Remedy 1. Check the connection of the
Connector. Motor side: J2319, Main Driver PCB (PCB2) side: J109
2. Check the voltage of the
Developing Motor (M2) J2152.
If voltage is 0V, check the
connection of the Relay PCB J520.
3. Check the load of the Developing
Motor (M2). Manually turn the Developing Motor (M2) located at the
rear of the host machine to check
it.
4. Replace the Developing Motor
(M2).
5. Replace the Developing Clutch
(CL1). (When an error occurs while the Developing Clutch is ON.)
6. Replace the Main Driver PCB
(PCB2).
7. Replace the DC Controller PCB
(PCB1).
Description
Lock error of the Developing Motor (M2).
E023 -0002 -05 Title Error
in Magnet Roller Clutch connection detection
Remedy 1. Check the connection of the
Magnet Roller Clutch (CL5). Sensor side: J2006, Main Driver PCB (PCB2) side:
J109
2. Replace the Magnet Roller Clutch
(CL5).
3. Replace the Main Driver PCB
(PCB2).
4. Replace the DC Controller PCB
(PCB1).
Description Connection of the Magnet Roller
Clutch (CL5) cannot be detected 5 times with 20 msec time interval.
E025 -0001 -05 Title Toner
Feed Motor error
Remedy 1. Check the connection of the Connector. Motor side:
J2036, Buffer Unit relay: J3124, Front side
relay: J3090, Rear side relay:
J3091, Main Driver PCB (PCB2) side: J115
2. Replace the Toner Feed Motor
(M28).
3. Check if toner is clogged inside
of the Buffer.
Turn the Drive Shaft of the Motor
with your hand to check
it. If the load is too much, inside
of the Buffer may be
clogged, so clean inside of it.
4. Replace the Main Driver PCB
(PCB2).
5. Replace the DC Controller PCB
(PCB1).
Description Overcurrent of the Toner Feed Motor
(M28) was detected.
E027 -0001 -05 Title Toner
Supply Motor error
Remedy 1. Check the connection of the
Connector. Motor side: J2037, Front side relay: J3080, Rear side relay:
J3063, Main Driver PCB (PCB2) side:
J117
2. Remove the Toner Container, and
check if an error occurs. If an error does not occur, reinstall the Toner
Container and check again. If an error occurs, check the driving area of connection
point of the container. If an error occurs, go on to 3.
3. Replace the Toner Supply Motor
(M10).
4. Replace the Main Driver PCB
(PCB2).
5. Replace the DC Controller PCB
(PCB1).
Description Lock error of the Toner Supply
Motor (M10).
E032 -0001 -00 Title
Failure of NE Controller Counter
Remedy Disconnection of cable.
Description Detection of open circuit of count
pulse signal.
E041 -0001 -05 Title Right
Deck Lifter Motor error
Remedy 1. Check for displacement of the
Lifter Wire of the Right Deck.
2. Check for hindrance to smooth
movement of the Deck Base Plate of the Right Deck.
Description Overcurrent of the Right Deck Lifter Motor was detected.
E041 -0002 -05 Title Left
Deck Lifter Motor error
Remedy 1. Check for displacement of the
Lifter Wire of the Left Deck.
2. Check for hindrance to smooth
movement of the Deck Base Plate of the Left Deck.
Description Overcurrent of the Left Deck Lifter
Motor was detected.
E041 -0003 -05 Title
Cassette 3 Lifter Motor error
Remedy 1. Check for error around the Lifter of the Cassette 3.
2. Check for hindrance to smooth
movement of the Cassette Base Plate of the Cassette 3.
Description Overcurrent of the Cassette 3
Lifter Motor was detected.
E041 -0004 -05 Title Cassette
4 Lifter Motor error
Remedy 1. Check for error around the Lifter
of the Cassette 4.
2. Check for hindrance to smooth
movement of the Cassette Base Plate of the Cassette 4.
Description Overcurrent of the Cassette 4 Lifter
Motor was detected.
E053 -0001 -05 Title Error
in Reverse Upper Flapper Solenoid connection detection
Remedy 1. Check the connection of the Reverse Upper Flapper Solenoid
(SL5).
Solenoid side: J2115, Duplex Driver
PCB side: J340
2. Replace th e Reverse Upper
Flapper Solenoid (SL5).
3. Replace the Duplex Driver PCB
(PCB4).
4. Replace the DC Controller PCB
(PCB1).
Description Connection of the Reverse Upper
Flapper Solenoid (SL5) cannot be
detected 5 times with 20 msec time interval.
No comments: