Remedy DDR2-SDRAM
Description Insufficient memory (require 1024 MB).
E609 -0008 -00 Title Hard
disk error
Remedy HDD.
Description Temperature of the HDD does not rise to the
specified temperature within the specified period of time at the time of startup.
E609 -0009 -00 Title Hard
disk error
Remedy HDD.
Description At the time of recovery from sleep,
it does not reach to the specified temperature.
E610 -0001 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization
error/encryption key error/encryption processing error)
Remedy Check
the hardware configuration.
Description The Encryption Board does not exist.
E610 -0002 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization
error/encryption key error/encryption processing error)
Remedy Check
the hardware configuration.
Description Not
meeting the memory configuration to execute encryption operation.
E610 -0101 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization
error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power.
Description Failed to initialize the memory of
key storage area.
E610 -0102 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization
error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power.
Description Failed to initialize the encryption
processing part.
E610 -0201 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization
error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power.
Description Error in the encryption processing part.
E610 -0202 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization
error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power.
Description Error in the encryption processing
part.
E610 -0301 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization
error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power.
Description Failed to create the encryption
key.
E610 -0302 -00 Title Failure of the HDD encryption key (hardware
configuration
error/initialization
error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power. Due to this error, HDD
content is initialized.
Description Failure of the encryption key is
detected.
E610 -0303 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization
error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power. Due
to this error, HDD content is initialized.
Description Failure of the encryption key is
detected.
E610 -0401 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization
error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power.
Description Error is detected during
encryption.
E610 -0402 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization
error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power.
Description Error is detected during
decryption.
E610 -0501 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization
error/encryption key error/encryption processing error)
Remedy Turn OFF and then ON the power.
Description Error in document management information on /FSTDEV.
E611 -0000 -00 Title
Rebooting due to SRAM corruption when executing a
transmission job that
secures disconnection of the power
Remedy Clear SRAM to erase the job that secures disconnection
of the power.
Description In the case that reboot is repeated
at recovery from power down because SRAM information is corrupted and the job information
saved on SRAM cannot be read, the phenomenon
that the communication is repeated
occurs.
E677 -0001 -00 Title Print
server error
Remedy 1. Check power supply to the Exhaust
Fan. 2. Replace the Exhaust Fan.
Description Exhaust Fan operation error on the
print server is detected.
E677 -0003 -00 Title Print
server error
Remedy Check the cable connection,
reinstallation.
Description Error
is detected at the configuration check performed at startup.
E677 -0004 -00 Title Print
server error
Remedy 1. Check power supply to the CPU Fan. 2. Replace the CPU
Fan.
Description CPU Fan operation error on the
print server is detected.
E677 -0010 -00 Title Print
server error
Remedy Replace the print server with the
proper one.
Description Not proper print server is
connected.
E677 -0080 -00 Title Print
server error
Remedy Check the cable connection,
reinstallation.
Description Communication error at startup