Detection description Insufficient memory (require 1024 MB).
Remedy DDR2-SDRAM
E609-0008 -00 Title Hard disk error
Detection description Temperature of the HDD
does not rise to the specified
temperature within the specified period of time at the time of startup.
Remedy HDD.
E609-0009 -00 Title Hard disk error
Detection description
At the time of recovery from sleep, it does not reach to the specified temperature.
Remedy HDD.
E610-0001 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization error/encryption key
error/encryption processing
error)
Detection description The Encryption Board does not exist.
Remedy Check the hardware
configuration.
E610-0002 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization error/encryption key
error/encryption processing
error)
Detection description
Not meeting the memory configuration to execute encryption operation.
Remedy Check the hardware
configuration.
E610-0101 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization error/encryption key
error/encryption processing
error)
Detection description Failed to initialize the memory of key storage area.
Remedy Turn OFF and then ON the
power.
E610-0102 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization error/encryption key
error/encryption processing
error)
Detection description Failed to initialize the encryption processing part.
Remedy Turn OFF and then ON the
power.
E610-0201 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization error/encryption key
error/encryption processing
error)
Detection description Error in the encryption processing part.
Remedy Turn OFF and then ON the power.
E610-0202 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization error/encryption key
error/encryption processing
error)
Detection description Error in the encryption processing part.
Remedy Turn OFF and then ON the
power.
E610-0301 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization error/encryption key
error/encryption processing
error)
Detection description Failed to create the encryption key.
Remedy Turn OFF and then ON the
power.
E610-0302 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization error/encryption key
error/encryption processing
error)
Detection description Failure of the encryption key is detected.
Remedy Turn OFF and then ON the
power.
Due to this error, HDD content is initialized.
E610-0303 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization error/encryption key
error/encryption processing
error)
Detection description Failure of the encryption key is detected.
Remedy Turn OFF and then ON the
power. Due to this error, HDD content is initialized.
E610-0401 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization error/encryption key error/encryption processing error)
Detection description Error is detected during encryption.
Remedy Turn OFF and then ON the
power.
E610-0402 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization error/encryption key error/encryption processing error)
Detection description Error is detected during decryption.
Remedy Turn OFF and then ON the
power.
E610-0501 -00 Title Failure of the HDD encryption key
(hardware configuration
error/initialization error/encryption key error/encryption processing error)
Detection description Error in document management information on /FSTDEV.
Remedy Turn OFF and then ON the power.
E611-0000 -00 Title Rebooting due to SRAM corruption when
executing a transmission job that secures
disconnection of the power
Detection description In the case that reboot is repeated at recovery from
power
down because SRAM information is corrupted and the job information saved on SRAM cannot be read, the phenomenon that the communication is repeated occurs.
Remedy Clear SRAM to erase the
job that secures disconnection of the power.
E674-0001 -00 Title FAX error
Detection description Communication error with
the FAX PCB.
Remedy Check the cable
connection, replace the FAX PCB, replace the
Main Controller PCB.
E674-0002 -00 Title FAX error
Detection description Communication error with the FAX PCB.
Remedy Check the cable
connection, replace the FAX PCB, replace the
Main Controller PCB.
E674-0004 -00 Title FAX error
Detection description Error in access of the modem IC.
Remedy Check the cable
connection, replace the FAX PCB, replace the
Main Controller PCB.
E674-0008 -00 Title FAX error
Detection description Error in access of the port IC.
Remedy Check the cable
connection, replace the FAX PCB, replace
the Main Controller PCB.
E674-000C -00 Title FAX error
Detection description Error in access of the modem IC/port IC.
Remedy Check the cable
connection, replace the FAX PCB, replace
the Main Controller PCB.
E674-0010 -00 Title FAX error
Detection description FAX error.
Remedy Replace the Main
Controller PCB.
E674-0011 -00 Title FAX error
Detection description FAX error.
Remedy Replace the Main
Controller PCB.
E674-0030 -00 Title FAX error
Detection description Checksum error.
Remedy Download the system software for 2-line FAX.
E674-0100 -00 Title FAX error
Detection description Logging is failed after completion of FAX communication,
and
unable to read.
Remedy Turn OFF and then ON the
power.
E674-0200 -00 Title HDD access error
Detection description An error occurred when accessing the HDD.
Remedy 1. Turn OFF/ON the main
power switch.
2. Reinstall all the formats and the system. 3.
Replace the HDD.
4. Replace the Main Controller PCB 1.
E677-0001 -00 Title Print server error
Detection description Exhaust Fan operation
error on the print server is detected.
Remedy 1. Check power supply to
the Exhaust Fan. 2. Replace the Exhaust
Fan.
E677-0003 -00 Title Print server error
Detection description Error is detected at the configuration check performed at startup.
Remedy Check the cable
connection, reinstallation.
E677-0004 -00 Title Print server error
Detection description CPU Fan operation error on the print server is detected.
Remedy 1. Check power supply to
the CPU Fan. 2. Replace the CPU Fan.
E67-0010 -00 Title Print server error
Detection description Not proper print server is connected.
Remedy Replace the print server
with the proper one.
E677-0080 -00 Title Print server error
Detection description Communication error at startup.
No comments: