Remedy 1.
Check the connection of the Fixing Assembly. (Connection error of the Drawer,
connector disconnection, open circuit) -> Replace the Heater Assembly.
2. Check the connection between the Main
Driver PCB (PCB2) and the Fixing Power Supply PCB (PCB10) (connector disconnection,
open circuit, the caught cable).
3. Replace the Fixing Power Supply
PCB (PCB10).
4. Replace the Main Driver PCB
(PCB2).
5. Replace the DC Controller PCB
(PCB1).
Description Temperature of the Fixing Main Thermistor
(THM1) does not reach 70 degC although 35 seconds have passed after starting
the Fixing Roller temperature control.
E000 -0002 -05 Title
Fixing Assembly low temperature error
Remedy 1. Check the connection of the Fixing Assembly.
(Connection error of the Drawer, connector disconnection, open circuit)->
Replace the Heater Assembly.
2. Check the connection between the
Main Driver PCB (PCB2)
and the Fixing Power Supply PCB
(PCB10) (connector
disconnection, open circuit, the
caught cable).
3. Replace the Fixing Power Supply
PCB (PCB10).
4. Replace the Main Driver PCB
(PCB2).
5. Replace the DC Controller PCB
(PCB1).
Description Temperature of the Fixing Main Thermistor
(THM1) does not reach 10 degC although 35 seconds have passed after starting
the Fixing Roller temperature control.
E000 -0010 -05 Title
Fixing Assembly low temperature error
Remedy Clear the error.
Description Turning OFF and then ON the power
without clearing the error.
E002 -0001 -05 Title
Fixing Assembly temperature rise error
Remedy 1. Check the connection of the Fixing Main Thermistor (THM1).
-> Replace the Fixing Main Thermistor Unit.
2. Check the installation of the
Fixing Main Thermistor. ->Replace the Fixing Assembly.
3. Replace the Fixing Power Supply
PCB (PCB10).
4. Replace the Main Driver PCB
(PCB2).
5. Replace the DC Controller PCB
(PCB1).
6. Replace the Relay PCB (PCB5).
Description Temperature of the Fixing Main
Thermistor (THM1) does not reach 100 degC although 25 seconds have passed since
it reached above 70 degC after starting the Fixing
Roller temperature control. Temperature
of the Fixing Main Thermistor does not reach 130•
E002 -0010 -05 Title
Fixing Assembly temperature rise error
Remedy Clear the error.
Description Turning OFF and then ON
the power without clearing the error.
E003 -0000 -05 Title
Fixing Assembly temperature decrease error
Remedy 1. Check the connection of the
Fixing Main Thermistor (THM1). -> Replace the Fixing Main Thermistor Unit.
2. Check the installation of the
Fixing Main Thermistor. ->Replace the Fixing Assembly.
3. Replace the Fixing Power Supply
PCB (PCB10).
4. Replace the Main Driver PCB
(PCB2).
5. Replace the DC Controller PCB
(PCB1).
6. Replace the Relay PCB (PCB5).
Description The Fixing Main Thermistor (THM1) detects 70
degC or lower
for 2 seconds or longer although the
temperature reached
above 100 degC after starting the
Fixing Roller temperature control.
E003 -0010 -05 Title
Fixing Assembly temperature decrease error
Remedy Clear the error.
Description Turning OFF and then ON the power
without clearing the error.
E004 -0010 -05 Title
Fixing Power Supply error
Remedy Clear the error.
Description Turning OFF and then ON the power
without clearing the error.
E004 -0102 -05 Title
Fixing Power Supply error
Remedy Replace the Fixing Power Supply PCB
(PCB10). Replace the Main Driver PCB (PCB2).
Description Fixing current error
E004 -0205 -05 Title
Fixing Power Supply error
Remedy 1. Check the harness of the Fixing
Main Thermistor (THM1) in the Fixing Assembly.
2. Check the connection of the
harness of the Fixing Assembly on the host machine side.
3. Replace the Main Driver PCB
(PCB2).
Description Detect that the Fixing Main
Thermistor (THM1) is not connected.
E005 -0000 -05 Title
Fixing Cleaning Web absent error
Remedy 1. Replace the Fixing Cleaning Web.
2. Replace the Fixing Cleaning Web
Level Sensor (PS45).
3. Replace the DC Controller PCB
(PCB1).
After executing the measures, clear
the Fixing Cleaning
Web counter (COPIER > COUNTER
> MISC > FIXWEB).
Description After noticing the Fixing Cleaning Web absent,
the web was pulled out 2000 times.
E005 -0001 -05 Title Error
in Fixing Cleaning Web Drive Solenoid connection
Remedy 1. Check the connection of the
Connector.
2. Replace the Fixing Cleaning Web Drive
Solenoid (SL9).
Description Connection of the Fixing Cleaning
Web Drive Solenoid (SL9)
is not detected when the power is
turned ON.
E005 -0010 -05 Title
Fixing Cleaning Web error
Remedy Clear the error.
Description Turning OFF and then ON the power without
clearing the error
No comments: