Detection description The receiving-light intensity failed to be within the threshold
although
the emitting-light intensity is adjusted to be within the threshold when adjusting the
Sensor.
Remedy 1. Connector of the Slowing Timing Sensor (S30)
is disconnected.
2.
Slowing Timing Sensor (S30) is faulty.
E562 -8002 -05 Title Error in Disengagement Timing Sensor (Paper Folding Unit-H1)
Detection description The receiving-light intensity failed to be within the threshold
although
the emitting-light intensity is adjusted to be within the threshold when adjusting
the Sensor.
Remedy 1. Connector of the Disengagement Timing Sensor
(S31) is disconnected.
2. Disengagement Timing
Sensor (S31) is faulty.
E562 -8003 -05 Title Error in Folding Position Accuracy Sensor (Paper
Folding Unit-H1)
Detection description The receiving-light intensity failed to be within the threshold
although
the emitting-light intensity is adjusted to be within the threshold when adjusting
the Sensor.
Remedy 1. Connector of the Folding Position Accuracy
Sensor (S32) is disconnected.
2.
Folding Position Accuracy Sensor (S32) is faulty.
E562 -8004 -05 Title Error in the Upper Stopper HP Sensor (Paper Folding
Unit-H1)
Detection description The receiving-light intensity failed to be within the threshold
although
the emitting-light intensity is adjusted to be within the threshold when adjusting
the Sensor.
Remedy 1. Connector of the Upper Stopper HP Sensor (S23)
is disconnected.
2.
Upper Stopper HP Sensor (S23) is faulty.
E566 -8001 -05 Title Error in side registration detection
Detection description Side registration detection unit HP sensor does not come ON
within
5 sec after the side registration detection unit shift motor starts operation.
Remedy 1. Connector check of side registration detection
unit shift motor and side registration detection unit HP sensor
2.
Replacement of side registration detection unit shift motor and side registration
detection unit HP sensor
3.
Replacement of finisher controller PCB
E566 -8002 -05 Title Error in side registration detection
Detection description Side registration detection unit HP sensor does not go OFF
within
5 sec after the side registration detection unit shift motor starts operation.
Remedy 1. Connector check of side registration
detection unit shift motor and side registration detection unit HP
sensor
2.
Replacement of side registration detection unit shift motor and side registration
detection unit HP sensor
3.
Replacement of finisher controller PCB
E567 -8001 -05 Title Error in shift roller operation
Detection description Shift roller unit HP sensor does not come ON within 5 sec after
the
side registration shift motor starts operation.
Remedy 1. Connector check of side registration shift
motor and shift roller unit HP sensor
2.
Replacement of side registration shift motor and shift roller unit HP sensor
3. Replacement of
finisher controller PCB
E567 -8002 -05 Title Error in shift roller operation
Detection description Shift roller unit HP sensor does not go OFF within 5 sec after the side registration shift motor starts
operation.
Remedy 1. Connector check of side registration shift
motor and shift roller unit HP sensor
2.
Replacement of side registration shift motor and shift roller unit HP sensor
3.
Replacement of finisher controller PCB
E568 -8001 -05 Title a. Error in feed roller disengage operation
(Finisher-Q1)
b. Error in the Feed Roller Disengage/Buffer Flapper Motor (Finisher-N1)
Detection description
a.
Feed roller HP sensor does not come ON within 5 sec after the feed roller disengage
motor starts operation.
b.
The disengage roller does not come off the Feed Roller Separation HP Sensor when the Feed Roller
Disengage/ Buffer Flapper Motor has been driven for 3 seconds.
Remedy a-1. Connector check of feed roller disengage
motor and feed
roller
HP sensor
a-2.
Replacement of feed roller disengage motor and feed roller HP sensor
a-3.
Replacement of finisher controller PCB
b-1.
The connector of the Feed Roller Separation HP Sensor (S111) or the Feed Roller Disengage/Buffer
Flapper Motor (M119) are disconnected.
b-2.
The wiring of the Feed Roller Separation HP Sensor (S111) or the Feed Roller
Disengage/Buffer Flapper Motor (M119) are faulty.
b-3.
