Remedy Connector disconnection, failure of Fan.
Description Error in the Power Supply Cooling
Fan is detected.
E804 -0000 -05 Title Power
Supply Cooling Fan 1/2 error
Remedy 1. Check the connection of the
Connector.
2. Replace the Power Supply Cooling
Fan 1 (FM14)/Power Supply Cooling Fan 2 (FM15).
Description The Fan stop signal is detected for
5 seconds or longer and retry is failed 4 times in a row although the Power
Supply Cooling Fan 1 (FM14)/Power Supply Cooling Fan 2 (FM15) is turned ON.
The error detection signal cable is
shared with the Fans, and it is not detected with which Fan the error occurs.
E804 -0001 -05 Title
Fixing Power Supply Cooling Fan error
Remedy 1. Check the connection of the
Connector.
2. Replace the Fixing Power Supply
Cooling Fan (FM7).
Description The Fan stop signal is detected for
1.5 seconds or longer and retry is failed 4 times in a row although the Fixing
Power Supply Cooling Fan (FM7) is turned ON.
E806 -0000 -05 Title
Making Image Exhaust Fan error
Remedy 1. Check the connection of the Connector.
2. Replace the Making Image Exhaust
Fan (FM3).
Description The Fan stop signal is detected for
5 seconds or longer and retry is failed 4 times in a row although the Making
Image Exhaust Fan (FM3) is turned ON.
E808 -0001 -05 Title
Fixing Power Supply error
Remedy 1. Check the outlet voltage. ->
Connect to the correct outlet.
2. Check the connection between the
Main Driver PCB (PCB2) and the Fixing Power Supply PCB (PCB10).
3. Replace the Fixing Power Supply
PCB (PCB10).
4. Replace the Main Driver PCB
(PCB2).
Description Detected 290V or higher inlet
voltage at power-on.
E808 -0002 -05 Title
Fixing Power Supply error
Remedy 1. Check the outlet voltage. -> Connect to the
correct outlet.
2. Check the connection between the
Main Driver PCB (PCB2)
and the Fixing Power Supply PCB
(PCB10).
3. Replace the Fixing Power Supply
PCB (PCB10).
4. Replace the Main Driver PCB
(PCB2).
Description Detected 50 V or lower inlet voltage at power-on.
E808 -0003 -05 Title
Fixing Power Supply error
Remedy 1. Check the clogging of the Fixing
Power Supply Cooling Fan (FM7).
2. Check the clogging of the Louver
on right side of the host machine (Multi-purpose Tray side).
3. Check the connection of the
Fixing Power Supply PCB (PCB10) Output Connector.
4. Replace the Fixing Power Supply
PCB (PCB10).
Description Inlet current is 1A or lower for 1
second or longer although the maximum voltage is output.
E808 -0004 -05 Title
Fixing Power Supply error
Remedy Replace the Main Driver PCB (PCB2).
Description Detected OFF with 12V of the Main
Driver PCB (PCB2) output.
E808 -0005 -05 Title 12V
OFF detection when relay is turned ON
Remedy 1. Check the conduction of the Fixing Thermal Switch 1/2
(TP1/2).
2. Check the drawer between the
Fixing Assembly and the host machine.
3. Check the connection between the
Main Driver PCB (PCB2)
and the Fixing Power Supply PCB
(PCB10).
4. Replace the Fixing Power Supply
Unit.
5. Replace the Main Driver PCB
(PCB2).
Description Detected OFF with 12V of the Fixing
Power Supply output after IH relay is turned ON.
E808 -0006 -05 Title ASIC
error
Remedy Replace the DC Controller PCB (PCB1).
Description ASIC error.
E808 -0007 -05 Title
Fixing Power Supply error
Remedy Check the connection between the
Main Driver PCB (PCB2) and the Fixing Power Supply PCB (PCB10). Replace the
Fixing Power Supply PCB with the one for the correct location (voltage).
Description Inlet voltage and the IH Power
Supply ID are not matched.
E808 -0008 -05 Title
Fixing Power Supply error
Remedy 1. Check the connection between the Main Driver PCB
(PCB2) and the Fixing Power Supply PCB (PCB10).
2. Check the connection between the Fixing
Power Supply PCB (PCB10) and the Heater Unit.
3. Replace the Fixing Assembly
(Fixing Roller and HeaterUnit).
4. Replace the Fixing Power Supply
PCB (PCB10).
5. Replace the Main Driver PCB
(PCB2).
Description Current fluctuation
error.
E808 -0009 -05 Title
Fixing Power Supply error
Remedy Replace the DC Controller PCB (PCB1).
Description Unable to clear the error flag at power-on.
E820 -0000 -05 Title
Developer Lower Cooling Fan error
Remedy 1. Check the connection of the Connector.
