E100 There is a BD error.
0001 A check is made of VLOCK at intervals of 100 msec while the laser is on.
An error
will be identified if it is not
detected 10 times in sequence.
- Replace the laser scanner unit. -
Replace the DC controller PCB.
E110 There is a polygon motor
error.
0001 - Although the polygon motor has been turned on, VLOCK is not detected at
all within 76.5 sec.
- At time of a shift from full-speed
to halfspeed control, VLOCK is not detected at all for 7.5 sec.
- At time of half-speed control, a
check is made of VLOCK at intervals of 100 msec.
An error will be identified if it is
not detected 10 times continuously.
- Replace the laser scanner unit. - Replace the DC controller PCB.
E121 There is a controller
cooling fan error.
0001 Even though the controller cooling fan has been turned on, the controller
cooling fan
stop signal has been detected for 5
sec or more.
- Check the connector for any fault
in connection. - Replace the fan.
E196 The EEPROM is faulty.
1abb There is a mismatch between the data that has been written in EEPROM and
the data
that has been read. (a: chip No. 0
through 5; bb: chip faulty address)
- Initialize the RAM. - Replace the
EEPROM. - Replace the DC controller PCB.
2abb The ID in EEPROM that has been read and the ID in ROM are compared. An
error
will be identified if they do not
match. (a: chip No. 0 through 5; bb: chip faulty address)
3abb When the main power is turned on, the ID in EEPROM and the ID in ROM are compared.
An error will be identified if they do not match. (a: chip No. 0 through 5; bb:
chip faulty address)
- Check the position and condition
of the EEPROM.
- Initialize the RAM. - Replace the
EEPROM. - Replace the DC controller PCB.
E202 There is a scanner HP
error.
0001 An error has occurred when the sensor was moved to home position. The
scanner HP sensor is faulty; the scanner motor is faulty; the reader controller
PCB is faulty.
- Check the connector for any fault
in connection. - Replace the scanner HP
sensor.
- Replace the scanner motor. -
Replace the reader controller PCB.
0002 An error has occurred when the sensor was moved from home position.
The scanner HP sensor is faulty; the
scanner motor is faulty; the reader controller
PCB is faulty.
E225 The intensity of light
is inadequate.
0001 At time of shading, the intensity if below a specific level.
- Check the connector for any fault
in connection. - Replace the scanning
lamp.
- Replace the inverter PCB. - Replace the reader controller PCB.
0002 ADFThe intensity is below a specific level between sheets (ADF).
E227 there is an error in the power supply (24 V).
0001 At power-on, the 24-V port is
OFF.
0002 At the start of a job, the 24-V
port is OFF.
0003 At the end of a job, the 24-V
port is off.
0004 When a load is driven, the 24-V
port isOFF.
- Check the connector for any fault
in connection. - Replace the power
supply.
E240 The communication
between the main controller PCB and the DC controller PCB is faulty.
0000 There is an error in the communication between the main controller PCB
and the CPU of the DC controller PCB.
- Check the connector for any fault
in connection.
- Replace the DC controller PCB. - Replace the main controller PCB.
E248 There is an EEPROM
error.
0001 An error has occurred at power-on.
0002 An error has occurred at time of writeoperation.
0003 An error has occurred at time of read
operation after write operation