E060 -0001 -05 Title
Primary Charging Shutter HP open error
Remedy 1. Check the position of the Primary
Charging Shutter and the Cleaning Pad.
1-A. In the case that the Primary Charging Shutter and the Cleaning
Pad fail to operate (stopped at HP at front side)
1-A-1. Check the connection of the Primary Charging Wire Cleaning
Motor (M6).
Motor side: J3017, J3060 (iR-ADV
8xxx)/J3160 (Iradv 6xxx) (relay), PCB side: J3177 (relay), J107
(Main Driver PCB (PCB2))
1-A-2. Replace the Primary Charging Wire Cleaning Motor (M6).
1-B. In the case that the Primary Charging Shutter and the
Cleaning Pad are stopped at rear
side (close operation position)
1-B-1. Check the connection of the Primary
Charging Shutter Sensor (PS94).
Sensor side: J2029, J3089 (relay),
PCB side: J3088 (relay), J114 (Main Driver PCB (PCB2))
1-B-2. Replace the Primary Charging Shutter Sensor (PS94).
1-C. In the case that the Primary Charging Shutter and the Cleaning
Pad are stopped along the way
1-C-1. Check the loosening of screw on the
Slider Pin and abrasion of the pin. Tighten the screw or replace the Slider
Pin.
1-C-2. Replace the Primary Charging Assembly.
1-D. In the case that the Primary Charging Shutter stops at front
side and the Cleaning Pad moves to rear side
1-D-1. Check if the Shutter Mounting Plate is deformed. If so,
replace the Shutter Unit.
1-D-2. Check the loosening of screw on the
Slider Pin and abrasion of the pin. Tighten the screw or replace the Slider
Pin.
1-D-3. Replace the Primary Charging Assembly.
2. Replace the Main Driver PCB
(PCB2).
3. Replace the DC Controller PCB
(PCB1).
Description The Primary Charging Shutter Sensor
(PS94) detects that the shutter is opened although it is moved to the close
position.
E060 -0002 -05 Title
Primary Charging Shutter HP close error
Remedy 1. Check the position of the Primary
Charging Shutter and the Cleaning Pad.
1-A. In the case that the Primary Charging Shutter and the
Cleaning Pad fail to operate
(stopped at HP at front side)
1-A-1. Check the connection of the Primary
Charging Wire Cleaning Motor (M6). Motor side: J3017, J3060 (iR-ADV 8xxx)/J3160
(iRADV 6xxx) (relay), PCB side: J3177 (relay), J107 (Main Driver PCB (PCB2))
1-A-2. Replace the Primary Charging Wire Cleaning Motor (M6).
1-B. In the case that the Primary Charging Shutter and the Cleaning
Pad are stopped at rear side (close operation position)
1-B-1. Check the connection of the Primary Charging Shutter
Sensor (PS94). Sensor side: J2029, J3089 (relay), PCB side: J3088 (relay), J114
(Main Driver PCB (PCB2))
1-B-2. Replace the Primary Charging Shutter Sensor (PS94).
1-C. In the case that the Primary Charging Shutter and the
Cleaning Pad are stopped along the
way
1-C-1. Check the loosening of screw on the Slider Pin and abrasion
of the pin. Tighten the screw or replace the Slider Pin.
1-C-2. Replace the Primary Charging Assembly.
2. Replace the Main Driver PCB
(PCB2).
3. Replace the DC Controller PCB
(PCB1).
Description The Primary Charging Shutter Sensor
(PS94) detects that the shutter is closed although it is moved to the open position.\
E061 -0001 -05 Title
Potential control error (VL)
Remedy 1. Check the connection of the
Pre-exposure LED (connector connection, open circuit, the caught cable).
2. Check the installation of the
Primary Charging Assembly
(connector connection, open circuit,
the caught cable).
3.
Check the fixation state of the Drum and the Drum Shaft.
(Check
if the drum fixation cylinder is properly installed.)
4. Check if the Dustproof Glass is
soiled. If necessary, clean it.
5. Check the installation of the
Laser Scanner Unit (connector
connection, open circuit, the caught
cable).
6. Check the installation of the
Primary Charging High Voltage PCB (PCB11), and its connection (connector
connection, open circuit, the caught cable).
7. Check the installation of the
Potential Sensor (connector connection, open circuit, the caught cable).
8. Check the installation of the
Drum Motor (M1), and its connection (connector connection, open circuit, the
caught cable).
9. Replace the parts. Primary
Charging Assembly
Laser Scanner ,Unit Potential Sensor,
Primary Charging High Voltage PCB (PCB11)
Drum Motor (M1), Main Driver PCB
(PCB2),DC Controller PCB (PCB1)
•••••••
Description The measured value in the dark area
(VL) differs +/-30V or
higher than the target potential at
potential control.
MEMO: If the difference is somewhere between +/-10V
and less than 30V, alarm is indicated.
E061 -0101 -05 Title
Potential control error (VD)
Remedy 1. Check the connection of the Pre-exposure LED
(connector
connection, open circuit, the caught
cable).
2. If the current value of the
Primary Charging Roller (COPIER> DISPLAY > DPOT > PRIM-C) is 1550
micro A or higher,execute 2-1 to 3.
2-1. Increase the grid voltage of
the Primary Charging Assembly by 100V (COPIER > ADJUST > HV-PRI
> PRI-GRID).
2-2. Execute the potential control
(COPIER > FUNCTION > DPC > DPC).
2-3. Turn OFF and then ON the power.
3. Check the installation of the
Primary Charging Assembly
(connector connection, open circuit,
the caught cable).
4. Check the installation of the
Primary Charging High Voltage PCB (PCB11), and its connection (connector
connection, open circuit, the caught cable).
5. Check the installation of the
Drum Motor (M1), and its connection (connector connection, open circuit, the
caught cable).
6. Replace the parts.
Primary Charging Assembly,Primary
Charging High Voltage PCB,Drum Motor (M1),Main Driver PCB (PCB2),DC Controller
PCB (PCB1)•••••
Description Potential in the dark area did not
fall within the range (target value +/-10V) although retry was executed 8 times
at VD potential control.
E064 -00FF -05 Title High
voltage setting error
Remedy 1. Turn OFF and then ON the main power. 2. Replace the
DCON PCB.
Description With the state in which the
developing AC is output, 600V or higher developing DC output was detected. (Basically,
this error is not detected. However, to detect that the image formation-related
backup data is corrupted or to protect the hardware in case of 600V or higher
developing DC output, this is to be an error.)
E065 -0001 -05 Title
Primary charging/grid high voltage output leak error
Remedy 1. Check the connection between the Main Driver PCB
(PCB2) and the High Voltage Unit.
Main Driver side: J111, High Voltage
Unit side: J3097
2. Check the connection between the
Relay PCB (PCB5) and the High Voltage Unit.
Relay side: J519, High Voltage Unit
side: J3099
3. Replace the Primary Charging
Assembly.
4. Check the connection inside of
the High Voltage Unit.
High Voltage Unit Relay (J3097) and
Primary Charging,High Voltage PCB (PCB11) (J3501),High Voltage Unit relay
(J3099) and Pre-transfer Charging,PCB (PCB26) (J3545, J3500)
5. Replace the Main Driver PCB
(PCB2).
6. Replace the Primary Grid High
Voltage Connector (FM4-1006).
Description The leak detection signal was
detected 5 times in a row for every 20 msec
E066 -0001 -05 Title
Pre-transfer Charging Shutter HP open error
Remedy 1. Check the position of the
Pre-transfer Charging Shutter.
1-A. In the case that the Pre-transfer Charging Shutter fails
to operate (stopped at HP at front side)
Check the connection of the
Pre-transfer Charging Wire Cleaning Motor (M7). Sensor side: J3108, J3089
(relay), PCB side: J3088 (relay), J114 (Main Driver PCB (PCB2))
1-B. In the case that the Pre-transfer Charging Shutter is stopped
at rear side (close operation position)
1-B-1. Check that the Primary Fan Duct is
closed. Close the Primary Fan Duct.
1-B-2. Check movement of the pin to push
the Pre-transfer Charging Shutter Sensor (PS95). Replace the Pin.
1-B-3. Check movement of the flag on the Pre-transfer Charging
Shutter Sensor (PS95). Replace the flag/spring.
1-B-4. Check the connection of the Pre-transfer Charging Shutter
Sensor (PS95). Sensor side: J2114, J3215 (relay), J3067 (relay) PCB side: J3066
(relay), J130 (Main Driver PCB (PCB2))
1-C. In the case that the Pre-transfer Charging Shutter is stopped
along the way
1-C-1. Check abrasion of the Slider Pin. Replace the Slider Pin.
