Sunday, May 11, 2014

Canon ImageRunner Advance 8105 8095 8085,Errorcode E604 To E0677 and Solution


http://www.partstron.com





 

E604 -1024 -00 Title Insufficient memory
Remedy DDR2-SDRAM
Description Insufficient memory (require 1024 MB).
E609 -0008 -00 Title Hard disk error
Remedy HDD.
Description Temperature of the HDD does not rise to the specified temperature within the specified period of time at the time of startup.
E609 -0009 -00 Title Hard disk error
Remedy HDD.
Description At the time of recovery from sleep, it does not reach to the specified temperature.
E610 -0001 -00 Title Failure of the HDD encryption key (hardware configuration
error/initialization error/encryption key error/encryption processing error)
Remedy Check the hardware configuration.
Description The Encryption Board does not exist.
E610 -0002 -00 Title Failure of the HDD encryption key (hardware configuration
error/initialization error/encryption key error/encryption processing error)
Remedy Check the hardware configuration.
Description Not meeting the memory configuration to execute encryption operation.
E610 -0101 -00 Title Failure of the HDD encryption key (hardware configuration
error/initialization error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power.
Description Failed to initialize the memory of key storage area.
E610 -0102 -00 Title Failure of the HDD encryption key (hardware configuration
error/initialization error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power.
Description Failed to initialize the encryption processing part.
E610 -0201 -00 Title Failure of the HDD encryption key (hardware configuration
error/initialization error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power.
Description Error in the encryption processing part.
E610 -0202 -00 Title Failure of the HDD encryption key (hardware configuration
error/initialization error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power.
Description Error in the encryption processing part.
E610 -0301 -00 Title Failure of the HDD encryption key (hardware configuration
error/initialization error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power.
Description Failed to create the encryption key.
E610 -0302 -00 Title Failure of the HDD encryption key (hardware configuration
error/initialization error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power. Due to this error, HDD content is initialized.
Description Failure of the encryption key is detected.
E610 -0303 -00 Title Failure of the HDD encryption key (hardware configuration
error/initialization error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power. Due to this error, HDD content is initialized.
Description Failure of the encryption key is detected.
E610 -0401 -00 Title Failure of the HDD encryption key (hardware configuration
error/initialization error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power.
Description Error is detected during encryption.
E610 -0402 -00 Title Failure of the HDD encryption key (hardware configuration
error/initialization error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power.
Description Error is detected during decryption.
E610 -0501 -00 Title Failure of the HDD encryption key (hardware configuration
error/initialization error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power.
Description Error in document management information on /FSTDEV.
E611 -0000 -00 Title Rebooting due to SRAM corruption when executing a
transmission job that secures disconnection of the power
Remedy Clear SRAM to erase the job that secures disconnection of the power.
Description In the case that reboot is repeated at recovery from power down because SRAM information is corrupted and the job information saved on SRAM cannot be read, the phenomenon
that the communication is repeated occurs.
E677 -0001 -00 Title Print server error
Remedy 1. Check power supply to the Exhaust Fan. 2. Replace the Exhaust Fan.
Description Exhaust Fan operation error on the print server is detected.
E677 -0003 -00 Title Print server error
Remedy Check the cable connection, reinstallation.
Description Error is detected at the configuration check performed at startup.
E677 -0004 -00 Title Print server error
Remedy 1. Check power supply to the CPU Fan. 2. Replace the CPU Fan.
Description CPU Fan operation error on the print server is detected.
E677 -0010 -00 Title Print server error
Remedy Replace the print server with the proper one.
Description Not proper print server is connected.
E677 -0080 -00 Title Print server error
Remedy Check the cable connection, reinstallation.
Description Communication error at startup





http://www.partstron.com 

No comments:

Post a Comment