The Feed Roller Separation HP Sensor (S111) is faulty.
b-4.
The Feed Roller Disengage/Buffer Flapper Motor (M119) is faulty.
b-5. The Finisher
Controller PCB is faulty.
E568 -8002 -05 Title a. Error in feed roller disengage operation
(Finisher-Q1)
b. Error in the Feed Roller Disengage/Buffer Flapper Motor (Finisher-N1)
Detection description a. Feed roller HP sensor does not go OFF within 5 sec after
the
feed roller disengage motor starts operation.
b.
The Feed Roller Separation HP Sensor does not detect the
disengage
roller when the Feed Roller Disengage/Buffer Flapper Motor has been driven for 3 seconds.
Remedy a-1. Connector check of feed roller disengage
motor and feed roller HP sensor
a-2.
Replacement of feed roller disengage motor and feed roller HP sensor
a-3.
Replacement of finisher controller PCB
b-1.
The connector of the Feed Roller Separation HP Sensor (S111) or the Feed Roller Disengage/Buffer
Flapper Motor (M119) are disconnected.
b-2.
The wiring of the Feed Roller Separation HP Sensor (S111) or the Feed Roller
Disengage/Buffer Flapper Motor (M119) are faulty.
b-3.
The Feed Roller Separation HP Sensor (S111) is faulty.
b-4.
The Feed Roller Disengage/Buffer Flapper Motor (M119) is faulty.
b-5.
The Finisher Controller PCB is faulty.
E568 -8003 -05 Title Error in the Feed Roller Disengage/Buffer Flapper
Motor (Finisher-N1)
Detection description The buffer flapper does not come off the Buffer Flapper HP
Sensor
when the Feed Roller Disengage/Buffer Flapper Motor has been driven for 3 seconds.
Remedy 1. The connector of the Buffer Flapper HP Sensor
(S142) or the Feed Roller Disengage/Buffer Flapper Motor (M119) are disconnected.
2.
The wiring of the Buffer Flapper HP Sensor (S142) or the Feed Roller
Disengage/Buffer Flapper Motor (M119) are faulty.
3.
The Buffer Flapper HP Sensor (S142) is faulty.
4.
The Feed Roller Disengage/Buffer Flapper Motor (M119) is faulty.
5. The Finisher
Controller PCB is faulty.
E568 -8004 -05 Title Error in the Feed Roller Disengage/Buffer Flapper
Motor (Finisher-N1)
Detection description The Buffer Flapper HP Sensor does not detect the buffer
flapper
when the Feed Roller Disengage/Buffer Flapper Motor has been driven for 3 seconds.
Remedy 1. The connector of the Buffer Flapper HP Sensor
(S142) or
the
Feed Roller Disengage/Buffer Flapper Motor (M119) are disconnected.
2.
The wiring of the Buffer Flapper HP Sensor (S142) or the Feed Roller
Disengage/Buffer Flapper Motor (M119) are faulty.
3.
The Buffer Flapper HP Sensor (S142) is faulty.
4.
The Feed Roller Disengage/Buffer Flapper Motor (M119) is faulty.
5.
The Finisher Controller PCB is faulty.
E569 -8001 -05 Title Upper Stopper Motor of Paper Folding Unit failed to
go through HP (Paper Folding Unit-H1)
Detection description The Upper Stopper HP Sensor failed to be OFF despite the
drive
of specified pulse in the case that the Upper Stopper Motor started to be driven while the Upper
Stopper HP Sensor was ON.
Remedy 1. Connector of the Upper Stopper Motor (M8) is
disconnected.
2.
Upper Stopper Motor (M8) is faulty.
3. Connector
of the Upper Stopper HP Sensor (S23) is disconnected.
4.
Upper Stopper HP Sensor (S23) is faulty.
E569 -8002 -05 Title Upper Stopper Motor of Paper Folding Unit failed to
return to HP (Paper Folding Unit-H1)
Detection description The Upper Stopper HP Sensor failed to be ON despite the
drive
of specified pulse in the case that the Upper Stopper Motor started to be driven while the Upper
Stopper HP Sensor was OFF.