2. Replace the Developer Lower
Cooling Fan (FM30).
Description The Fan stop signal is detected for
5 seconds or longer and retry is failed 4 times in a row although the Developer
Lower Cooling Fan (FM30) is turned ON.
E820 -0001 -05 Title
Developer Upper Cooling Fan error
Remedy 1. Check the connection of the
Connector.
2. Replace the Developer Upper
Cooling Fan (FM31).
Description The Fan stop signal is detected for
5 seconds or longer and retry is failed 4 times in a row although the Developer
Upper Cooling Fan (FM31) is turned ON.
E820 -0002 -05 Title Duplex
Driver Cooling Fan error
Remedy 1. Check the connection of the Connector. 2. Replace the
Duplex Driver Cooling Fan (FM41).
Description The Fan stop signal is detected for
5 seconds or longer and retry is failed 4 times in a row although the Duplex
Driver Cooling Fan (FM41) is turned ON.
E824 -0000 -05 Title
Primary Charging Air Supply Fan error
Remedy 1. Check the connection of the
Connector.
2. Replace the Primary Charging Air
Supply Fan (FM2).
Description The Fan stop signal is detected for
5 seconds or longer and
retry is failed 4 times in a row
although the Primary Charging Air Supply Fan (FM2) is turned ON.
E840 -0001 -05 Title
Fixing Shutter Motor error
Remedy 1. Check the operation of the Fixing Shutter Gear
(overload, etc.).
2. Check the operation of the Fixing
Shutter Motor (M15) at the initialization operation of the Fixing Shutter.
3. Check the detection of the Fixing
Shutter HP Sensor (PS53)
(if the Sensor operates normally).
4. Check the drawer of the Fixing
Assembly and the host machine.
5. Replace the Fixing Assembly.
6. Replace the Main Driver PCB
(PCB2) (check the fuse (FU11)).
Description The Fixing Shutter HP Sensor (PS53)
failed the detection at
the Fixing Shutter operation.
E880 -0001 -00 Title
Controller Fan error
Remedy Connector disconnection, failure of
Fan.
Description Error in the Main Controller Cooling Fan (FM4) is detected.
E880 -0005 -00 Title
Controller Fan error
Remedy Connector disconnection, failure of Fan.
Description Error in the HDD Cooling Fan (FM)
is detected.
E905 -0001 -05 Title POD
Deck Air Assist Fan error
Remedy 1. Check connector disconnection/improper connection.
=>Disconnect and then connect the connector.Target connector: Deck Lite
Controller J04, J05 BoxDriver J51, J52, J57
2. Replace the Swing Motor (M3) and
the Air Assist Fan (FM1,FM2, FM3).
3. Replace the Deck Lite Controller
PCB.
4. Replace the BoxDriver PCB.
Description [POD Deck Lite] When the Air Assist
Swing Motor fails to return
to the HP although a specified period of time has passed
E905 -0002 -05 Title POD
Deck Air Assist Fan error
Remedy 1. Check connector
disconnection/improper connection. =>Disconnect and then connect the
connector.Target connector: Deck Lite Controller J30
2. Replace the Motor Cooling Fan
(FM4).
3. Replace the Deck Lite Controller
PCB.
Description [POD Deck Lite] When the Pickup
Motor Cooling Fan is not locked
E905 -0003 -05 Title POD
Deck Air Assist Fan error
Remedy 1. Check connector
disconnection/improper connection. => Disconnect and then connect the
connector.Target connector: Deck Lite Controller J30
2. Replace the Motor Cooling Fan
(FM4).
3. Replace the Deck Lite Controller
PCB.
Description [POD Deck Lite] When the Pickup
Motor Cooling Fan is not unlocked
E906 -0001 -05 Title POD
Deck Air Heater error
Remedy 1. Check connector
disconnection/improper connection. =>Disconnect and then connect the
connector.Target connector: Deck Lite Controller J03, J05BoxDriver J52, J54,
J58, J59
2. Replace the Air Heater.
3. Replace the Deck Lite Controller
PCB.
Description [POD Deck Lite] Air Heater high
temperature error When 120 deg C or higher temperature is detected for 1 second
consecutively
E906 -0002 -05 Title POD
Deck Air Heater error
Remedy 1. Check connector disconnection/improper connection.
=> Disconnect and then connect the connector.Target connector: Deck Lite
Controller J03, J05 BoxDriver J52, J54, J58, J59
2. Replace the Air Heater.
3. Replace the Deck Lite Controller
PCB.
Description [POD Deck Lite] Air Heater low
temperature error When the heater does not become Ready although a specified period of time has passed
E996 -xxxx -05 Title
Timeout error
Remedy Turn OFF and then ON the main power.