) is disconnected.
2. The wiring of the Fan (F1) is faulty.  3. The Fan (F1) is faulty.
4. The Paper Folding Unit Controller PCB is faulty.
http://www.partstron.com

1 comment: