Errorcode E001 To E005 for Canon ImageRunner 6275 6265 6255
.






E000-0001 -05 Title Fixing Assembly low temperature error.





Detection
description
Temperature of the Fixing Main Thermistor (THM1) does


not reach 70 degC although 20 seconds have passed after


starting the Fixing Roller temperature control.


Remedy 1. Check the connection of the Fixing Assembly. (Connection


error of the Drawer, connector disconnection, open circuit)-> Replace the Heater Assembly.


2. Check the connection between the Main Driver PCB (PCB2)


and the Fixing Power Supply PCB (PCB10) (connector


disconnection, open circuit, the caught cable).


3. Replace the Fixing Power Supply PCB (PCB10).


4. Replace the Main Driver PCB (PCB2).


5. Replace the DC Controller PCB (PCB1).


E000-0002 -05 Title Fixing Assembly low temperature error.




Detection
description
Temperature of the Fixing Main Thermistor (THM1) does


not reach 10 degC although 20 seconds have passed after


starting the Fixing Roller temperature control.


Remedy 1. Check the connection of the Fixing Assembly. (Connection


error of the Drawer, connector disconnection, open circuit)-> Replace the Heater Assembly.


2. Check the connection between the Main Driver PCB (PCB2)


and the Fixing Power Supply PCB (PCB10) (connectordisconnection, open circuit, the caught cable).


3. Replace the Fixing Power Supply PCB (PCB10).


4. Replace the Main Driver PCB (PCB2).


5. Replace the DC Controller PCB (PCB1).


E000-0010 -05 Title Fixing Assembly low temperature errorDetection




Detection
description
Turning OFF and then ON the power without clearing the error.


Remedy Clear the error.






E001-0002 -05 Title Fixing Assembly high temperature error (software detection) .






Detection description• The Fixing Main Thermistor (THM1) detects 230 degC orhigher.


• The Fixing Sub Thermistor 1 (THM2)/Fixing Sub Thermistor


2 (THM3) detects 230 degC or higher for 2 consecutiveseconds.


Remedy 1. Check if the cable of the Thermistor is caught. -> Replace


the Thermistors. -> Replace the Fixing Upper Unit.


2. IH control error. -> Replace the Fixing Power Supply PCB


(PCB10), the DC Controller PCB (PCB1), or the Main DriverPCB (PCB2).


E001-0003 -05 Title Fixing Assembly high temperature error (hardware detection) .




Detection
description
• The Fixing Main Thermistor (THM1) detects hardwareoverheating.


• The Fixing Sub Thermistor 1 (THM2)/Fixing Sub Thermistor


2 (THM3) detects hardware overheating.


Remedy 1. Check if the cable of the Thermistor is caught. -> Replace


the Thermistors. -> Replace the Fixing Upper Unit.


2. Replace the Main Driver PCB (PCB2).


3. Replace the DC Controller PCB (PCB1).


E001-0004 -05 Title Fixing Assembly high temperature error (hardware detection) .




Detection
description
Abnormal temperature difference among the Thermistors wasdetected.


Remedy 1. Check if the cable of the Thermistor is caught or is open


circuit. -> Replace the Thermistors. -> Replace the FixingUpper Unit.


2. Replace the Main Driver PCB (PCB2).


3. Replace the DC Controller PCB (PCB1).


4. Check if the Fixing Shutter operates. -> Replace the FixingAssembly.


E001-0010 -05 Title Fixing Assembly high temperature error.




Detection
description
Turning OFF and then ON the power without clearing theerror.


Remedy Clear the error.






E002-0001 -05 Title Fixing Assembly temperature rise error



Detection description


• Temperature of the Fixing Main Thermistor (THM1) does not


reach 100 degC although 12 seconds have passed since


it reached above 70 degC after starting the Fixing Roller temperature control.


• Temperature of the Fixing Main Thermistor does not reach


130 degC although 12 seconds have passed since it


reached above 100 degC after starting the Fixing Roller temperature control.


• Temperature of the Fixing Main Thermistor does not reach


150 degC although 15 seconds have passed since it


reached above 130 degC after starting the Fixing Roller temperature control.


Remedy 1. Check the connection of the Fixing Main Thermistor (THM1).


-> Replace the Fixing Main Thermistor Unit.


2. Check the installation of the Fixing Main Thermistor. ->


Replace the Fixing Upper Unit.


3. Replace the Fixing Power Supply PCB (PCB10).


4. Replace the Main Driver PCB (PCB2).


5. Replace the DC Controller PCB (PCB1).


6. Replace the Relay PCB (PCB5).


E002-0010 -05 Title Fixing Assembly temperature rise error


Detection description


Turning OFF and then ON the power without clearing theerror.


Remedy Clear the error.







E003-0000 -05 Title Fixing Assembly temperature decrease error


Detection description


The Fixing Main Thermistor (THM1) detects 70 degC or lower


for 2 seconds or longer although the temperature reached


above 100 degC after starting the Fixing Roller temperature control.


Remedy 1. Check the connection of the Fixing Main Thermistor (THM1).


-> Replace the Fixing Main Thermistor Unit.


2. Check the installation of the Fixing Main Thermistor. ->


Replace the Fixing Upper Unit.


3. Replace the Fixing Power Supply PCB (PCB10).


4. Replace the Main Driver PCB (PCB2).


5. Replace the DC Controller PCB (PCB1).


6. Replace the Relay PCB (PCB5).


E003-0010 -05 Title Fixing Assembly temperature decrease error


Detection description


Turning OFF and then ON the power without clearing the error.


Remedy Clear the error.


E004-0010 -05 Title Fixing Power Supply error


Detection description


Turning OFF and then ON the power without clearing the error.


Remedy Clear the error.




E004-0205 -05 Title Fixing Power Supply error


Detection description


Detect that the Fixing Main Thermistor Unit is not connected.


Remedy 1. Check the harness of the Fixing Main Thermistor (THM1) in


the Fixing Assembly.


2. Check the connection of the harness of the Fixing Assembly


on the host machine side.


3. Replace the Main Driver PCB (PCB2).


E005-0000 -05 Title Fixing Cleaning Web absent error


Detection description


After noticing the Fixing Cleaning Web absent, the web was pulled out 2000 times.


Remedy 1. Replace the Fixing Cleaning Web.


2. Replace the Fixing Cleaning Web Level Sensor (PS45).


3. Replace the DC Controller PCB (PCB1).


After executing the measures, clear the Fixing Cleaning Web


counter (COPIER> COUNTER> MISC> FIXWEB).


E005-0001 -05 Title Error in Fixing Cleaning Web Drive Solenoid connection


Detection description


Connection of the Fixing Cleaning Web Drive Solenoid (SL9)


is not detected when the power is turned ON.


Remedy 1. Check the Connector of the Fixing Cleaning Web DriveSolenoid.


2. Check the output of the DC Power Supply PCB (24V) (PCB31).


Using a tester, check whether 24V is output from 3PIN


through 6PIN of J513 on the Relay PCB. In case of error,


replace the DC Power Supply PCB (24V) (PCB31) (on the right).


3. Replace the Fixing Cleaning Web Drive Solenoid (SL9).


E005-0010 -05 Title Fixing Cleaning Web error


Detection description Turning OFF and then ON the power without clearing the error.


Remedy Clear the error.