E060 -0001 -05 Title Primary Charging Shutter HP open error
Detection description The Primary Charging Shutter Sensor (PS94) detects that the
shutter
is opened although it is moved to the close position.
Remedy
1.
Check the position of the Primary Charging Shutter and the Cleaning Pad.
1-A.
In the case that the Primary Charging Shutter and the Cleaning Pad fail to operate (stopped at HP at
front side)
1-A-1.
Check the connection of the Primary Charging Wire Cleaning Motor (M6).
Motor
side: J3017, J3060 (iR-ADV 8xxx)/J3160 (Iradv 6xxx) (relay), PCB side: J3177 (relay), J107
(Main
Driver
PCB (PCB2))
1-A-2.
Replace the Primary Charging Wire Cleaning Motor (M6).
1-B.
In the case that the Primary Charging Shutter and the Cleaning Pad are stopped at rear side (close
operation position)
1-B-1.
Check the connection of the Primary Charging Shutter Sensor (PS94). Sensor side: J2029, J3089 (relay), PCB side:
J3088 (relay), J114 (Main Driver PCB (PCB2))
1-B-2.
Replace the Primary Charging Shutter Sensor (PS94).
1-C.
In the case that the Primary Charging Shutter and the Cleaning Pad are stopped along the way
1-C-1.
Check the loosening of screw on the Slider Pin and abrasion of the pin. Tighten the screw or
replace the Slider Pin.
1-C-2.
Replace the Primary Charging Assembly.
1-D.
In the case that the Primary Charging Shutter stops at front side and the Cleaning Pad moves to rear
side
1-D-1.
Check if the Shutter Mounting Plate is deformed. If so, replace the Shutter Unit.
1-D-2.
Check the loosening of screw on the Slider Pin and abrasion of the pin. Tighten the screw or
replace the Slider Pin.
1-D-3.
Replace the Primary Charging Assembly.
2.
Replace the Main Driver PCB (PCB2).
3. Replace the DC
Controller PCB (PCB1).
E060 -0002 -05 Title Primary Charging Shutter HP close error
Detection description The Primary Charging Shutter Sensor (PS94) detects that the
shutter
is closed although it is moved to the open position.
Remedy
1.
Check the position of the Primary Charging Shutter and the Cleaning Pad.
1-A.
In the case that the Primary Charging Shutter and the Cleaning Pad fail to operate (stopped at HP at
front side)
1-A-1.
Check the connection of the Primary Charging Wire Cleaning Motor (M6).
Motor
side: J3017, J3060 (iR-ADV 8xxx)/J3160 (iRADV 6xxx) (relay), PCB side: J3177 (relay), J107
(Main Driver PCB (PCB2))
1-A-2.
Replace the Primary Charging Wire Cleaning Motor (M6).
1-B.
In the case that the Primary Charging Shutter and the Cleaning Pad are stopped at rear side (close
operation position)
1-B-1.
Check the connection of the Primary Charging Shutter Sensor (PS94).
Sensor
side: J2029, J3089 (relay), PCB side: J3088 (relay), J114 (Main Driver PCB (PCB2))
1-B-2.
Replace the Primary Charging Shutter Sensor (PS94).
1-C.
In the case that the Primary Charging Shutter and the Cleaning Pad are stopped along the way
1-C-1.
Check the loosening of screw on the Slider Pin and abrasion of the pin. Tighten the screw or
replace the Slider Pin.
1-C-2.
Replace the Primary Charging Assembly.
2.
Replace the Main Driver PCB (PCB2).
3. Replace the DC
Controller PCB (PCB1).
E061 -0001 -05 Title Potential control error (VL)
Detection description The measured value in the dark area (VL) differs +/-30 V or
higher
than the target potential at potential control.
NOTE: If the difference is somewhere between +/-10 V and less than 30 V, alarm is indicated.
Remedy 1. Check the connection of the Pre-exposure LED
(connector connection, open circuit, the caught cable).
2.
Check the installation of the Primary Charging Assembly (connector connection, open circuit, the caught
cable).
3.
Check the fixation state of the Drum and the Drum Shaft. (Check if the drum
fixation cylinder is properly installed.)
4.
Check if the Dustproof Glass is soiled. If necessary, clean it.
5.
Check the installation of the Laser Scanner Unit (connector connection, open circuit,
the caught cable).
6.
Check the installation of the Primary Charging High Voltage PCB (PCB11), and its
connection (connector connection, open circuit, the caught cable).