Remedy 1. Connector of the Upper Stopper Motor (M8) is
disconnected.
2.
Upper Stopper Motor (M8) is faulty.
3.
Connector of the Upper Stopper HP Sensor (S23) is disconnected.
4. Upper Stopper HP
Sensor (S23) is faulty.
E569 -8003 -05 Title Upper Stopper Motor of Paper Folding Unit failed to
go through
HP (Paper Folding Unit-H1)
Detection description The Upper Stopper HP Sensor failed to be OFF despite the
drive
of specified pulse in the case that the Upper Stopper Motor started to be driven while the Upper
Stopper HP Sensor was ON.
Remedy 1. Connector of the Upper Stopper Motor (M8) is
disconnected.
2.
Upper Stopper Motor (M8) is faulty.
3.
Connector of the Upper Stopper HP Sensor (S23) is disconnected.
4.
Upper Stopper HP Sensor (S23) is faulty.
E569 -8004 -05 Title Upper Stopper Motor of Paper Folding Unit failed to
return to
HP (Paper Folding Unit-H1)
Detection description The Upper Stopper HP Sensor failed to be ON despite the
drive
of specified pulse in the case that the Upper Stopper Motor started to be driven while the Upper
Stopper HP Sensor was OFF.
Remedy 1. Connector of the Upper Stopper Motor (M8) is
disconnected.
2.
Upper Stopper Motor (M8) is faulty.
3.
Connector of the Upper Stopper HP Sensor (S23) is disconnected.
4.
Upper Stopper HP Sensor (S23) is faulty.
E56A -8001 -05 Title C-fold Stopper Motor of Paper Folding Unit failed to
go through
HP (Paper Folding Unit-H1)
Detection description The C-fold Stopper Motor HP Sensor failed to be OFF despite
the
drive of specified pulse in the case that the C-fold Stopper
Motor
started to be driven while the C-fold Stopper Motor HP Sensor was ON.
Remedy 1. Connector of the C-fold Stopper Motor (M9) is
disconnected.
2.
C-fold Stopper Motor (M9) is faulty.
3.
Connector of the C-fold Stopper HP Sensor (S24) is disconnected.
4.
C-fold Stopper HP Sensor (S24) is faulty.
E56A -8002 -05 Title C-fold Stopper Motor of Paper Folding Unit failed to
return to
HP (Paper Folding Unit-H1)
Detection description The C-fold Stopper Motor HP Sensor failed to be ON despite
the
drive of specified pulse in the case that the C-fold Stopper Motor started to be
driven while the C-fold Stopper Motor HP Sensor was OFF.
Remedy 1. Connector of the C-fold Stopper Motor (M9) is
disconnected.
2.
C-fold Stopper Motor (M9) is faulty.
3.
Connector of the C-fold Stopper HP Sensor (S24) is disconnected.
4. C-fold Stopper HP
Sensor (S24) is faulty.
E56B -8001 -05 Title Folding Tray Motor of Paper Folding Unit failed to go
through
HP (Paper Folding Unit-H1)
Detection description The Folding Tray HP Sensor failed to be OFF despite the
drive
of specified pulse in the case that the Folding Tray Motor started to be driven
while the Folding Tray HP Sensor was ON.
Remedy 1. Connector of the Folding Tray Motor (M7) is
disconnected.
2.
Folding Tray Motor (M7) is faulty.
3.
Connector of the Folding Tray HP Sensor (S28) is disconnected.
4.
Folding Tray HP Sensor (S28) is faulty.
E56B -8002 -05 Title Folding Tray Motor of Paper Folding Unit failed to
return to HP
(Paper Folding Unit-H1)
Detection descriptionThe Folding Tray HP Sensor failed to be ON
despite the drive
of
specified pulse in the case that the Folding Tray Motor started to be driven while the Folding Tray HP
Sensor was OFF.
Remedy 1. Connector of the Folding Tray Motor (M7) is
disconnected.
2.
Folding Tray Motor (M7) is faulty.
3.
Connector of the Folding Tray HP Sensor (S28) is disconnected.
4.
Folding Tray HP Sensor (S28) is faulty.
E56D -8001 -05 Title Error in the Stacking Tray Paper Retainer Motor
(Finisher-N1)
Detection description The stacking tray paper retainer does not come off the Stacking Tray Paper Retainer HP Sensor when the
Stacking
Tray
Paper Retainer Motor has been driven for 3 seconds.
Remedy 1. The connector of the Stacking Tray Paper
Retainer HP Sensor (S114) or the Stacking Tray Paper Retainer Motor (M114) are disconnected.
2.
The wiring of the Stacking Tray Paper Retainer HP Sensor (S114) or the Stacking
Tray Paper Retainer Motor (M114) are faulty.
3.
The Stacking Tray Paper Retainer HP Sensor (S114) is faulty.
4.
The Stacking Tray Paper Retainer Motor (M114) is faulty.
5. The Finisher
Controller PCB is faulty.
E56D
-8002 -05 Title Error in the Stacking Tray Paper Retainer Motor (Finisher-N1)
Detection description The Stacking Tray Paper Retainer HP Sensor does not detect
the
stacking tray paper retainer when the Stacking Tray Paper Retainer Motor has been
driven for 3 seconds.
Remedy 1. The connector of the Stacking Tray Paper
Retainer HP Sensor (S114) or the Stacking Tray Paper Retainer Motor (M114) are disconnected.
2.
The wiring of the Stacking Tray Paper Retainer HP Sensor (S114) or the Stacking Tray
Paper Retainer Motor (M114) are faulty.
3.
The Stacking Tray Paper Retainer HP Sensor (S114) is faulty.
4.
The Stacking Tray Paper Retainer Motor (M114) is faulty.
5.
The Finisher Controller PCB is faulty.
E56E -8001 -05 Title Lead-edge Retaining Guide Motor of Paper Folding Unit
failed
to go through HP (Paper Folding Unit-H1)
Detection description The Lead-edge Retaining Guide HP Sensor failed to be OFF
despite
the drive of specified pulse in the case that the Leadedge Retaining Guide Motor
started to be driven while the Lead-edge Retaining Guide HP Sensor was ON.
Remedy 1. Connector of the Lead-edge Retaining Guide
Motor (M10) is disconnected.
2.
Lead-edge Retaining Guide Motor (M10) is faulty.
3.
Connector of the Lead-edge Retaining Guide HP Sensor (S25) is disconnected.
4.
Lead-edge Retaining Guide HP Sensor (S25) is faulty.
E56E -8002 -05 Title Lead-edge Retaining Guide Motor of Paper Folding Unit
failed
to return to HP (Paper Folding Unit-H1)
Detection description The Lead-edge Retaining Guide HP Sensor failed to be ON
despite
the drive of specified pulse in the case that the Leadedge Retaining Guide Motor
started to be driven while the Lead-edge Retaining Guide HP Sensor was OFF.
Remedy 1. Connector of the Lead-edge Retaining Guide
Motor (M10) is disconnected.
2.
Lead-edge Retaining Guide Motor (M10) is faulty.
3.
Connector of the Lead-edge Retaining Guide HP Sensor (S25) is disconnected.
4.
Lead-edge Retaining Guide HP Sensor (S25) is faulty.
E56F -8001 -05 Title Error in inlet roller disengage operation
Detection description Inlet roller HP sensor does not come ON within 5 sec after the
inlet
roller disengage motor starts operation.
Remedy 1. Connector check of inlet roller disengage
motor and inlet roller HP sensor
2.
Replacement of inlet roller disengage motor and inlet roller HP sensor
3. Replacement of
finisher controller PCB
E56F -8002 -05 Title Error in inlet roller disengage operation
Detection description Inlet roller HP sensor does not go OFF within 5 sec after the
inlet
roller disengage motor starts operation.
Remedy 1. Connector check of inlet roller disengage
motor and inlet roller HP sensor
2.
Replacement of inlet roller disengage motor and inlet roller HP sensor
3.
Replacement of finisher controller PCB