E514 -8001 -05 Title a. Error in assist operation (Finisher-Q1)
b. Error in the Gripper Base Motor (Finisher-N1)
Detection description
a. Assist HP sensor does not come ON within 5 sec after the assist motor starts operation.
b. The gripper does not come off the Gripper Base Rear Sensor when the Gripper Base Motor has been driven for 3 seconds.
Remedy a-1. Connector of assist HP sensor
a-2. Connector of assist motor
a-3. Replacement of assist HP sensor
a-4. Replacement of assist motor
a-5. Replacement of finisher controller PCB
b-1. The connector of the Gripper Base Rear Sensor (S117) or  the Gripper Base Motor (M116) are disconnected.
b-2. The wiring of the Gripper Base Rear Sensor (S117) or the Gripper Base Motor (M116) are faulty.
b-3. The Gripper Base Rear Sensor (S117) is faulty.
b-4. The Gripper Base Motor (M116) is faulty.
b-5. The Finisher Controller PCB is faulty.
E514 -8002 -05 Title a. Error in assist operation (Finisher-Q1)
b. Error in the Gripper Base Motor (Finisher-N1)
Detection description
a. Assist HP sensor does not go OFF within 5 sec after the assist motor starts operation.
b. The Gripper Base Rear Sensor dose not detect the gripper when the Gripper Base Motor has been driven for 3 seconds.
Remedy a-1. Connector of assist HP sensor
a-2. Connector of assist motor
a-3. Replacement of assist HP sensor
a-4. Replacement of assist motor
a-5. Replacement of finisher controller PCB
b-1. The connector of the Gripper Base Rear Sensor (S117) or the Gripper Base Motor (M116) are disconnected.
b-2. The wiring of the Gripper Base Rear Sensor (S117) or the Gripper Base Motor (M116) are faulty.
b-3. The Gripper Base Rear Sensor (S117) is faulty.
b-4. The Gripper Base Motor (M116) is faulty.
b-5. The Finisher Controller PCB is faulty.
E514 -8003 -05 Title Error in the Gripper Motor (Finisher-N1)
Detection description The gripper does not come off the Gripper HP Sensor when
the Gripper Motor has been driven for 3 seconds.
Remedy 1. The connector of the Gripper HP Sensor (S140) or the Gripper Motor (M117) are disconnected.
2. The wiring of the Gripper HP Sensor (S140) or the Gripper Motor (M117) are faulty.
3. The Gripper HP Sensor (S140) is faulty.
4. The Gripper Motor (M117) is faulty.
5. The Finisher Controller PCB is faulty.
E514 -8004 -05 Title Error in the Gripper Motor (Finisher-N1)
Detection description The Gripper HP Sensor does not detect the gripper when the
Gripper Motor has been driven for 3 seconds.
Remedy
1. The connector of the Gripper HP Sensor (S140) or the Gripper Motor (M117) are disconnected.
2. The wiring of the Gripper HP Sensor (S140) or the Gripper Motor (M117) are faulty.
3. The Gripper HP Sensor (S140) is faulty.
4. The Gripper Motor (M117) is faulty.
5. The Finisher Controller PCB is faulty.
E514 -8005 -05 Title Error in the Gripper Motor (Finisher-N1)
Detection description The gripper does not come off the Position Sensor when the
Gripper Motor has been driven for 3 seconds.
Remedy
1. The connector of the Gripper Position Sensor (S115) or the Gripper Motor (M117) are disconnected.
2. The wiring of the Gripper Position Sensor (S115) or the Gripper Motor (M117) are faulty.
3. The Gripper Position Sensor (S115) is faulty.
4. The Gripper Motor (M117) is faulty.
5. The Finisher Controller PCB is faulty.
E514 -8006 -05 Title Error in the Gripper Motor (Finisher-N1)
Detection description The Gripper Position Sensor does not detect the gripper when
the Gripper Motor has been driven for 3 seconds.
Remedy
1. The connector of the Gripper Position Sensor (S115) or the Gripper Motor (M117) are disconnected.
2. The wiring of the Gripper Position Sensor (S115) or the Gripper Motor (M117) are faulty.
3. The Gripper Position Sensor (S115) is faulty.
4. The Gripper Motor (M117) is faulty.
5. The Finisher Controller PCB is faulty.
E518 -8001 -05 Title Error in Folding Feed Motor lock (Paper Folding Unit-H1)
Detection description The lock signal turns on for the specified time from the drive
start of Folding Feed Motor.
Remedy 1. Connector of the Folding Feed Motor (M11) is disconnected.
2. Folding Feed Motor (M11) is faulty
E530 -8000 -05 Title Error in the Front or Rear Alignment Motor (Finisher-N1)
Detection description The Front or Rear Alignment Motor operate abnormally during
initialization.
Remedy 1. The connector of the Front/Rear Alignment HP Sensor (S108/S109) or the Front/Rear Alignment Motor (M108/ M109) are disconnected.
2. The wiring of the Front/Rear Alignment HP Sensor (S108/S109) or the Front/Rear Alignment Motor (M108/M109) arefaulty.
3. The Front/Rear Alignment HP Sensor (S108/S109) is faulty.
4. The Front/Rear Alignment Motor (M108/M109) is faulty.
5. The Finisher Controller PCB is faulty.
E530 -8001 -05 Title a. Error in front alignment motor (Finisher-Q1)
b. Error in the Front Alignment Motor (Finisher-N1)
Detection description a. Front alignment guide HP sensor does not go OFF within 5
sec after the front alignment motor starts operation.
b. The front alignment plate does not come off the Front Alignment HP Sensor when the Front Alignment Motor has been driven for 4 seconds.
Remedy a-1. Connector check of front alignment guide HP sensor
a-2. Connector check of front alignment motor
a-3. Replacement of front alignment guide HP sensor
a-4. Replacement of front alignment motor
a-5. Replacement of finisher controller PCB
b-1. The connector of the Front Alignment HP Sensor (S108) or the Front Alignment Motor (M108) are disconnected.
b-2. The wiring of the Front Alignment HP Sensor (S108) or the Front Alignment Motor (M108) are faulty.
b-3. The Front Alignment HP Sensor (S108) is faulty.
b-4. The Front Alignment Motor (M108) is faulty.
b-5. The Finisher Controller PCB is faulty
E530 -8002 -05 Title a. Error in alignment operation (Finisher-Q1)
b. Error in the Front Alignment Motor (Finisher-N1)
Detection description a. Rear alignment guide HP sensor does not go OFF within 5
sec after the rear alignment motor starts operation.
b. The Front Alignment HP Sensor does not detect the Front Alignment plate when the Front Alignment Motor has been driven for 4 seconds.
Remedy a-1. Connector of rear alignment guide HP sensor
a-2. Connector of rear alignment motor
a-3. Replacement of rear alignment guide HP sensor
a-4. Replacement of rear alignment motor
a-5. Replacement of finisher controller PCB
b-1. The connector of the Front Alignment HP Sensor (S108) or the Front Alignment Motor (M108) are disconnected.
b-2. The wiring of the Front Alignment HP Sensor (S108) or the Front Alignment Motor (M108) are faulty.
b-3. The Front Alignment HP Sensor (S108) is faulty.
b-4. The Front Alignment Motor (M108) is faulty.
b-5. The Finisher Controller PCB is faulty.
E531 -8002 -05 Title a. Error in staple (Finisher-Q1) b. Error in the Staple Motor (Finisher-N1)
Detection description a. Staple HP sensor does not go OFF within 500 msec after
the staple motor starts operation.
b. The Staple HP Sensor does nor detect the staple unit when
the Staple Motor has been driven for 400 msec.
Remedy a-1. Connector check of staple unit
a-2. Replacement of staple unit
a-3. Connector check of staple HP sensor
a-4. Replacement of staple HP sensor
a-5. Replacement of finisher controller PCB
b-1. The connector of the staple unit is disconnected.
b-2. The wiring of the staple unit is faulty.
b-3. The staple unit is faulty.
b-4. The Finisher Controller PCB is faulty.
E532 -8000 -05 Title Error in the Staple Shift Motor (Finisher-N1)
Detection description The Staple Shift Motor operate abnormally during initialization.
Remedy 1. The connector of the Stapler Shift HP Sensor (S107) or the
Staple Shift Motor (M107) are disconnected.
2. The wiring of the Stapler Shift HP Sensor (S107) or the Staple Shift Motor (M107) are faulty.
3. The Stapler Shift HP Sensor (S107) is faulty.
4. The Staple Shift Motor (M107) is faulty.
5. The Finisher Controller PCB is faulty.
E532 -8001 -05 Title a. Error in staple slide (Finisher-Q1) b. Error in the Stapler Shift Motor (Finisher-N1)
Detection description
a. Staple HP sensor does not come ON within 500 msec after the staple shift motor starts operation.
b. The staple unit does not come off the Stapler Shift HP Sensor when the Staple Shift Motor has been driven for 5 seconds.
Remedy a-1. Connector check of staple shift motor
a-2. Replacement of staple shift motor
a-3. Connector check of staple HP sensor
a-4. Replacement of staple HP sensor
a-5. Replacement of finisher controller PCB
b-1. The connector of the Stapler Shift HP Sensor (S107) or the Staple Shift Motor (M107) are disconnected.
b-2. The wiring of the Stapler Shift HP Sensor (S107) or the Staple Shift Motor (M107) are faulty.
b-3. The Stapler Shift HP Sensor (S107) is faulty.
b-4. The Staple Shift Motor (M107) is faulty.
b-5. The Finisher Controller PCB is faulty.
E532 -8002 -05 Title a. Error in staple slide (Finisher-Q1) b. Error in the Stapler Shift Motor (Finisher-N1)
Detection description
a. Staple HP sensor does not go OFF within 500 msec after the staple shift motor starts operation.
b. The Stapler Shift HP Sensor does not detect the staple unit when the Staple Shift Motor has been driven for 5 seconds.
Remedy a-1. Connector check of staple shift motor
a-2. Replacement of staple shift motor
a-3. Connector check of staple HP sensor
a-4. Replacement of staple HP sensor
a-5. Replacement of finisher controller PCB
b-1. The connector of the Stapler Shift HP Sensor (S107) or the Staple Shift Motor (M107) are disconnected.
b-2. The wiring of the Stapler Shift HP Sensor (S107) or the Staple Shift Motor (M107) are faulty.
b-3. The Stapler Shift HP Sensor (S107) is faulty.
b-4. The Staple Shift Motor (M107) is faulty.
b-5. The Finisher Controller PCB is faulty.
E535 -0001 -05 Title Error in the Swing Guide Motor (Finisher-N1)
Detection description The swing guide does not come off the Swing Guide HP
Sensor when the Swing Guide Motor has been driven for 3 seconds.
Remedy 1. The connector of the Swing Guide HP Sensor (S110) or the Swing Guide Motor (M110) are disconnected.
2. The wiring of the Swing Guide HP Sensor (S110) or the Swing Guide Motor (M110) are faulty.
3. The Swing Guide HP Sensor (S110) is faulty.
4. The Swing Guide Motor (M110) is faulty.
5. The Finisher Controller PCB is faulty.
E535 -0002 -05 Title Error in the Swing Guide Motor (Finisher-N1)
Detection description The Swing Guide HP Sensor does not detect the swing guide
when the Swing Guide Motor has been driven for 3 seconds.
Remedy 1. The connector of the Swing Guide HP Sensor (S110) or the Swing Guide Motor (M110) are disconnected.
2. The wiring of the Swing Guide HP Sensor (S110) or the
Swing Guide Motor (M110) are faulty.
3. The Swing Guide HP Sensor (S110) is faulty.
4. The Swing Guide Motor (M110) is faulty.
5. The Finisher Controller PCB is faulty.
E535 -0003 -05 Title Error in the Swing Guide Motor (Finisher-N1)
Detection description The Swing Guide Height Detection Sensor failed to be ON
even though specified period of time has passed when lowering the swing guide.
Remedy 1. The connector of the Swing Guide Height Detection Sensor (S118) or the Swing Guide Motor (M110) are disconnected.
2. The wiring of the Swing Guide Height Detection Sensor (S118) or the Swing Guide Motor (M110) are faulty.
3. The Swing Guide Height Detection Sensor (S118) is faulty.
4. The Swing Guide Motor (M110) is faulty.
5. The Finisher Controller PCB is faulty.
E535 -0004 -05 Title Error in the Swing Guide Motor (Finisher-N1)
Detection description The Swing Guide Height Detection Sensor failed to be OFF
even though specified period of time has passed when raising the swing unit.
Remedy 1. The connector of the Swing Guide Height Detection Sensor
(S118) or the Swing Guide Motor (M110) are disconnected.
2. The wiring of the Swing Guide Height Detection Sensor (S118) or the Swing Guide Motor (M110) are faulty.
3. The Swing Guide Height Detection Sensor (S118) is faulty.
4. The Swing Guide Motor (M110) is faulty.
5. The Finisher Controller PCB is faulty.
E535 -8001 -05 Title Error in swing guide motor
Detection description Swing guide HP sensor does not come ON within 2 sec after
the swing guide motor starts operation.
Remedy 1. Connector check of swing guide motor
2. Replacement of swing guide motor
3. Connector check of swing guide HP sensor
4. Replacement of swing guide HP sensor
5. Replacement of finisher controller PCB
E535 -8002 -05 Title Error in swing guide motor
Detection description Swing guide HP sensor does not go OFF within 2 sec after the
swing guide motor starts operation.
Remedy 1. Connector check of swing guide motor
2. Replacement of swing guide motor
3. Connector check of swing guide HP sensor
4. Replacement of swing guide HP sensor
5. Replacement of finisher controller PCB
E537 -8001 -05 Title a. Error in front alignment motor (Finisher-Q1)
b. Error in the Rear Alignment Motor (Finisher-N1)
Detection description
a. Front alignment guide HP sensor does not come ON within 5 sec after the front alignment motor starts operation.
b. The rear alignment plate does not come off the Rear Alignment HP Sensor when the Rear Alignment Motor has been driven for 4 seconds.
Remedy a-1. Connector check of front alignment guide HP sensor
a-2. Connector check of front alignment motor
a-3. Replacement of front alignment guide HP sensor
a-4. Replacement of front alignment motor
a-5. Replacement of finisher controller PCB
b-1. The connector of the Rear Alignment HP Sensor (S109) or the Rear Alignment Motor (M109) are disconnected.
b-2. The wiring of the Rear Alignment HP Sensor (S109) or the Rear Alignment Motor (M109) are faulty.
b-3. The Rear Alignment HP Sensor (S109) is faulty.
b-4. The Rear Alignment Motor (M109) is faulty.
b-5. The Finisher Controller PCB is faulty.
E537 -8002 -05 Title a. Error in alignment operation (Finisher-Q1)
b. Error in the Rear Alignment Motor (Finisher-N1)
Detection description
a. Rear alignment guide HP sensor does not come ON within
5 sec after the rear alignment motor starts operation.
b. The Rear Alignment HP Sensor does not detect the rear alignment plate when the Rear Alignment Motor has been driven for 4 seconds.
Remedy a-1. Connector of rear alignment guide HP sensor
a-2. Connector of rear alignment motor
a-3. Replacement of rear alignment guide HP sensor
a-4. Replacement of rear alignment motor
a-5. Replacement of finisher controller PCB
b-1. The connector of the Rear Alignment HP Sensor (S109)
or the Rear Alignment Motor (M109) are disconnected.
b-2. The wiring of the Rear Alignment HP Sensor (S109) or the Rear Alignment Motor (M109) are faulty.
b-3. The Rear Alignment HP Sensor (S109) is faulty.
b-4. The Rear Alignment Motor (M109) is faulty.
b-5. The Finisher Controller PCB is faulty.
E539 -8001 -05 Title Error in delivery angle adjustment motor (HP sensor delay)
Detection description HP sensor does not come ON within 5 sec after the operation
start.
Remedy 1. Connector check of delivery angle HP sensor
2. Connector check of delivery angle adjustment motor
3. Replacement of delivery angle HP sensor
4. Replacement of delivery angle adjustment motor
5. Replacement of finisher controller PCB
E539 -8002 -05 Title Error in delivery angle adjustment motor (HP sensor stationary)
Detection description HP sensor does not go OFF within 5 sec after the operation
start.
Remedy 1. Connector check of delivery angle HP sensor
2. Connector check of delivery angle adjustment motor
3. Replacement of delivery angle HP sensor
4. Replacement of delivery angle adjustment motor
5. Replacement of finisher controller PCB