1-C-2. Replace the Pre-transfer Charging Assembly.
2. Replace the DC Controller PCB (PCB1).
Description The Pre-transfer Charging Shutter
Sensor (PS95) detects that the shutter is opened although it is moved to the
close position
E066 -0002 -05 Title
Pre-transfer Charging Shutter HP close error
Remedy 1. Check the position of the
Pre-transfer Charging Shutter.
1-A. In the case that the Pre-transfer Charging Shutter fails
to operate (stopped at HP at front side)
Check the connection of the
Pre-transfer Charging Wire Cleaning Motor (M7). Sensor side: J3108, J3089
(relay), PCB side: J3088 (relay), J114 (Main Driver PCB (PCB2))
1-B. In the case that the Pre-transfer Charging Shutter is stopped
at rear side (close operation position)
1-B-1. Check that the Primary Fan Duct is
closed. Close the Primary Fan Duct.
1-B-2. Check movement of the pin to push the Pre-transfer Charging
Shutter Sensor (PS95). Replace the Pin.
1-B-3. Check movement of the flag on the Pre-transfer Charging
Shutter Sensor (PS95). Replace the flag/ spring.
1-B-4. Check the connection of the
Pre-transfer Charging Shutter Sensor (PS95). Sensor side: J2114, J3215 (relay),
J3067 (relay) PCB side: J3066 (relay), J130 (Main Driver PCB (PCB2))
1-C. In the case that the Pre-transfer Charging Shutter is stopped
along the way
1-C-1. Check abrasion of the Slider Pin. Replace the Slider Pin.
1-C-2. Replace the Pre-transfer Charging Assembly.
2. Replace the DC Controller PCB (PCB1).
Description The Pre-transfer Charging Shutter
Sensor (PS95) detects that the shutter is closed although it is moved to the
open position.
E067 -0001 -05 Title
Developing high voltage output leak error
Remedy 1. Check the connection between the
Main Driver PCB (PCB2) and the High Voltage Unit.
Main Driver side: J112, High Voltage
Unit side: J3098
2. Check the connection between the Relay PCB (PCB5) and the
High Voltage Unit.
Relay side: J519, High Voltage Unit
side: J3099
3. Replace the Developing Assembly.
4. Check the connection point of the Developing Assembly. If
it is soiled, clean it.
5. Check the connection inside of the High Voltage Unit. Check
the connection of the High Voltage Unit Relay (J3097) and the Developing High
Voltage PCB (J3511). High Voltage Unit Relay (J3099) and Pre-transfer Charging PCB
(J3545, J3500, J3510)
6. Replace the Main Driver PCB (PCB2).
Description The leak detection
signal was detected 5 times in a row for every 20 msec.
E068 -0001 -05 Title
Pre-transfer charging high voltage output leak error
Remedy 1. Check the connection between the
Main Driver PCB (PCB2) and the High Voltage Unit.
Main Driver side: J112, High Voltage
Unit side: J3098
2. Check the connection between the
Relay PCB (PCB5) and the High Voltage Unit.
Relay side: J519, High Voltage Unit
side: J3099
3. Replace the Pre-transfer Charging
Assembly.
4. Check the connection inside of
the High Voltage Unit. Check the connection of the High Voltage Unit Relay (J3098)
and the Transfer High Voltage PCB (J3544).Check the connection of the High
Voltage Unit Relay (J3099) and the Pre-transfer Charging PCB (J3545, J3500)
5. Replace the Main Driver PCB
(PCB2).
6. Replace the Pre-transfer High
Voltage Connector (FM4-1007).
7. Replace the Pre-transfer
Transformer (Post Charging
Trance) of the High Voltage Unit.
Description The leak detection signal was
detected 5 times in a row for every 20 mse
E069 -0001 -05 Title
Transfer high voltage output leak error
Remedy 1. Check the connection between the
Duplex Driver PCB (PCB4) and the High Voltage Unit.
Check the connection at Duplex
Driver side (J343) and the Transfer High Voltage side (J3066).
Check the connection at Duplex
Driver side (J311) and the Transfer High Voltage side (J3061). (In addition,
check that 24V is output.)
2. Check the connection of the
Transfer High Voltage PCB (J3306).
3. Replace the ETB Unit.
4. Replace the Duplex Driver PCB
(PCB4).
Description The leak detection signal was
detected 5 times in a row for every 20 msec.