7.
Check the installation of the Potential Sensor (connector connection, open circuit,
the caught cable).
8.
Check the installation of the Drum Motor (M1), and its connection (connector connection, open circuit,
the caught cable).
9.
Replace the parts. • Primary Charging Assembly • Laser Scanner Unit • Potential Sensor • Primary Charging High
Voltage PCB (PCB11) • Drum Motor (M1) • Main Driver PCB (PCB2) • DC Controller PCB (PCB1)
E061 -0101 -05 Title Potential control error (VD)
Detection description Potential in the dark area did not fall within the range (target value +/-10 V) although retry was executed 8
times at VD potential control.
Remedy 1. Check the connection of the Pre-exposure LED
(connector connection, open circuit, the caught cable).
2.
If the current value of the Primary Charging Roller (COPIER> DISPLAY> DPOT>
PRIM-C) is 1550 micro A or higher, execute 2-1 to 3.
2-1.
Increase the grid voltage of the Primary Charging Assembly by 100 V (COPIER> ADJUST>
HV-PRI>PRI-GRID).
2-2.
Execute the potential control (COPIER>FUNCTION> DPC> DPC).
2-3.
Turn OFF and then ON the power.
3.
Check the installation of the Primary Charging Assembly (connector connection, open circuit, the caught
cable).
4.
Check the installation of the Primary Charging High Voltage PCB (PCB11), and its
connection (connector connection, open circuit, the caught cable).
5.
Check the installation of the Drum Motor (M1), and its connection (connector connection, open circuit,
the caught cable).
6.
Replace the parts.• Primary Charging Assembly• Primary Charging High Voltage
PCB
•
Drum Motor (M1)• Main Driver PCB (PCB2)• DC Controller PCB (PCB1)
E064 -00FF -05 Title High voltage setting error
Detection description With the state in which the developing AC is output, 600 V or
higher
developing DC output was detected. (Basically, this error is not detected. However,
to detect that
the
image formation-related backup data is corrupted or to protect the hardware in case of 600 V or higher
developing DC output, this is to be an error.)
Remedy 1. Turn OFF and then ON the main power. 2. Replace the DCON PCB.
E065 -0001 -05 Title Primary charging/grid high voltage output leak error
Detection description The leak detection signal was detected 5 times in a row for
every
20 msec.
Remedy 1. Check the connection between the Main Driver
PCB (PCB2) and the High Voltage Unit.
Main
Driver side: J111, High Voltage Unit side: J3097
2.
Check the connection between the Relay PCB (PCB5) and
the
High Voltage Unit.
Relay
side: J519, High Voltage Unit side: J3099
3.
Replace the Primary Charging Assembly.
4.
Check the connection inside of the High Voltage Unit. High Voltage Unit Relay (J3097) and Primary
Charging High Voltage PCB (PCB11) (J3501) High Voltage Unit relay (J3099) and Pre-transfer
Charging
PCB
(PCB26) (J3545, J3500)
5.
Replace the Main Driver PCB (PCB2).
6.
Replace the Primary Grid High Voltage Connector (FM4-1006).
E066 -0001 -05 Title Pre-transfer Charging Shutter HP open error
Detection description The Pre-transfer Charging Shutter Sensor (PS95) detects
that
the shutter is opened although it is moved to the close position.
Remedy
1.
Check the position of the Pre-transfer Charging Shutter.
1-A.
In the case that the Pre-transfer Charging Shutter fails to operate (stopped at HP at
front side) Check the connection of the Pre-transfer Charging Wire Cleaning Motor (M7). Sensor side: J3108, J3089
(relay), PCB side: J3088 (relay), J114 (Main Driver PCB (PCB2))
1-B.
In the case that the Pre-transfer Charging Shutter is stopped at rear side (close operation position)
1-B-1.
Check that the Primary Fan Duct is closed. Closethe Primary Fan Duct.
1-B-2.
Check movement of the pin to push the Pretransfer Charging Shutter Sensor (PS95). Replace the
Pin.
1-B-3.
Check movement of the flag on the Pre-transfer Charging Shutter Sensor (PS95). Replace the
flag/spring.
1-B-4.
Check the connection of the Pre-transfer Charging Shutter Sensor (PS95). Sensor side: J2114, J3215 (relay), J3067 (relay)
PCB side: J3066 (relay), J130 (Main Driver PCB (PCB2))
1-C.
In the case that the Pre-transfer Charging Shutter is stopped along the way
1-C-1.
Check abrasion of the Slider Pin. Replace the Slider Pin.
1-C-2.
Replace the Pre-transfer Charging Assembly.
2.
Replace the DC Controller PCB (PCB1).
E066 -0002 -05 Title Pre-transfer Charging Shutter HP close error
Detection description The Pre-transfer Charging Shutter Sensor (PS95) detects that
the
shutter is closed although it is moved to the open position.
Remedy
1.
Check the position of the Pre-transfer Charging Shutter.
1-A.
In the case that the Pre-transfer Charging Shutter fails to operate (stopped at HP at
front side)
Check
the connection of the Pre-transfer Charging Wire Cleaning Motor (M7). Sensor side: J3108, J3089 (relay), PCB side:
J3088 (relay), J114 (Main Driver PCB (PCB2))
1-B.
In the case that the Pre-transfer Charging Shutter is stopped at rear side (close operation position)
1-B-1.
Check that the Primary Fan Duct is closed. Close the Primary Fan Duct.
1-B-2.
Check movement of the pin to push the Pretransfer Charging Shutter Sensor (PS95). Replace the
Pin.
1-B-3.
Check movement of the flag on the Pre-transfer Charging Shutter Sensor (PS95). Replace the
flag/spring.
1-B-4.
Check the connection of the Pre-transfer Charging Shutter Sensor (PS95). Sensor side: J2114, J3215 (relay), J3067 (relay)
PCB side: J3066 (relay), J130 (Main Driver PCB (PCB2))
1-C.
In the case that the Pre-transfer Charging Shutter is stopped along the way
1-C-1.
Check abrasion of the Slider Pin. Replace the Slider Pin.
1-C-2.
Replace the Pre-transfer Charging Assembly.
2.
Replace the DC Controller PCB (PCB1 3099) and Pre-transfer Charging PCB (PCB26) (J3545,
J3500)
E067 -0001 -05 Title Developing high voltage output leak error
Detection description The leak detection signal was detected 5 times in a row for every 20 msec.
Remedy 1. Check the connection between the Main Driver
PCB (PCB2) and the High Voltage Unit.
Main
Driver side: J112, High Voltage Unit side: J3098
2.
Check the connection between the Relay PCB (PCB5) and the High Voltage Unit. Relay side: J519, High Voltage Unit side: J3099
3.
Replace the Developing Assembly.
4.
Check the connection point of the Developing Assembly.If it is soiled, clean
it.
5.
Check the connection inside of the High Voltage Unit. Check the connection of the High Voltage Unit
Relay (J3097) and the Developing High Voltage PCB (J3511). High Voltage Unit Relay (J3099) and Pre-transfer
Charging PCB (J3545, J3500, J3510)
6.
Replace the Main Driver PCB (PCB2).
E068 -0001 -05 Title Pre-transfer charging high voltage output leak error
Detection description The leak detection signal was detected 5 times in a row for
every
20 msec.
Remedy 1. Check the connection between the Main Driver
PCB (PCB2) and the High Voltage Unit.
Main
Driver side: J112, High Voltage Unit side: J3098
2.
Check the connection between the Relay PCB (PCB5) and the High Voltage Unit.
Relay
side: J519, High Voltage Unit side: J3099
3.
Replace the Pre-transfer Charging Assembly.
4.
Check the connection inside of the High Voltage Unit. Check the connection of the High Voltage Unit
Relay (J3098) and the Transfer High Voltage PCB (J3544). Check the connection of the High Voltage Unit
Relay (J3099) and the Pre-transfer Charging PCB (J3545, J3500)
5.
Replace the Main Driver PCB (PCB2).
6.
Replace the Pre-transfer High Voltage Connector (FM4-1007).
7.
Replace the Pre-transfer Transformer (Post Charging Trance) of the High Voltage Unit.
E069 -0001 -05 Title Transfer high voltage output leak error
Detection description The leak detection signal was detected 5 times in a row for
every
20 msec.
Remedy
1.
Check the connection between the Duplex Driver PCB (PCB4) and the High Voltage Unit.
Check
the connection at Duplex Driver side (J343) and the Transfer High Voltage side (J3066).
Check
the connection at Duplex Driver side (J311) and the Transfer High Voltage side (J3061). (In addition,
check that 24 V is output.)
2.
Check the connection of the Transfer High Voltage PCB(J3306).
3.
Replace the ETB Unit.
No comments: